Compare 16 electric and 2 gas water heater timers | Try a water heater timer free | Figure Volts Amps Watts for water heater | 9 ways to save with water heater | Troubleshoot electric water heater | Do-it-yourself | ||
| ||||||||
|
Compare
box-type water heater
timers |
|
|
![]() |
EH40 30 amp digital Programmable Intermatic 30 amp 601571 > 240 Volt water heater timer >7-day programmable > 7 TOTAL PROGRAMS > days of the week can be different > no memory loss with power outage > 3-year back-up battery > external override > 1 minimum on-off times 240V EH40 manual 120V EH10 manual Manual for 120V ET171 EH40 at Grainger 240 Volt ET171 at Grainger 120 Volt
|
|||||
|
|
||||||
|
See all Tork timers Tork EW103B 7-day digital Programmable > 120 Volt or 240 Volt water heater timer > 20 set points per week > each day can be different > 1 minute minimum > Capacitor back-up: no memory loss with power outage Tork EW103B at Lowes Tork EW103B at Grainger EW103B wiring diagram for 240V water heater E-EW100B wiring manual EW100B sales sheet with models and wiring EW series instruction/programming manual |
|||||
|
|
||||||
SA series at Amazon |
Sylvania Timers SA 315 40 Amp 240 Volt clock/ 240Volt circuit DPST Indoor/outdoor SA 307 40 Amp 240 Volt clock/ 240Volt circuit DPST Indoor SA 300 40 Amp 120 Volt clock/ 120Volt circuit SPST Indoor CR2032 batteries. Battery back up holds programming in power outage, metal housing 7-5-2 programming means weekends can be different Sylvania SA300-manual 120V indoor sell sheet wiring Sylvania SA310-manual 120V indoor/outdoor sell sheet wiring Sylvania SA315-manual 240V indoor/outdoor sell sheet wiring Sylvania SA306-manual 120V indoor/outdoor sell sheet wiring Sylvania SA307-manual 240V indoor sell sheet wiring |
|||||
|
|
||||||
|
Paragon timers are discontinued Paragon digital programmable EC4005 Indoor/outdoor models available 120V or 240V 16 set points per week Day skipper, Manual override, Power outage carryover Paragon 4000 series manual Paragon P100 series mechanical timer P-104 mechanical timer for 240V circuits P-101 for 120V circuits P100 Series Manual
|
|||||
|
|
|||
![]() |
WH40
240
Volt mechanical
timer > lift and rotate dial to set clock > reset clock after power outage > attach Mechanical Time Tripper pins on dial to control on-off functions > manual override > cannot set short duration programming less than 1 hour > program times are approximate > each day is same. Use T101 shown below for 120V water heaters
|
||
|
|
|||
![]() Large image of T-104R 240 Volt Indoor-outdoor |
T-104 indoor mechanical
timer
240 Volt T-104R indoor-outdoor mechanical timer 240 Volt Minimum 1 hour on-off > 1-12 on-off per day > lift and rotate dial to set clock > reset clock after power outage > attach Mechanical Time Tripper pins on dial to control on-off functions > manual override so water heater runs continuously > each day is same |
||
|
|
|||
![]() Larger image |
Intermatic
T1906 mechanical 240 Volt T1976 for 240 Volt with day skipper T1905 for 120 Volt Minimum 15 minute on-off periods, 96 operations per day, each day is the same, reset after power outage. SPST timer means 240 V water heater has one leg of live electricity that is not turned off.
|
||
|
|
|||||||||||||||||||||||||||||||||||
![]() |
GE
15132
digital programmable > 120 Volt or 240 Volt water heater timer/ change dip switch to select clock voltage > DPST turns off both hot wires to 240V water heater > Indoor-outdoor > 7 day programmable timer > 9 on-off settings per day > days of the week can be different > back-up battery > no reset after power outage > rotate dial to set time > push dial segments down to set on-off functions > Indicator lights show operation
|
||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||
![]() Large image of 120-240Volt GE 15207 |
GE 15207 mechanical
indoor
timer > 120 Volt or 240 Volt water heater timer/ change dip switch to select clock voltage > DPST turns off both hot wires to 240V water heater > 24 on-off periods per day > Minimum 1/2 hour on-off > each day is same > rotate dial to set time > push dial segments down to set on-off functions > Indicator lights show operation > Reset time dial after power outage
|
||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||
![]() See Larger |
Woods
Indoor-outdoor Water heater timers Woods 59396 <> 120 Volt clock requires neutral wire <> 120V or 240V 30 Amp load > 59396 is SPST > clock motor is 120V > Good for 120 Volt water heaters. > 59399 is DPST > clock motor is 120V > neutral wire needed > 24 on-off periods per day > Minimum 1/2 hour on-off > each day is same > rotate dial to set time > Reset time after power loss See manual Woods 59402 <> use dip switch to choose 120V or 240V clock <> 120V or 240V 40 Amp load > 59402 is DPST > turns off both hot wires to 240V water heater > 59401 is SPST > only turns off one hot wire to 240V water heater > 24 on-off periods per day > each day is same > rotate dial to set time
|
||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
![]() Large image of 120Volt T7401 |
Heavy
duty 7-day
mechanical timers > more expensive than digital programmable
shown
at page top > mechanical timers are simple to set > each
day of
the week can be different > day
skipper > load carryover during power outage >
3
on-off cycles per day > minimum cycle 3.5 hours 240V Intermatic T7402BC 120V Intermatic T7401BC Intermatic PDF manuals for T7401-2 (buy direct from Intermatic) T7401B at WW Grainger T7801B at Grainger Sample manual
|
||||||||||||||||||||||||||||||||||
![]() Larger image | T2000
7-day timer 120V and 208-277V 42 ON 42 OFF per week Minimum ON-OFF 2 hours 6 ON-OFF per day NO NC terminals SPDT Tripper: 156T1950A Snap switch: 133T701A 120V motor: WG720-10D/ 208-277V motor WG723-10D T2000 sell sheet | ||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||
|
Tips
for choosing & installing water heater timer 1. Re-setting timers after power outage is inconvenient, especially when located outdoors after thunderstorm. 2. Check timer has enough on-off periods per day or per week 3.It is difficult to reset timers located in remote locations requiring flashlight, for example in attic or cluttered utility area. 4. Put timer at eye-level In-wall timer is more difficult to install, but gives easy access, and adds value to home. Back to all timers |
![]() |
|||||||||||||||||||||||||||||||||
| http://waterheatertimer.org/images/Man-wiith-coveralls-200.jpg | |||||||||||||||||||||||||||||||||||
![]() |
| ||||||||||||||||||||||||||||||||||
![]() | Family chart for setting water heater timer How to install electric meter on water heater How much does it cost to operate water heater How much does water heater timer save I discovered that the timer caused me to schedule hot water use, and my overall usage declined. Reducing consumption is the key to saving money with any type water heater Off-peak water heater options Troubleshoot electric water heater | ||||||||||||||||||||||||||||||||||
![]() |
E-mail: info@waterheatertimer.org Site map |