Compare
box-type water heater
timers |
|
|
|
EH40 digital Programmable > 240 Volt water heater timer >7-day programmable > 6 on-off per day > max 42 on-off per week > days of the week can be different > no memory loss with power outage > 3-year back-up battery > external override Manuals 240 V EH40 & 120 V EH10 Manual for 120V ET171 EH40 at Grainger 240 Volt ET171 at Grainger 120 Volt How to wire EH40 http://waterheatertimer.org/images/Compare-box-type-timers-156.jpg |
||
|
|
|||
![]() See Larger |
Tork digital Programmable > 120 Volt or 240 Volt water heater timer > Indoor-outdoor > 7 day programmable > 20 on-off per week > no memory loss with power outage Tork EW103B at Lowes Tork EW103B at Grainger EW100 series manual with wiring for 120V and 240V |
||
|
|
|
![]() |
240
Volt WH40
mechanical
timer > lift and rotate dial to set clock > reset clock after power outage > attach Mechanical Time Tripper pins on dial to control on-off functions > manual override > cannot set short duration programming less than 1 hour > program times are approximate > each day is same. Use T1905 for 120V water heaters Intermatic manuals WH40 & WH21 Intermatic manual for T1905 WH40 at Grainger WH40 at Lowes T1905 at Grainger How to wire WH40 additional Mechanical Time Tripper Pins type1 type2 |
|
|
|
![]() Larger image of T-104 |
T-101 series 240 Volt
indoor-outdoor mechanical timer > lift and rotate
dial to set
clock > reset clock after power outage >
attach Mechanical Time Tripper pins on dial to control
on-off functions > manual override so water heater runs
continuously > each day is same Intermatic PDF manual for T-104 T-104R at Grainger T-101 at Lowes Tork 1101-0 at Lowes |
|
|
|||||||
![]() |
GE
15132
digital programmable > 120 Volt or 240 Volt water heater timer > Indoor-outdoor > 7 day programmable timer > 9 on-off settings per day > days of the week can be different > back-up battery > no reset after power outage > rotate dial to set time > push dial segments down to set on-off functions > Indicator lights show operation See manual for 15132 How to wire 15132 15132 at Home Depot |
||||||
|
|
|||||||
![]() Large image of 120-240Volt GE 15207 |
GE 15207 mechanical
indoor
timer > 120 Volt or 240 Volt water heater timer > 24 on-off periods per day > each day is same > rotate dial to set time > push dial segments down to set on-off functions > Indicator lights show operation See manual for 15207 How to wire GE indoor 15207 How to wire GE indoor/outdoor 15087 15207 at Home Depot 15207 at Jasco |
||||||
|
|
|||||||
![]() Large image of 120Volt T7401 |
Heavy
duty 7-day
mechanical timers > more expensive than digital programmable
shown at page top > mechanical timers are simple to set >
each day of
the week can be different > day
skipper > load carryover during power outage >
3
on-off cycles per day > minimum cycle 3.5 hours 240V Intermatic T7402BC 120V Intermatic T7401BC Intermatic PDF manuals for T7401-2 T7401B at WW Grainger
|
||||||
|
|
|||||||
|
Tips
for choosing & installing water heater timer 1. Re-setting timers after power outage is inconvenient, especially when located outdoors after thunderstorm. 2. Check timer has enough on-off periods per day or per week 3. Men install timers, but women are involved and don't like remote locations requiring flashlight. 4. Put timer at eye-level In-wall timer harder to install, but gives easy access any time. In-wall adds value to home. Back to all timers |
![]() |
|||||
| Did I forget your favorite timer? | |
| E-mail: info@waterheatertimer.org | |