Home
Search waterheatertimer.org / all results |
Gas water heater repair manuals |
Back
to 10 things for troubleshooting water heater For atmospheric vent models Range Low 55° - very hot 160° Average bath 110°F, typical water heater temp 120° ECO limit 199° F, ECO trips, gas valve fails TP release water at 170° All calibrations are approximate Severe scalding risk over 135° To reset gas control, rotate dial to OFF, wait 10 minutes for gas to clear. Then relight. Buy Reliance/ Honeywell gas control American / Honeywell gas control Kenmore water heater gas valve Craftmaster/ Whirlpool Bradford White AO Smith Honeywell gas control at Amazon American / Honeywell gas control at Amazon Honeywell gas valve for propane Honeywell natural gas valve Reliance NG at Amazon Reliance LP at Amazon Kenmore water heater gas valve> Gas water heater timer fits this valve Replacement instructions How to test & replace Honeywell/ pdf WT8840 replacement manual How to replace Honeywell gas control valve Resources WV8840/ WT8840: Typical installation manual Typical installation manual/ low NOx Adjust temp on Honeywell gas valve Error codes WV8840 series Error codes WV8840 series Error codes WT8840 AO Smith service handbook Service handbook State Error code/ troubleshoot/ service manual/ FVIR Bradford White service manual Error light blinking 4 times How to light water heater How to light water heater/ pdf How to light Whirlpool energy smart WT8840 product overview models WT8840 gas valve manual and troubleshoot How to replace gas control valves How to test gas control valve How to install gas water heater |
For power vent and flue dampered models Range Low 90° - very hot 160° Average bath 110°F, typical water heater temp 120° ECO limit 199°F, ECO trips, gas valve fails Average bath 110°F ECO limit 199°F TP release water at 170° Buy Example Honeywell gas control valve at Amazon Reliance NG at Amazon Replacement instructions How to replace water heater gas valve Resources: Flue dampered service manual/ atmospheric Flue dampered/general install and troubleshoot Dampered troubleshoot codes Dampered error codes Dampered error codes Induced draft troubleshoot codes Example dampered install manual2 Example power vent install manual Example power vent install manual Example power direct vent install manual Adjust temperature/ error codes on Honeywell How to light Honeywell gas valve Error codes and troubleshoot chart Error codes Error codes Icon gas valve error codes AO Smith service handbook Bradford White power vent service manual 1 Bradford White power-vent service manual 2 Bradford power-direct-vent service manual Condensing power vent service manual Test gas control/ from BW service manual Sequence of operation How to clean burner Safety Water heater safety precautions Water heater precautions/ pdf Gas-water-heater-Safety-Precautions Gas valve safety Thermal expansion Insulation blanket |
For power vent models Range Low 80° to Hot 150° Error C flashes at 160° Buy Buy Intellivent gas control at Amazon White Rodgers/ Rheem Intellivent gas control AO Smith intellivent AO Smith Intellivent at Amazon AO Smith White Rodgers at Amazon Replacement instructions How to replace water heater gas valve Resources: How to light water heater Typical installation manual Sample installation manual Example install manual Ultra low nox power vent manual Error codes and adjust temp on Intelli-vent AO Smith Intellivent troubleshoot and FV test Troubleshoot Intellivent/ pdf FVIR intellivent troubleshoot .pdf Intellivent service manual TC-048 R6 Sequence of operation and service brief Intellivent wiring Power direct vent troubleshoot Status codes and troubleshoot/ condensing How to reset intellivent For resetting controller: Method A... After the unit has been off for at least a minute, plug it in, turn on switch; within a few seconds, depress both arrow buttons on controller, and hold them until the left light begins to blink. Release them, and within a few seconds, push those arrow buttons in the following sequence: L/R/L/L/R/L/R/R. This should reset the controller. Method B... after FV event on AO Smith 1. Turn off power to water heater for 10 seconds. 2. Restore power to water heater. 3. Within 10 seconds of restoring power, press the two temperature adjust buttons simultaneously until the left (green) “Vacation” LED begins to blink (approx. 5 second delay). Once the Vacation LED begins to blink, release both buttons. 4. Again, within 10 seconds, press both temperature adjust buttons simultaneously until Vacation LED is on steady (approx. 5 second delay). 5. Release two buttons, the microcomputer will clear the FVS lock-out and normal operation will then be restored. |
Buy: Camco White Rodgers at Amazon Resources: Troubleshooting/ pdf How to light gas water heater How to replace water heater gas valve Buy: Buy universal gas control wrench |
Larger image Buy Gas control valve thermostats at Amazon Gas water heater thermostats at Amazon Rheem gas control valve at Amazon Gas control valve at Amazon Camco White Rodgers at Amazon Gas water heater timer fits this valve Replacement instructions How to replace water heater gas valve Resources: Installation manual water heater w White Rodgers Troubleshoot guidelines/ ultra low nox Service manual Service manual 2 Service manual 3 Operation and safety How to light water heater/pdf General troubleshoot manual /pdf White Rodgers gas control valve replacement pdf Power vent water heater issues Magnet testing Test thermocouple Gas valve testing How to light gas water heater White Rodgers NG replace, install, set temp |
Honeywell Smart Valve Larger image Resources: Temperature settings and features Smart valve error codes Service manual Service manual 2 Install smart valve & troubleshoot |
Robertshaw Natural gas Buy Robert Shaw natural gas RS Natural gas at Amazon Camco RS at Amazon Gas water heater timer fits this valve |
Buy Gas water heater thermostats at Amazon Robert Shaw natural gas Robert Shaw propane gas Replacement instructions How to replace water heater gas valve Resources: Robert Shaw models Robert shaw service manual/ pdf Robert Shaw/ Unitrol troubleshooting/ pdf General troubleshoot/ pdf General troubleshoot manual /pdf How to light water heater/pdf Magnet testing Test thermocouple Gas valve testing Operation and safety Recalibrate gas control/ pdf How to light gas water heater Adjust pilot on unitrol gas control valve How to test White Rodgers gas valve p14 How to test Honeywell Icon gas valve p23 How to test Robertshaw gas valve p14 |
Atwood gas control valve Fits all Atwood water heater that have a pilot light Buy Atwood gas control valve at Amazon Atwood parts at Amazon Atwood water heaters and parts at Amazon Resource: How to replace gas control valve thermostat Atwood water heater troubleshoot resources Suburban water heater service manual |
Honeywell immersion thermostat 12-277 volt AC SPST controller 12-48 volt DC Add to any hot water tank Surface mount or immersion into tank Temperature range: 100-180°F Water over 135° poses extreme danger of scalding. Add mixing valve. Buy Honeywell/ Rheem SP11798B Honeywell L4006 Line Voltage Mechanical Thermostats Resources: Add another thermostat to gas or electric water heater Advantages-disadvantages mixing valve Control recirculation pump using controller L4006 manual L4006 wiring illustration Honeywell L8104 water heater controller |
SIT gas control valve for water heater How to light and set temperature SIT gas control Kenmore with power anode rod How to light Effex water heater Effex service manual Suburban water heater service manual Whirlpool energy smart gas water heater manual |
Robert Shaw 120Volt input gas control valve Wiper Control and Gas Valve assembly Triangle pointed upward is 120 degrees F Replacement for Rheem power vent/ Buy Rheem wiper SP20123A thermostat KIT Wiper SP20123B valve/ no thermostat Resources Larger image Error Codes and troubleshoot Guardian power vent Robert Shaw error code Check the blower motor, gas control etc Rheem parts list American power flex parts General manual with lighting instructions Replace water heater gas control and FV Check pressure switch, blower, gas control Sequence of operation How to light water heater To reset: turn the red control knob on and off 6 times within 30 seconds to reset the board. |
14 things needed for gas water heater & .pdf resources | |
What you need for
operation of gas water heater. General troubleshoot 1) Basic parts and operation 2) Adequate incoming air supply ... issues: closed doors, tightly insulated house, very hot attic. 3) Adequate air supply getting to burner... issues: dirty vent screen, dirty environment, maintenance. 4) Thermal cutoff ... TCO ... issues: failed part, maintenance, vent. 5) Flammable vapor lockout .... issues: exposure to vapors, bad FV sensor, failed FV system, 6) Fuel supply to gas valve thermostat ... natural gas and propane are different ... issues: wrong gas, low pressure, moisture in pipe, undersized gas meter, supply line too small for BTU rating. 7) Gas valve thermostat regulates fuel supply ... issues: not enough gas, failed thermostat, failed gas control valve. 8) Fuel supply from thermostat to burner ... issues: maintenance, thermocouple-thermopile, gas control valve. 9) Clean and replace burner ... issue: periodic maintenance requires burner inspection, cleaning, and possible replacement 10) Functioning thermopile-thermocouple-pilot light ... issues: misalignment, failure of part. 11) Ignition of fuel supply by pilot light or hot surface igniter ... issues: pilot light, piezo igniter, electrode. 12) Power vent water heater troubleshoot ... issues: pressure switch, blower, blower sequence from gas control, outlet polarity 13) Venting combustion byproduct .... issues: vent in disrepair, other vents in house drawing air 14) Misc troubleshoot manuals 15) How to install gas water heater 16) How to maintain water heater |
Support
the economy: Buy water heaters from my associate links: 50 gallon Gas water heaters at Amazon 40 gallon gas water heaters at Amazon 50 gallon Electric water heaters at Amazon 40 gallon electric water heaters at Amazon Hybrid / heat pump/ water heaters at Amazon Resources: How to install gas water heater How to install electric water heater Troubleshoot gas water heater Troubleshoot electric water heater Point of use water heaters |
|
|
|
||||||
Contactors/ relays |
|
|
||||||
|
|
|
Buy Electronic parts Industrial supplies Tools and home improvement Home and garden Hayward pool Pentair pool Southwire electric |
|
Buy
Tools DEWALT Black and Decker Stanley SKIL Makita Porter-Cable Bosch Irwin Hand tools Klein hand tools Fluke electrical testing Dremel hobby tools Campbell Hausfeld air powered Tekton automotive Powerbuilt automotive Saws and saw blades |
|
Resource: Compare box timers DPDT timers Intermatic Control water heater w/ Z-wave |
|
Resource: Intermatic control centers: and parts Digital control centers and parts Tork control centers and parts Subpanels All control centers and parts Enclosures |
|
Resource: Programmable timers Countdown timers Off delay timers On delay timers Timer modules Din rail Twin & one-shot Woods Intermatic Tork |
|
Recirculation systems |
Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |