Search Search using google with ads |
Intermatic
control centers and manuals Control panels accept any combinations of T100M, P1353ME, P4243ME or RC2000M or PF1000M Series mechanisms Sell sheet with all model numbers |
Buy Pentair pool Hayward pool Southwire Resources How to wire fireman's switch How to wire 2-speed pool pump |
50-60
amp breaker use 6 gauge / Buy: 6-2 wire Southwire electric tools NMB is house wiring UF is underground |
40-50
amp breaker use 8 gauge / Buy: 8-2 wire Southwire electric tools NMB is house wiring UF is underground |
30
amp breaker use 10 gauge / Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp Southwire electric tools Buy: Spools of ground wire Ground rods |
No busbar or circuit breaker spaces located inside enclosure. Inline fuses can be added: for example .... incoming wire is 6 gauge, and breaker is 60 amp, ... except for timer is 40 amp and 8 gauge. What to do? Add a 600 volt fuse block and 30-40 amp fuse (600 volt rating is code for all residential and commercial wiring ... in other words don't use a boat or automotive fuse). Buy: 600 volt fuseholder 60 amp dual row terminal block Connections must be kept inide enclosure ... use twist on wire connectors. How to wire Intermatic control panels |
T10000R
series/
without breaker slots/ One knockout on the right side for mounting switching device or GFCI. Two combination décor/toggle switch knockouts on the deadfront. Buy: PE10000 enclosure/ no timer/ T10101R with 2x T101 /120V T10004R with T104 /208-240V T10404R with 2x T104 / 208-240V T10604R with T106 and T104 /208-240V for 2-speed pumps T12404R with T104201 and T104/ 208-240V with fireman switch T10004RT3 with transformer T10004RT1 with transformer Resources and manuals T10000R series manual and sell sheet T10404R door label T10604R door label T12404 manual T10101R two T101 timers How to wire and troubleshoot T10404 How to wire and troubleshoot T10604/ with T104 and T106 for 2-speed pump How to wire T12404R with 2 T104 and fireman switch 12" (30.5 cm) high x 12" (30.5 cm) wide with latch x 4-1/4" (10.8 cm) deep Parts sheet Parts appear lower on page |
T21000R
series/ 60 amp/ 4 circuit breaker slots One knockout on the right side for mounting switching device or GFCI. Two combination décor/toggle switch knockouts on the deadfront. 16-3/4" high x 18-7/8" wide x 4-3/8" deep Buy: T21000R enclosure/ no timers/ T20000R with T104 (older design/ smaller 12x12 box) T21001R with T101 /120V T21004R with T104 / 208-240V Resources and manuals 60 amp / Use 6 gauge wire from main breaker box T21000R series manual and sell sheet T20004R manual How to wire T100 series timers How to wire Intermatic control center breaker busbar How to wire control center switch and GFCI How to wire subpanel Parts sheet Parts appear lower on page |
|
T30000R series/ 100 amp/ 8 breaker slots One knockout on the right side for mounting switching device or GFCI. Two combination décor/toggle switch knockouts on the deadfront. 16-1/2" (41.9 cm) high x 10-7/8" (27.6 cm) wide x 4-1/4" (10.8 cm) deep Buy: T30000R enclosure/ no timers/ T30004R with 1 T104 /208-240V T30401R with T104 and T101 / 208-240V and 120V T30404R with 2x T104 / 208-240Volt T30604R with T104 and T106 / 208-240Volt / T32404R with T104201 (T104 with fireman switch) and T104 /208-240V with fireman switch Resources and manuals 100 amp / Use 1 gauge wire 8 circuit breaker slots/ 1" wide push-down breaker T30000R series manual and sell sheet How to wire Intermatic control center breaker busbar How to wire control center switch and GFCI How to wire T30604/ with T104 and T106 How to wire subpanel Parts sheet Parts appear lower on page |
|
T40000R
series/ 125 amp/ 8 circuit breaker
slots One knockout on the right side for mounting switching device or GFCI. Four combination décor/toggle switch knockouts on the deadfront. 20-3/4" (52.7 cm) high x 12-3/4" (32.4 cm) wide x 4-1/4" (10.8 cm) deep Buy: T40000R enclosure/ no timers/ T40004R with T104 / 208-240V T40404R with 2x T104 / 208-240V T40604RT3 with transformer Resources and manuals 125 amp / Use 1 gauge wire 8 circuit breaker slots/ 1" wide push-down breaker T40000R series manual and sell sheet How to wire Intermatic control center breaker busbar How to wire control center switch and GFCI How to wire subpanel Parts sheet Parts appear lower on page |
|
T10004R4 T40004R5 |
T40000R5
series/ discontinued 100 amp/ 8 circuit breaker slots/ GFCI outlets inside box Factory-installed GFCI on some/ inside compartment Two combination décor/toggle switch knockouts on the deadfront. 20-3/4" high x 12-3/4" wide x 4-1/4" deep Buy: T40000R4 enclosure/ no timers/ no GFCI/ T40004RSS/ stainless steel/ T104 timer/ no GFCI T40004R5/ T104 timer/ with GFCI T40404R5/ 2x T104/ with GFCI Resources and manuals 100 amp / Use 1 gauge wire 8 circuit breaker slots/ 1" wide push-down breaker T40000R series manual and sell sheet How to wire Intermatic control center breaker busbar How to wire subpanel How to wire GFCI T40000R4-5 parts sheet Parts appear lower on page |
Control centers
with low voltage transformers for pool lights
100 watt transformer 300 watt transformer |
Low voltage
transformer series Buy replacement transformer: 119T340 300 watt multi-tap transformer 119T267 100 watt replacement transformer |
T10004RT
series/ with T104 timer/ with low
voltage transformer for pool lights/ no breaker slots With one T104 timer Choose: 100 -or- 300 watt low-voltage transformer/ Neutral required Transformer/ 120Volt input (primary)/ 12V-13V-14V 300 watt output (secondary) 100 watt transformer 12V-13V output One knockout on the right side for mounting switching device or GFCI. Two combination décor/toggle switch knockouts on the deadfront. 12.75" x 12.75" wide x 4.24 deep Buy/ no breaker slots: T10004RT1/ T104 timer/ 100 watt transformer T10004RT3/ T104 timer/ 300 watt transformer/ Amazon 119T267 100 watt replacement transformer 119T340 300 watt multi-tap transformer Resources: T10004RT instruction manual Sell sheet Parts sheet Transformer wiring illustration |
|
T10406RT3 T40004RT3 PE30000T3 100 watt and 300 and 600 watt transformer series |
T40000RT
series/ with 240 volt T104 or 120
volt T103/ with low voltage transformer for pool lights / 125 amp/ 8
breaker slots Choose: 240Volt T104 timer -or- 120/240V T103 timer Neutral required Choose: 100 -or- 300 watt low-voltage transformer/ Neutral required Transformer/ 120Volt input (primary)/ 12V-13V-14V 300 watt output (secondary) 100 watt transformers 12V-13V One knockout on the right side for mounting switching device or GFCI. Two combination décor/toggle switch knockouts on the deadfront. 20.75" x 12.75" wide x 4.24 deep Buy/ 8 breaker slots/ 100 amp: 100 amp / Use 1 gauge wire T40000RT3 enclosure/ no timer/ with 300 watt transformer/ 8 breaker slots Amazon PE3000RT / bare panel with 300 watt transformer / 8 breaker slots/ T40003RT3/ 120 v T103 timer/ 300 watt transformer/ 8 breaker slots T40004RT1/ 240 v T104 timer/ 100 watt transformer/ 8 breaker slots T40004RT3/ 240 v T104 timer/ 300 watt transformer/ 8 breaker slots T40604RT3 / 240 v T104 and 240 v T106 timer (for 2 speed pump) / 300 watt transformer / 8 breaker slots Resources: T400000RT instruction manual Sell sheet T400000RT Parts sheet/ pdf Parts sheet PE3000T3 Parts sheet How to wire T103 timer How to wire T104 timer How to wire Intermatic control center breaker busbar for 120-240Volt How to wire subpanel Image of transformer wiring Parts sheet Parts appear lower on page |
1" wide
push-down breaker 1" wide push down breakers Connect wire to breaker. Tighten screw very tight against solid copper wire Hook end of breaker on rail Push breaker down onto busbar Buy: Siemens circuit breakers Breaker bases: 124TP2608A 4 breaker spaces 124T2530A 8 breaker spaces Resource: How to wire Intermatic control center breaker busbar |
|
Circuit
breaker for Intermatic Control panel 1" wide 120Volt, 2" wide 240Volt Push down type breaker Buy Siemens circuit breakers Siemens 208-240 volt 15-125 amp Siemens 120 volt 15-60 amp Square D breaker Schneider breaker |
|
Install wiring devices inside
the enclosure First remove rectangular knock-out(s) in dead front. Remove front panel Remove hex head screws from enclosure and install 21T156A stand-offs in place of screws. 6-32 Attach deco-style wiring device to standoffs. Replace front panel Buy: 21T156A stand-offs pack 4 each 21T166A stand-off 3" long / pack 2 Resource: How to wire control center GFCI |
|
Install GFCI on
side of control panel Neutral is required for GFCI outlet or GFCI combo device Buy: Intermatic WP1100C weatherproof cover Weatherproof receptacle covers Resource: How to wire control center GFCI |
|
Larger image |
Bonding the panel Control panel must be bonded/ refer to local code Bonded means steel panel enclosure must be directly connected to local ground rod Buy: Ground rod and clamps Bonding lugs Resource: How to wire Intermatic control center breaker busbar |
Intermatic 22T713 mounting bracket and PA117 latch Check Intermatic store/ shop.intermatic.com The mounting brackets were previously listed as PA101 ... PA101 is apparently discontinued. |
Larger image Mechanism only Fireman's switch pdf How to wire fireman's switch 156T4042A Fireman switch Amazon |
T100M-
series / Mechanism only/ no box/ add fireman switch to any model/ T101M/ T171M 120Volt SPST 40 amp 2 Hp T171M with day skipper Buy T101M Buy T171M with day skipper How to wire T101M Add fireman switch from Amazon T102M 208-240-277Volt SPST turns off 1 Hot wire / 40 amp 5 Hp Buy T102M How to wire T102M T103M 120Volt clock motor DPST can control 240Volt or other voltage on separate terminals/ 40 amp 2 Hp T173M has day skipper Buy T103M Buy T173M w day-skipper How to wire T103M and T173M T104M 208-240-277Volt DPST/ 40 amp 5 Hp Buy T104M Buy T104M timers How to wire T104M T104M201 208-240Volt DPST with firemans switch (or just buy fireman's switch and add to timer) Buy T104M201 156T4042A Fireman switch Amazon T106M 208-240-277Volt DPDT/ 1NO and 1NC terminals/ 40 amp 5 Hp Buy T106M Buy T106R How to wire T106R |
Timer with enclosure See all T100 series timers How to wire T100 series timers |
|
P1353ME 3-channel
7-day digital timer will snap into Control Center Buy P1353ME timer only PE153ME / timer with metal indoor-outdoor box More Resources P1353ME manual 1.5 Mb/ pdf P1353ME sell sheet/ pdf P1353ME timer and manuals with wiring diagrams Digital control centers and manuals |
Timer
snaps into 22T338GR bracket 6" tall x 5" wide x 2" deep Mount T100 series, ET series to surface or inside larger enclosure Use 22T338GR-bracket inside each Intermatic control center to hold T100 series timers, PE series timers, ET series timers etc Or use independently to surface mount timer inside larger enclosure, or inside competitor's enclosure Buy: 22T338GR Resources: 156T6738A insulators for switch |
Buy trippers 156T1978A set 2 156T1978A trippers PA115 - 25 sets Timer dial can hold 12 sets 1 on- 1 off for each 24 hour period |
Fireman switch turns off pool heater 10 minutes before pool pump turns off. Pool heater must have fireman connection. Do not connect power wires inside timer to fireman switch... the heater connects to fireman switch Can be installed on any T100 series timer. Resources Fireman's switch pdf How to wire fireman's switch Buy: 156T4042A Fireman switch Amazon |
Larger image Insulator/ translucent Buy: 124T1948 single pole T101, T102, T105 124T1948 single pole T171, T172, T175 124T1948 Buy: 124T1952 double-pole T103, T104, T106 124T1952 double-pole T173, T174, T176 124T1952 Resource: How to install insulator Insulator/ pdf |
Insulator/ black rigid 124T2411A rigid pk 25 Buy: 25 pack rigid Resource: How to install insulator Insulator/ pdf |
Look for clock number Consumes 3 watts power |
Clock
motor can be replaced Star screws 3 watt consumption = 26,280 watts per year = 26.28 Kwh per year @ .12 = $3.15 operating cost 60 Hz for US market/ 60 Hz for Europe Asia Resource: How to replace Intermatic clock motor Adapt any timer above to different voltages: Applies to T104, T174, WH40, pool timers etc WG1573 for 60 Hz 208-277V WG1573 208-240Volt WG1570 for 60 Hz 120V WG1570 120Volt WG1576 for 60 Hz 480V WG1576 480Volt CW190-10 for 24 volt 60 Hz 24V at Intermatic America use 60 Hz power. Rest of world uses 50 Hz. 50 and 60 hertz devices are not compatible. Buy 50 HZ for europe etc WG1571 motor for 50 Hz 120Volt at Intermatic WG1574 motor for 50Hz 208-277V Amazon |
Basic
Control
Panels Control panels accept any combinations of T100M, P1353ME, P4243ME or RC2000M or PF1000M Series mechanisms |
Buy
parts: Siemens circuit breakers Trippers T104M 240Volt mechanism T104M201 240Volt T104 240Volt timer T101 120Volt timer 480Volt clock motor 120Volt Clock motor 240Volt Clock motor Fireman switch\ 21T156 Standoffs 156T11047A bonding lug read how to bond control panel Resource: Control center model numbers/pdf Control center parts sheet/ pdf How to bond Intermatic control panel/ pdf Select correct wire size and breaker |
Buy
from my affiliate links every time/ thanks: Amazon ''As an Amazon Associate I earn from qualifying purchases'' Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |