Use only 600 volt wire. Lamp cord, extension cords are not rated 600 volt. Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional. 30 amp breaker use 10 gauge / 120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker. Orange/ #10 gauge wire, with ground ... 30 amp capacity. Safe maximum: 30 x 80% = 24 amps. Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp Southwire electric tools |
Yellow
12 gauge 20 amp 120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire. ... cannot be connected to 30-40 amp breaker. 1 Yellow/ #12 gauge wire, with ground ... 20 amp capacity. Safe maximum 16 amps. Buy: 12-2 gauge/ 20 amp 12-3/ 20 amp NMB is house wiring UF is underground Rolls of stranded wire HOOK UP Wires |
White
14 gauge 15 amp 120 volt 15 amp outlet, AFCI, GFCI, timer, switch etc can be installed on 15 or 20 amp breaker. Never connect 15 gauge wire to 20-30-40 amp breaker. White/ #14 gauge wire, with ground ... 15 amp capacity. Safe maximum 12 amps. Buy: 14-2 gauge/ 15 amp 14-3/ 15 amp NMB is house wiring UF is underground |
50-60
amp breaker use 6 gauge / 240 volt 50 outlet can be installed on 50 amp breaker only Buy: 6-2 wire Southwire electric tools NMB is house wiring UF is underground |
40-50
amp breaker use 8 gauge / 240 volt 40 amp outlet can be installed on 40 or 50 amp breaker only Buy: 8-2 wire Southwire electric tools NMB is house wiring UF is underground |
Copper ground wire. Every device, load, metal enclosure etc must be grounded. Ground wire must be continuous throughout installation, never switched on-off, never used as a Neutral wire. Generally ... use same size as other wire in circuit Buy: 12 gauge copper ground wire Ground wire Green ground wire Ground pigtails Ground rods/ ground clamps at Amazon |
Non metallic flexible cables must carry ground wire, but do not have hazard of short circuit causing injury from shock. Armored steel cable can be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure. All conduit ...metal, plastic ... flexible and rigid ... must be attached to structure, and attached to enclosures, boxes. Movement, damage and deterioration are major cause of electrical failure. Buy: Non-metallic flexible conduit Power whip Armored cable Southwire armored cable cutter Pull boxes |
Electrical tools must be insulated. Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off. Buy: Electrician tools kits KLEIN TOOLS Tools kits IRWIN tools KNIPEX Telephone cable knife Low Voltage Mounting Bracket for Telephone |
Push-on wire connectors in place of twist-on connectorsBuy:Push on wire connectors Amazon Red 3P connector for 10-14 gauge wire Lever connectors for stranded wire at Amazon HOOK UP Wires |
Protect wiring from damage Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. -Code says: Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon |
Electrically insulated tools When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistance and heat on wire and creates possible weak point. Buy tools: KLEIN TOOLS Wire strippers at Amazon Electric Wire Stripping Machine Linesman pliers Utility knife at Amazon |
Multimeters Voltage is tested across two separate wires. Ohms or resistance is tested across both ends of same wire. Amperage is tested along one or two points on same wire. Buy: Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line |
GFCI circuit breaker A GFCI circuit breaker will protect all boxes on circuit. Circuit must be grounded. Ground wire must be continuous and connected to each piece of equipment. White wire on circuit breaker must be connected to Neutral busbar inside the breaker panel. Buy GFCI circuit breakers |
Push down 1" wide Push down breaker Plug-in breaker Buy single-pole: Choose from 15 to 60 amp Eaton CL series Siemens 15-60 amp Single-pole tandem breaker Tandem breakers |
Push down 2" wide Push down breaker Plug-in breakers Buy double-pole: Choose from 15 to 125 amp Choose from 15 amp to 200 amp Eaton CL series circuit breaker Siemens circuit breaker Double pole GFCI |
ON
Delay with programmable timer Illustration shows ON delay wiring. On delay means the load turns ON after delay period expires. Load remains ON until power is off. Example uses ST01 timer as switch. (Or use Ei600... same timer with 5-year warranty) ST01 Timer can be set for dusk-dawn. Automatically turns lights ON at night, and off at dusk. ST01 Timer automatically adjusts for seasonal changes. ST01 Timer can be adjusted 20 minutes longer or shorter than actual dusk-dawn However some folks want longer delay before lights turn ON at night How it works: ST01 Timer turns ON. AH3 timer receives power. Time delay countdown begins. After delay period expires, light turns ON, and remains ON until ST01 timer turns OFF Cycle repeats next time the ST01 timer turns ON. Buy: AH3 timers at Amazon Intermatic ST01 timer Ei600 timer at Amazon CR2 replacement battery at Amazon Resources: More wiring diagrams/ How to wire AH3 |
For 120-240V cut blue jumper wire located on front of timer between terminals Adjustments less than 30 seconds might not be possible 2" x 2" size |
1.8
second delay Start motor or pump with 1.8 second to 10 minute delay Time delay begins when power is applied to input. After delay, load turns ON and stays ON until power is turned OFF. Buy 120-240 Volt delay ON: ICM 102 / 18-240VAC 1.5 amp load ICM controls Packard 102 at Amazon Buy: contactors: Packard contactor with 24Volt coil 120Volt coil At Amazon 240Volt coil At Amazon Resource: ICM 102 delay ON timer manual .pdf More contactors Terminals Fuseholders Enclosures |
For 120-240V cut
blue jumper wire located on front of timer between terminals
Adjustments less than 30 seconds might not be possible |
Delay Turn on 1 motor after another motor starts Turn on pump after another pump starts Turn on 1 motor before another motor 120Volt or 240Volt In-line fuse protects on-delay timer Load 1 Turns ON when switch or timer turns ON. Load 2 turns ON after delay Reason for this system might be to reduct initial load on circuit so motor do not pull starting amps at same time. Another reason is that one pump feeds water to second pump. Second pump should not start until water arrives from first pump. |
Elko delay timer/
Multifunction On-delay, off-delay, repeat cycle, delay on break, pulse generator, latching, single shot Input voltage 12V - 240 volt (50-60 Hz) Indicator lights for power and countdown .1 seconds to 10 days Terminal S is trigger switch for some functions, install additional switch on a wire that connects to both terminal A1 and S... when the S wire is switched on, it causes the function to begin, such as latching relay or single shot, neither function useful for the illustration shown on left, or required for ordinary on or off delay. Caution, fuse required on hot line(s) as illustrated. Buy: Elko delay timer Migro delay timer Migro relays and timers Resources: CRM-93H 10-function CRM-91H 10 function CRM-82 two-function Enclosures |
120Volt meter for any plug-in device Resources: Instruction .pdf Buy: Energy meters at Amazon |
|
240 volt Meter on any circuit Use Kwh hour meter to record power usage of motor, or any electrical device. This is most accurate way to determine what percentage of bill is going to any particular device. To connect meter: Temporarily disconnect wires from top of heater. Install meter on two jumper wires. Use jumpers to temporarily reconnect power to water heater. Cover with tape to secure temporary connection. Add conduit and junction box if meter is to be installed for any length of time. Buy 240 volt pass through Kwh meter |
|
Estimate
cost of operation Hard wire 120V or 240V or 12 VDC. Connect to wires going to load. Meter will run whenever power is available. Hour meter counts hours that load is receiving power Reliable Intermatic industrial quality 100 hours 240 volt 1 Hp 1 Hp uses 8 amps @ 240V 100 hours x 240 volts x 8 amps = 192 Kwh Buy from my affiliate links: UWZ48E-240V AC hour meter at Amazon Intermatic bezel to support UWZ hour meter Intermatic ac hour meters at Amazon 240 volt hour meter Intermatic GZ series 10-80 VDC hour meter Intermatic FWZ53-24U 12 volt DC hour meters Resource: UWZ series hour meter .pdf |
|
Estimate
cost of operation/ wireless No wiring needed. Hour meter works on vibration Reliable Intermatic industrial quality For example, meter records 100 hours on a 240 volt 1 Hp motor or pump 1 Hp uses 8 amps @ 240V 100 hours x 240 volts x 8 amps = 192 Kwh (kilowatthours) Pumps use brief surge of amps during start up, so add 10% more for better exstimate. Works for cars too Buy from my affiliate links: Vibration hour meter at Amazon Flush mount hour meter works on vibration Resource: Vibration meter .pdf |
Use
in-line fuse when connecting 2 different gauge wires Illustration shows smaller 12-2 cable connected to larger 10-3 cable. The 10 gauge wire carries 240 volt plus a Neutral wire, and is protected by 30 amp breaker The amp draw on 30 amp breaker is too large for 12 gauge wire. 12 gauge wire should have 20 amp breaker. Connect
smaller
12 gauge wire to 10 gauge wire using twist on wire connector. All
connections must be inside electrically rated enclosed box with cover.
Use fuseholder with 20 amp fuse.Fuse will protect entire length of 12 gauge wire. Connect fuse to Hot wire. Never put fuse on Neutral ... the Neutral wire must never be switched off, and must run continuous throughout installation. If the 12 gauge wire is wired for 240V, instead of 120V shown in illustration, then fuses can be added to both hot wires. Always make connections inside a box with cover Buy: Panel mount fuse holders at Amazon ANL fuseholder Buy fuseholders Din rail fuseholder 10 x 38 mm fuse Electrical terminals Solder guns Resource: Fuseholders |
|
Larger image |
How
to wire WeMo switch WeMo allows programming via smart phone Do not use stranded wire under screw plates Buy from my affiliate links: WeMo switch Contactor with 120 volt coil 6x6x4 Box to install contactor Resources: WeMo switch and module wiring Illustrations of contactor wiring Select correct wire and breaker size Contactors |
Control
pump with cell phone using WeMo WeMo plugs into ordinary 120volt outlet Control WeMo using phone or tablet Grundfos pump is 1/25 Hp, and will work fine without overloading wemo. Buy from my associate links WeMo at Amazon Belkin WeMo at Amazon Unlocked smartphone Resources: How to install recirculation system Vibration meter .pdf |
|
Skylink wireless countdown |
Operate
120 volt remotely/ program or countdown Skylink wireless programmable or countdown Estimate 1/3 Hp Grundfos pump is 1/25 Hp 120V 60 Hz/ 10 watt minimum/ 1500 watt Operate as ON-OFF or Countdown device/ Up to 500 feet 15 minute - 60 minute countdown Buy: Wireless wall mount transmitter TB-318 at Amazon Wireless countdown receiver PA-318 at Amazon Transmitter and receiver Resource: PA-318 manual |
ST01C timer controls 120Volt delay-off-timer Activate off-delay timer using push button -or- using ST10 timer Push button, or ST01, activates delay timer. Push button gives momentary on-off to activate delay timer When ST01 turns ON and then OFF, then delay timer activates Delay timer turns Load ON Delay timer begins countdown. When countdown expires, delay timer turns Load Off Buy from my affiliate links: 6A855 Solid State timer at Amazon 11-pin plug-in base at Amazon Contactor with 120volt coil ST01 battery-operated timer Resource: 6A855 Manual More off-delay timers |
|
Operate
recirculation system remotely from
1-2-3+ different locations How it works: Do NOT connect voltage to bell wire going to push buttons Buy delay timer and base Connect 120volt Hot and Neutral wires to base as illustrated. Buy thermostat or bell wire and connect to push buttons as shown The push buttons receive no voltage or power... do not connect to power source. Plug timer into base. Choose delay time from .05 seconds to 999 seconds Push doorbell button. Activates timer. Timer turns ON and begins countdown. Pump turns ON and runs until countdown stops. Countdown is off-delay. When countdown expires, timer turns OFF, pump turns OFF. Delay timer rated 1/3 Hp.... recirculation pump rated 1/25 Hp Buy project materials: Example 50' thermostat bell wire at Amazon 6A855 Solid State timer at Amazon 11-pin plug-in base at Amazon Push button plate Amazon Resources Other countdown timers More off delay and pin timer illustrations 6A855 Manual |
|
Larger image Remote control countdown timer Buy: 6A855 Solid State timer at Amazon 11-pin plug-in base at Amazon General purpose relay Woods 32555 at Amazon GE at Amazon Wireless remote controls at Amazon Replacement A23 battery at Amazon Select recirculation pump Resources: See analog plug-in timers See remote controls Water heater recirculation system How to wire off delay timer |
Larger image Larger image 2 |
Control motor with 2 switches Same wiring diagram applies to single-pole switch Contactor with 240Volt coil Buy: 240Volt coil At Amazon Start winding pulls more amps than switch can safely handle. Over time, the switch will fail. Contactors are rated for heavy amp loads, with expected life of millions of operations |
Use contactor or
miniature relay Resource: Zetter-relay-wiring.jpg Buy: contactors: Packard contactor with 24Volt coil 120Volt coil At Amazon 240Volt coil At Amazon |
6x6x4 Box with cover Metal box comes with knock-outs Plastic box/ drill 3/4" for 1/2' knock out Buy 6x6x4 metal enclosure 6x6x4 PVC plastic enclosure Step drill bit for drilling into PVC box |
Contactors 2-Pole 40A resistive Rated 1 million operations Inrush 27 watts, 7 watt operation Buy 120Volt coil At Amazon 240Volt coil At Amazon Other contactors Mars 2-pole and 3-pole 3-pole contactors Resources: Read more about contactors |
Decora wall-plates Buy from my associate links Decora wall-plates Decora wall-plates Decora wall-plates |
6X6X4 Metal box w/ Contactor 6x6x4 Plastic box |
Buy
6x6x4 junction box Plastic box and metal boxes Available home center/ electric supply house/ or online Buy: 6x6x4 plastic box: no pre-drilled holes... must drill holes for Wire connections, 1/2" hole for fuseholder, 3/16" holes for bolts to hold contactor, plastic box does not need ground screw connected to box Cantex 6x6x4 PVC plastic enclosure with cover at Amazon Thomas and Betts 6x6x4 plastic with cover at Amazon Bud industries 11x7x5 box without knockouts Buy: 6x6x4 Metal box: has knock-outs for 1/2 and 3/4" ... must drill 1/2" hole for fuseholder, bolt holes to hold contactor, threaded holes for 10-32 ground screw, metal box must be grounded. Raco 6x6x4 metal pull box with cover and knock-outs Raco 6x6x4 metal pull box with cover and knock-outs RACO outdoor 6x6x4 box with bottom knockouts Wiegmann 67x6x4 pull box with knockouts on 4 sides Hoffman 6x6xx4 pull box with knockouts on 4 sides Buy 6x8x4 metal box Bud industries 6x8x4 box with hinged door Bud industries boxes at Amazon Resource: See more about boxes |
Buy
inline fuseholder and ceramic fuse to protect timer from overload Buy: Panel mount fuse holders at Amazon ANL fuseholder Buy fuseholders at Amazon Ceramic fuses at Amazon Din rail fuseholder 10 x 38 mm fuse Resource: Read about fuseholders |
Use only 600 volt wire. Lamp cord, extension cords are not rated 600 volt. Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional. 30 amp breaker use 10 gauge / 120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker. Orange/ #10 gauge wire, with ground ... 30 amp capacity. Safe maximum: 30 x 80% = 24 amps. Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp Southwire electric tools |
Yellow
12 gauge 20 amp 120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire. ... cannot be connected to 30-40 amp breaker. Yellow/ #12 gauge wire, with ground ... 20 amp capacity. Safe maximum 16 amps. Buy: 12-2 gauge/ 20 amp 12-3/ 20 amp NMB is house wiring UF is underground Rolls of stranded wire |
White
14 gauge 15 amp 120 volt 15 amp outlet, AFCI, GFCI, timer, switch etc can be installed on 15 or 20 amp breaker. Never connect 15 gauge wire to 20-30-40 amp breaker. White/ #14 gauge wire, with ground ... 15 amp capacity. Safe maximum 12 amps. Buy: 14-2 gauge/ 15 amp 14-3/ 15 amp NMB is house wiring UF is underground |
50-60
amp breaker use 6 gauge / 240 volt 50 outlet can be installed on 50 amp breaker only Buy: 6-2 wire Southwire electric tools NMB is house wiring UF is underground |
40-50
amp breaker use 8 gauge / 240 volt 40 amp outlet can be installed on 40 or 50 amp breaker only Buy: 8-2 wire Southwire electric tools NMB is house wiring UF is underground |
Copper ground wire. Every device, load, metal enclosure etc must be grounded. Ground wire must be continuous throughout installation, never switched on-off, never used as a Neutral wire. Generally ... use same size as other wire in circuit Buy: 12 gauge copper ground wire Ground wire Green ground wire Ground pigtails Ground rods/ ground clamps at Amazon |
Armored cable can be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure. Non metallic flexible cables must carry ground wire, but does not have hazard of short circuit causing injury from shock. All conduit ...metal, plastic ... flexible and rigid ... must be attached to structure, and attached to enclosures, boxes. Movement, damage and deterioration are major cause of electrical failure. Buy: Armored cable Southwire armored cable cutter Non-metallic flexible conduit Power whip Pull boxes |
Electrical tools must be insulated. Always best to disconnect power, but issues of insulation failure, lack of proper grounding, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems pose a risk to anyone working on electric power. Buy: Electrician tools kits Klein tools Tools kits |
12 ga Stranded wire is good for conduit with multiple wires ... but stranded cannot be installed under screw terminals on outlets, switches, timers etc without risk ... of heat causing splayed strands ....that come loose ... and begin to arc. Connect stranded to short piece of solid copper wire, and attach solid to screw terminal. Do not solder residential or commercial wiring. Buy: Rolls of stranded wire |
Protect wiring from damage Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. -Code says: Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon |
Electrically insulated tools When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistances and heat on wire and creates possible weak point. Buy tools: Wire strippers at Amazon Linesman pliers Utility knife at Amazon |
Multimeters Voltage is tested across two separate wires. Ohms or resistance is tested across both ends of same wire. Amperage is tested along one or two points on same wire. Buy: Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line |
Contactors/ relays |
|
|
Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |