|
Intermatic
ET series timers/ 2023 E-mail: geno03245w@gmail.com |
ET2805 timer Larger image ET2805 Larger image ET2825 |
ET2800 series astro timer
or
programmable/
New model Replaces ET8000 series Select 365 day or 7 day mode Rated for LED, motors etc 2 year warranty .... this works for dawn-dusk operation with up to 50 vacation schedules, 2 second pulse (bell ringing), or up to 96 on-off operations with 1 minute minimum USB port for saving programs 1 or 2 circuit options: 2 circuit timer means 2 independent circuits can be operated with separate programs for each/ 1 circuit means timer can operate 1 circuit with same program Auto-detect voltage 120 thru 277 60Hz/ automatic daylight savings 30 amp/ max 8 ga wire, min 14 gauge wire/ use solid copper wire only -40° to 140°F 100 hour back up/ no batteries needed Buy; ET2805C/ steel indoor box/ 30 amp/ SPST ET2815C/ Steel indoor box/ 30 amp/ SPDT Resources: Sell sheet with model numbers ET2800 series vs discontinued ET8000 series ET2805 technical data ET2815 Technical data ET2825 Technical data ET2845 Technical data ET2805 1 circuit manual ET2815 1 circuit Manual 20 amp ET2825 1-2 circuit manual ET2845 2-4 circuit manual |
ET2105 timer Larger image ET2105 Larger image ET2125 |
ET2100 series 24 hour daily timer New model Replaces ET1100 series Rated for LED, motors etc 2 year warranty for workmanship and materials ....up to 96 on-off operations with 50 holiday schedules over 365 day calendar year 1 minute minimum. No pulse or bell ringing capability USB port for saving programs 1 or 2 circuit options: 2 circuit timer means 2 independent circuits can be operated with separate programs for each/ 1 circuit means timer can operate 1 circuit with same program Auto-detect voltage 120 thru 277 60Hz/ automatic daylight savings 30 amp/ max 8 ga wire, min 14 gauge wire/ use solid copper wire only -40° to 140°F 100 hour back up/ no batteries needed Buy; ET2105C/ steel indoor box/ 30 amp/ SPST / 1 circuit Resources: Sell sheet ET2105 Technical data ET2115 Technical data ET2125 1-2 circuit Technical data ET2145 2-4 circuit Technical data ET2105 1-circuit manual ET2115 1-circuit manual ET2125 1-2 circuit manual ET2145 2-4 circuit manual |
ET2745 2-4 circuit timer Larger image ET2705 Larger image ET2725 Larger image ET2745 |
ET2700 series 7 day weekly timer New model Replaces ET1700 series Rated for LED, motors etc 2 year warranty for workmanship and materials ....up to 96 on-off operations with 50 holiday schedules over 365 day calendar year 1 minute minimum. No pulse or bell ringing capability USB port for saving programs 1 or 2 circuit options: 2 circuit timer means 2 independent circuits can be operated with separate programs for each/ 1 circuit means timer can operate 1 circuit with same program Auto-detect voltage 120 thru 277 60Hz/ automatic daylight savings 30 amp contacts/ max 8 ga wire, min 14 gauge wire/ use solid copper wire only -40° to 140°F 100 hour back up/ no batteries needed Buy; ET2705C/ steel indoor box/ 30 amp/ SPST / 1 circuit ET2715C/ steel indoor box/ 30 amp/ SPDT / 1 circuit Resources: Sell sheet ET2705 Technical data ET2715 Technical data ET2725 1-2 circuit Technical data ET2745 2-4 circuit Technical data ET2705 1-circuit manual ET2715 1-circuit manual ET2725 1-2 circuit manual ET2745 2-4 circuit manual |
Steel indoor box Larger image |
DT101D89 20 amp/
24 hour timer 1 model only Nema1 indoor enclosure, DPST or 2X SPST 1 year warranty for manufacturing defects and failure caused by defect Up to 28 on-off events per 24 hour period / minimum 1 minute/ maximum 23 hours 59 minutes/ Programs held in memory during power loss using 2 AAA batteries Automatic DST daylight savings time adjustment Arrives with default 120Volt, or choose another voltage using selector switch for 208, 240, 277V/ Rating 1 HP @ 120V, 1.5 Hp @ 208V, 2 Hp @ 240V #14-#12 AWG wire Buy: ET1105C Steel indoor box/ 30 amp ET1125C Steel indoor box/ 30 amp/1 or 2 circuit Resources: DT101D89 technical data DT101D89 Series manual with wiring |
ET90115 1 circuit timer Larger image ET90115 ET90215 2 circuit timer Larger image ET90215 |
ET90115 and ET90215 365
day astro
timer or
programmable 1-circuit ET90115/
SPDT
2-circuit ET90215/ SPDT 365 day with 2000 set points + holiday schedules/ minimum 1 second 3 year warranty on material or manfacturing defects. Read Astronomic dawn dusk operation with adjustment times Pulse option for bell-ringing, latching contactor or to turn 1 or more circuits on at specified time, with auto off etc for programming daily on-off schedule. with minimum 1 second, maximum 23 hours and 59 minutes ... Real time remote control via Mobile App Remote connection via Can BUS terminal block pg 7-8 in manual USB port for transferring schedule programs and updating the firmware. Auto-detect voltage 120 thru 277VAC 50-60Hz/ automatic daylight savings 30 amp contacts/ max 8 ga wire, min 14 gauge wire/ use solid copper wire only -40° to 140°F 100 hour back up/ no batteries needed Buy: ET90115C 1 circuit / indoor box/ SPDT ET90215C 2 circuit/ indoor box/ SPDT ET90115CR 2 circuit / 3R outdoor box/ SPDT Resources: ET90000 series Sell sheet ET90000 series specs ET9000 series brochure ET 90000 Sell sheet with wiring and box dimensions ET90115 Technical data ET90215 Technical data ET90000 series manual |
Larger image Larger image ET 90000 series/ 365 day programmable or astronomic dawn-dusk/ 4000 set points SPST 120-277Volt/ 50-60 Hz/ 365 day/ 30 amp 4000 on-off events + Holiday 3 year limited warranty -20 amp NC contact -30 amp NO contact rating SPST/ SPDT/ DPST/ DPDT 350 amp maximum panel load > or use use contactors 4, 8, 12 and 16 circuit models Minimum on-off 1 second. Maximum on-off indefinite Wire size: 20 gauge to 6 gauge (note 6 gauge is rated 60A, but timer contacts are 20-30A) Real time remote control via Mobile App Remote connection via Can BUS terminal block pg 7-8 in manual USB port for transferring schedule programs and updating the firmware. Buy: ET90415CR 4 circuit / indoor box ET90815CR 8 circuit/. indoor box ET91215CR 12 circuit/. indoor box ET91615CR 16 circuit/. indoor box Resources ET9000 instruction Manual ET 90000 Sell sheet with wiring and box dimensions ET 90000 sell sheet with features Firmware update instructions for ET90000 ET90415 technical data 4 circuit ET90815 technical data 8 circuit ET91215 technical data 12 circuit ET91615 technical data 16 circui |
Manual override buttons |
|
Screen and data entry | Larger image |
USB connection located on front face of all ET90000 models | |
Dry NO NC relay terminals
can control any voltage ET 90000 Sell sheet with wiring and box dimensions |
|
Input voltage is
automatically detected when wires are energized on power terminals. Dry relay terminals allow switching of any voltage Another image |
Larger image |
ET91615CR
16 circuit and ET91215CR 12 circuit timers with covers removed, showing power terminals and wiring terminals |
Larger image |
Add more relay terminals Additional 4-circuit relay module can be added to 4, 8, and 12 circuit models ... excluded are the 1 circuit models. "You can add additional four-circuit relay boards to the 4, 8 and 12 circuit model to a maximum of 16 circuits per system. Do not exceed 350 amps maximum panel load." Pg 6-8 in manual Relay upgrade .pdf |
Install batteries on all ET series timers. ET1105 timer has Resource: ET1105 Spec sheet Discontinued product page |
Steel outdoor box Larger image Plastic outdoor box w/ see thru door Larger image |
ET1100
Series/ 24 hour timers 20 amp and 30 amp models/ discontinued 1 year warranty for manufacturing defects and failure caused by defect Up to 28 on-off events per 24 hour period / minimum 1 minute/ maximum 23 hours 59 minutes/ Programs held in memory during power loss using 2 AAA batteries Automatic DST daylight savings time adjustment Temporary or permanent override. Arrives with default 120Volt, or choose another voltage using jumper to select 208, 240, 277V/ Rating 1 HP @ 120V, 1.5 Hp @ 208V, 2 Hp @ 240V #18-#10 AWG wire 1 circuit models ET1105 and ET1115 1 or 2 circuit ET1125 offers 1 or 2 circuit operation Choose simultaneous or independent operation on ET1125 using jumper Pulse or bell ringing or latching operation on ET1125 using jumper aka Intermatic 109071 timer Buy: ET1105C Steel indoor box/ 30 amp ET1125C Steel indoor box/ 30 amp/1 or 2 circuit Resources: Sell sheet with model numbers and features ET1105 technical data ET1100 Sell sheet with conversion number from older ET100 series ET1100 Series manual with wiring How to wire ET series timers |
Steel outdoor box Plastic outdoor box w/ see thru door Larger image |
ET1700 Series/ 7-day timers 20 amp and 30 amp models/ discontinued 1 year warranty for manufacturing and materials defects and failure caused by defect Up to 28 on-off events / minimum 1 minute programming/ Programs held in memory during power loss using two AAA batteries Automatic DST daylight savings time adjustment Temporary or permanent override. Arrives with default 120Volt, or choose another voltage using jumper to select 208, 240, 277V/ Rating 1 HP @ 120V, 1.5 Hp @ 208V, 2 Hp @ 240V #18-#10 AWG wire, -40F to +155F 20-30 amp models/ ET1705 series SPST 30 amp, ET1715 SPDT 20 amp 30 amp ET1725 is jumper configurable for 1 or 2 circuit, or pulse output 2 circuit timer means 2 independent circuits can be operated with separate programs for each/ 1 circuit means timer can operate 1 circuit with same program. Buy: ET1705C/ SPST programmable/ ET1715CPD82 Outdoor box w/ see thru door/ 20 amp ET1725C Steel indoor box/ 30 amp / 1 or 2 circuit with option for 2 second pulse/ ET1725CR Steel outdoor box/ 30 amp Resources: ET1700 series sell sheet with model numbers and features ET1705C manual ET1715C manual ET1725C manual How to wire ET series timers |
ET2100 ET2700 ET2800 Sell sheet Manual |
Larger image Another image ET8415 4-circuit astro timer Larger image |
ET8000
Series /7-day astro or programmable 20 amp and 30 amp models/ discontinued 1 year warranty on materials and workmanship 7-day astronomic dawn-dusk timer/ or programmable timer with 28 ON and 28 OFF setpoints 2-second pulse
option (bell ringing, latching contactor etc) with ET8215 models
Minimum set time 1 minute, maximum 6 days, 23 hours, 59 minutesSelectable voltage 120 thru 277 VAC 50-60Hz using jumpers 30 amp contacts/ max 8 ga wire, min 14 gauge wire/ use solid copper wire only/ with five 1/2"-3/4" knockouts -40° to 140°F 2 AAA Battery carryover, with 'Non-volatile memory that protects programnming indefinitely' Sunset ON and programmed OFF options Automatic Daylight Saving Time (DST) 1 and 2 circuit models 2 circuit timer means 2 independent circuits can be operated with separate programs for each/ 1 circuit means timer can operate 1 circuit with same program Buy; ET8015C/ steel indoor box/ 30 amp/ SPST / 1 circuit ET8215C 1-2 circuit with pulse option / indoor Metal box 30 AMP Resources: ET 8000 series sell sheet with wiring ET8015 1-circuit technical data ET8215 1-2-circuit Technical data ET8415 4-circuit Technical data ET8115C 1 circuit manual 20 amp ET8215C 1 or 2 circuit manual How to wire ET series timers ET8415 4-circuit manual with wiring |
fffff |
ET7115 timer manual ET715 timer manual ET716 timer manual ET718 timer manual ET7215 timer manual ET724 timer manual ET728 timer ET7415 timer manual ET799 timer manual |
||
|
|||
ET70215
2-circuit timer 365 day Programmable or astronomic NEMA 1 indoor enclosure Nema 3 outdoor enclosure 7-3/4 x 5 x 3 20 amp rating each pole 1 to 127 second pulse option Timer has Panasonic or Rayovac BR2325 lithium battery that lasts 8 years, and is located next to circuit board. pg 27 in manual. Buy: Intermatic ET70215C 120-208-240-277V BR2325 battery Resources: Sell sheet ET70215 manual |
Larger image |
|
Larger image |
ET171/
discontinued 7-day, 20 set points: 10 ON and 10 OFF, 30 amp Resources for ET171: ET171C manual ET 170 series ET170 series sell sheet Crossover ET171C replace with ET1705C ET171CR (24 volt) replace with ET1705CR ET173C replace with ET1725C ET174C replace with ET1725C ET175C replace with ET1715C |
ET103 timer manual | |
Replace with ET1100 series |
ET100C
24-hour programmable timer Replaced with ET1105 timer (same wiring) 120Volt timer voltage 24-hour digital timer AA backup battery 4 ON and 4 OFF set points Inductive (motor) or incandescent or ballast loads up to 30A Independent SPST relay to control any voltage load. Consumes 3 Watts to operate timer ] 30 amp Buy ET100: ET100C 24-hour timer discontinued Replace with EH10 120 volt timer Resources for ET100C: ET100 series timer ET101C, ET103C ET105C ET100C manual Convert ET 100 series to ET1100 series |
ET104C Selectable voltage: default voltage set for 240Volts 30 amp timer SPDT 6 terminal timer 30 amp Resources: ET102C ET104C manual ET101C ET103C ET105C manual ET104 Manual ET103 timer manual How to program ET104 timer Convert ET100 series to ET1100 series |
|
Larger image |
ET279
timer Model ET279C provides 10-ON 10 OFF operations or momentary contact closures of 1 to 8 seconds (ten each or any combination) for two independent circuits. 30 amp ET279C replace with ET1717C Resources: ET279 manual ET279 sell sheet |
Buy
from my affiliate links every time/ thanks: Amazon ''As an Amazon Associate I earn from qualifying purchases'' Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |