240 Volt with WeMo How to wire wifi Resource:: Safe electric wiring |
Use only 600 volt wire. Lamp cord, extension cords are not rated 600 volt. Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional. 30 amp breaker use 10 gauge / 120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker. Orange/ #10 gauge wire, with ground ... 30 amp capacity. Safe maximum: 30 x 80% = 24 amps. Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp Southwire electric tools |
Yellow
12 gauge 20 amp 120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire. ... cannot be connected to 30-40 amp breaker. 1 Yellow/ #12 gauge wire, with ground ... 20 amp capacity. Safe maximum 16 amps. Buy: 12-2 gauge/ 20 amp 12-3/ 20 amp NMB is house wiring UF is underground Rolls of stranded wire HOOK UP Wires |
White
14 gauge 15 amp 120 volt 15 amp outlet, AFCI, GFCI, timer, switch etc can be installed on 15 or 20 amp breaker. Never connect 15 gauge wire to 20-30-40 amp breaker. White/ #14 gauge wire, with ground ... 15 amp capacity. Safe maximum 12 amps. Buy: 14-2 gauge/ 15 amp 14-3/ 15 amp NMB is house wiring UF is underground |
50-60
amp breaker use 6 gauge / 240 volt 50 outlet can be installed on 50 amp breaker only Buy: 6-2 wire Southwire electric tools NMB is house wiring UF is underground |
40-50
amp breaker use 8 gauge / 240 volt 40 amp outlet can be installed on 40 or 50 amp breaker only Buy: 8-2 wire Southwire electric tools NMB is house wiring UF is underground |
Copper ground wire. Every device, load, metal enclosure etc must be grounded. Ground wire must be continuous throughout installation, never switched on-off, never used as a Neutral wire. Generally ... use same size as other wire in circuit Buy: 12 gauge copper ground wire Ground wire Green ground wire Ground pigtails Ground rods/ ground clamps at Amazon |
Non metallic flexible cables must carry ground wire, but do not have hazard of short circuit causing injury from shock. Armored steel cable can be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure. All conduit ...metal, plastic ... flexible and rigid ... must be attached to structure, and attached to enclosures, boxes. Movement, damage and deterioration are major cause of electrical failure. Buy: Non-metallic flexible conduit Power whip Armored cable Southwire armored cable cutter Pull boxes |
Electrical tools must be insulated. Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off. Buy: Electrician tools kits KLEIN TOOLS Tools kits IRWIN tools KNIPEX Telephone cable knife Low Voltage Mounting Bracket for Telephone |
Push-on wire connectors in place of twist-on connectorsBuy:Push on wire connectors Amazon Red 3P connector for 10-14 gauge wire Lever connectors for stranded wire at Amazon HOOK UP Wires |
Protect wiring from damage Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. -Code says: Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon |
Electrically insulated tools When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistance and heat on wire and creates possible weak point. Buy tools: KLEIN TOOLS Wire strippers at Amazon Electric Wire Stripping Machine Linesman pliers Utility knife at Amazon |
Multimeters Voltage is tested across two separate wires. Ohms or resistance is tested across both ends of same wire. Amperage is tested along one or two points on same wire. Buy: Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line |
GFCI circuit breaker A GFCI circuit breaker will protect all boxes on circuit. Circuit must be grounded. Ground wire must be continuous and connected to each piece of equipment. White wire on circuit breaker must be connected to Neutral busbar inside the breaker panel. Buy GFCI circuit breakers |
Push down 1" wide Push down breaker Plug-in breaker Buy single-pole: Choose from 15 to 60 amp Eaton CL series Siemens 15-60 amp Single-pole tandem breaker Tandem breakers |
Push down 2" wide Push down breaker Plug-in breakers Buy double-pole: Choose from 15 to 125 amp Choose from 15 amp to 200 amp Eaton CL series circuit breaker Siemens circuit breaker Double pole GFCI |
Larger image |
Control
gas water heater with WeMo
Control gas water heater with Phone WeMo programming resources are online No subscription WeMo plugs into ordinary 120volt outlet Control WeMo using phone or tablet Buy: WeMo at Amazon Belkin WeMo at Amazon Gas water heater timer coupon Resource: Gas water heater timer How to set up wemo on your wifi network |
Control
water heater with WeMo WeMo programming resources are online No subscription WeMo plugs into ordinary 120volt outlet Control WeMo using phone or tablet Buy from my associate links WeMo at Amazon Belkin WeMo at Amazon Contactor with 120 volt coil Terminal kit Blue for 16-14 wire Yellow for 12-10 wire Unlocked cell phone at Amazon Unlocked smartphone Resources: Contactors How to wire the contactor Terminals Select wire and breaker size Setting up WeMo |
|
Use ordinary household remote
control
to
control 120 or 240 volt motor Buy from my associate links Woods 32555 at Amazon GE at Amazon Wireless remote controls at Amazon Skylink remote controls Contactor with 120 volt coil Resources: How to wire the contactor |
|
Larger image |
Use WeMo or WiFi or Zwave module to control 120 or 240 volt motor or water heater Buy from my associate links WeMo at Amazon Belkin WeMo at Amazon Woods wifi WiOn Zwave module Contactor with 120 volt coil Unlocked cell phone at Amazon Unlocked smartphone Resources: How to wire the contactor |
Larger image |
Control 240
volt load with WeMo WeMo programming resources are online No subscription Control WeMo using phone or tablet Illustration shows Chassis-mount transformer that converts 240 volt to 120 volt to power WeMo switch Test this concept: make sure magnetic field does not interfere with WeMo operation. Buy: Transformer/ 25 watt output/ 2.8" diameter x 1.25 thick Transformer option 2 Contactor with 120 volt coil 7 watt power consumption WeMo wi-fi light switch/ unknown watt consumption/ works with cell phone app Panel mount fuse holders at Amazon Cantex 6x6x4 plastic junction box metal enclosure |
Larger image |
Neutral required for timers, wifi, zwave: This plan draws hot and neutral from a small transformer Buy: Transformer/ 25 watt output/ 2.8" diameter x 1.25 thick Transformer option 2 Contactor with 120 volt coil 7 watt power consumption Programmable timer Countdown timer Zwave switch Wifi switch |
Larger image |
Override switch for timers, wifi, zwave: This plan draws hot and neutral from a small transformer Use regular 15 amp 3-way wall switch from hardware. Transformer rated 23 watts. Contactor consumes 27 watt for brief moment during inrush (start-up) and 7 watts during operation. Can't find power consumption for wifi switch... can't be zero ... seems the information highway is stalled by commerce. Transformers are very reliable with no moving parts, however the WeMo, wifi, zwave and digital timers are not as reliable, and override might be needed both for convenience and testing. To bypass the contactor the altogether requires 30 amp DPDT switch Buy: 3-way switch Transformer/ 25 watt output/ 2.8" diameter x 1.25 thick Transformer option 2 Contactor with 120 volt coil 7 watt power consumption Programmable timer Countdown timer Zwave switch Wifi switch |
Larger image
What is a contactor? What is a contactor? Contactor is a switch. It is rated for high amp loads. High amp causes heat. Heat will damage regular electrical parts. Timers and wall switches can be damaged by high amperage. Each switch and timer has amp rating. Contactors are rated for more amps than ordinary wall switch or timer. The electrical circuit lasts longer when a contactor is used because contact points on a contactor are designed to switch high amp loads without melting or being damaged by heat. The electromagnetic coil can be switched on-off using ordinary wall switch or timer. When voltage is applied to coil, then contact points close, and heavy amp circuit turns on. This lets you control heavy amp loads using ordinary wall switch or timer. Buy: Mars 2-pole and 3-pole contactors Terminal kit Blue for 16-14 wire Yellow for 12-10 wire Resource: Contactors and relays 3-pole/ 3 phase contactors Enclosures and boxes |
|
Use correct size large screwdriver or #3 square head
driver. Use T handle driver instead of cordelss tool for best torque without damage Cordless driver can sometimes crack apart circuit breaker, outlet, switch etc, and might slip from screw before wires are firmly attached. Buy: Square drive set T handle nut driver Ratchet screwdriver Resources: Safe electric wiring Color code wire Extension cord code |
|
Larger image |
Contactor water heater
with 120 Volt
coil Buy: Packard contactor at Amazon/ 40 amp/ rated 7 million operations 7 watt operation/ 27 watt inrush Resources: Contactors Terminals Select wire and breaker sizes |
Larger image |
Buy: Bud Industries 6x6x4 with metal cover Handy utility box Square box extension ring Box cover Box cover Raco box cover |
Larger image |
How
to wire WeMo switch/ hardwire Do not use stranded wire under screw plates Buy: WeMo switch Contactor with 120 volt coil 6x6x4 Box to install contactor Resources: Illustrations of contactor wiring Select correct wire and breaker size Contactors |
Larger image |
How
to wire WeMo switch/ same as above
except using extension cord instead
of hardwire 120 volt outlet has Hot and Neutral wires as illustrated. 3-prong extension cord also has Hot and Neutral Make sure WeMo white wire connects to Neutral Use either black wire on WeMo Make sure contactor has 120 volt coil Do not use stranded wire under screw plates Buy: WeMo switch Contactor with 120 volt coil 6x6x4 Box to install contactor Bud boxes at Amazon Resources How to install terminals Illustrations of contactor wiring |
Ground wire should be connected to ground wire on water heater wire Larger image |
WeMo
controller kit in plastic box Comes with WeMo and contactor plus 240V-to-120V transformer Assembly required. Install ground wire as shown. Water heater cable does not have Neutral. WeMo requires Neutral. If you connect Neutral to ground, it will work. But in event of nearby lightning strike, or other ground disturbance, the surge of power is directed down the ground wire, and MIGHT enter the WeMo and cause fire. Ground wires offer path of least resistance for surge events because all grounds are wired directly together without passing through devices like switch etc. Installing VPT230 will reduce magnetic field interference with WeMo RECOMMEND pvc or plastic box so wi-fi signal is not blocked Buy: Transformer Transformer option 2 Cantex 6x6x4 plastic box WeMo switch Contactor with 120 volt coil Panel mount fuse holders at Amazon Buy: Step drill bit for drilling into PVC box Resource: Set up manual for transformer VPT230 transformer manual WeMo controller kit manual |
Larger image This wiring is not code. Use wiring diagram shown above |
|
Override WeMo switch
By-pass WeMo switch To override, you want to connect both black wires on the WeMo. Ordinary 15A wall switch will do... or spring-wound countdown timer... or different type of zwave control../. or remote push button with delay-off... Resources: Spring-wound Countdown timers Remote control delay timer |
|
Control
pump with cell phone using WeMo If WeMo or Iris offers a delay option WeMo programming resources are online No subscription WeMo plugs into ordinary 120volt outlet Control WeMo using phone or tablet Buy from my associate links WeMo at Amazon Belkin WeMo at Amazon Unlocked smartphone Resource: How to install recirculation system |
|
Operate
120 volt recirculation system remotely Skylink wireless countdown Skylink estimate 1/3 Hp Grundfos pump is 1/25 Hp 120V 60 Hz/ 10 watt minimum/ 1500 watt Operate as ON-OFF or Countdown device/ Up to 500 feet 15 minute - 60 minute countdown Buy: Wireless wall mount transmitter TB-318 at Amazon Wireless countdown receiver PA-318 at Amazon Transmitter and receiver Resource: PA-318 manual How to install recirculation system |
|
Zwave How to control water heater with zwave switch How to control water heater with zwave contactor Wifi How to control water heater with wifi contactor |
Larger image 9-3 ⁄8" x 5-1 ⁄2" x 3-5 ⁄8" Enclosures can be used for timers or for other electrical for electrical control center... Shown are several devices mounted to din rail. The din rail must be firmly attached to enclosure. Delay timers will fit if mounted directly to metal box, and not din rail. Note that the
LY2-LY3 15 amp relays are rated 10 amps for 2 and 3-pole relays. And 5
amps for LY4 4-pole relay.
Buy:2T511GA Nema3R enclosure at Amazon 10 amp Relays 10 amp LY2 relays LY3 relay 120 volt LY2 15 amp Din rail timer Din rail Fuseholder Resources: Din rail timers Off Delay timers On delay timers Build 3-phase astronomic timer Build 2-speed timer for pump, motor etc |
Larger image Another image Contactor, open-frame relay, and small relay with base will fit into Intermatic metal and plastic enclosures, but not the smaller Grasslin enclosures. Note that a 30 amp
power relay, or switch, or contactor has safe maximum
80% rated value, or 24 amps. For 30 amp circuit, must use 600 volt, 10
gauge solid copper wire. Never undersize wire or use extension cord for
permanent wiring.
Buy: 2T511GA Nema3R enclosure at Amazon Siemens 30 amp power relay 30-40 amp Contactors Resources: Contactors and relays How to wire open frame relay Build a 2-speed motor control |
Buy from my associate links: WeMo switch WeMo at Amazon Belkin WeMo at Amazon Unlocked smartphone |
Buy from my associate links: 12-2 gauge/ 20 amp 12-3/ 20 amp Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp NMB is house wiring UF is underground Resource: Match wire and breaker size |
6x6x4 Box with cover Metal box comes with knock-outs Plastic box/ drill 3/4" for 1/2' knock out Buy from my associate links 6x6x4 metal enclosure 6x6x4 PVC plastic enclosure\ Step drill bit for drilling into PVC box |
Contactors 2-Pole 40A resistive Rated 1 million operations Inrush 27 watts, 7 watt operation Buy from my associate links 120Volt coil At Amazon 240Volt coil At Amazon Other contactors Mars 2-pole and 3-pole 3-pole contactors Resources: Read more about contactors |
Multimeter Test for breaks in wire/ Test for voltage Most appliance require 80% rated voltage to function correctly Buy Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line Resource: How to test and replace element How to test thermocouple Element tests for 120 volts How to test wire |
Safety
when testing wires:
Never touch wet or previously flooded appliance. Never stand on wet surface when working on electric. Never stand on bare soil, put down dry boards. Tape tester leads to wood sticks to keep hands away from power. Use non-contact voltage tester before touching wires. Never touch or lean into any made of metal. Remove metal objects from pockets. Do not use oxygen or fuel accelerants in same room as electrical repairs Resource: Basic house wiring |
Non-contact voltage tester Test for power without touching connectors NEVER assume power is OFF Buy: Non-contact voltage tester Amazon Electric testers at Amazon Resource: How to test electric power is off |
120 volt 15 amp devices
including GFCI, timers, switches, plugs, wifi controls etc can be
installed on 15 or 20
amp
breaker. 120 volt GFCI, outlet, receptacle that is rated 20 amp can be installed on 20 amp breaker only, but NOT on 15 amp breaker. Buy 15 amp GFCI 20 amp GFCI |
Buy Basic electric book Home plumbing/ electrical codes Or learn about basic household electricity... use and search my site/ Resource Safe electric wiring Basic house wiring |
Use outlet tester to check for correct wiring on any 120 volt straight-blade outlet. Buy: Klein testers Outlet tester Circuit breaker finder Electric usage monitor |
Twist-on wire connector assortmentsDo not reuse old connectorsTwist wire connector very tight. Pull wires to ensure they will not come loose. Cover all bare copper. Buy: Connector assortment at Amazon Connector assortment at Amazon Resource How to select and install twist-on wire connectors |
Weatherproof wire connectorConnector cavity is full of siliconeBuilt-in cover keeps silicone in place Protect from water, dust etc Buy from my affiliate links Weatherproof size 14 to 6 Amazon Weatherproof size 22 to 8 Amazon Resource How to select and install connectors |
Connect wire to screw terminal Use only 600 volt solid copper wire. Do not use stranded wire or extension cord. Do not use solder anywhere on residential 120-240 volt wiring. Attach electric installation to structure. Tighten screws very tight against wire. Buy: NEC books Dewalt plumbing/ electrical codes Basic electric book National electric code guide/ illustrated Resources: How to twist wire How to select and install twist-on wire connectors |
Weatherproof
lever switch on outdoor lights Safely operate outdoor toggle switch Replaces outdoor cover Install over top of ordinary switch Works with single-pole, double-pole, 3PST, 3-way, 4-way switches etc Use weatherproof box for outdoor Can be used indoor or outdoor Buy: Best choice: Cantex lever switch Outdoor lever switches at Amazon Lever switches Resource Cantex-toggle-switch-covers.pdf Cantex-PVC-junction-boxes.pdf |
TerminalsBuy:Terminal kit Blue for 16-14 wire Yellow for 12-10 wire Resource: How to install terminal |
Push-on wire connectors in place of twist-on connectorsBuy:Push on wire connectors Amazon Red 3P connector for 10-14 gauge wire Lever connectors for stranded wire at Amazon |
Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. Code -Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon |
When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistances on wire and creates weak point. Buy tools: Wire strippers at Amazon Linesman pliers Pro linesman plier Needle nose pliers End cutting nippers at Amazon |
Weather resistant plastic box for outdoor extension cord connections, Christmas lights, outdoor power strip etc . Not for connecting wires with wire nutsŪ, or in-wall wiring, but can be used indoors to organize extension cords, power strips etc. Weather resistant is not weatherproof or watertight. Use enclosures rated IP65 and IP67 for waterproof. Extension cords cannot be used for permanent wiring. Buy: Large-medium-small electric cord box Socketbox Raintight enclosures Water-tight cord lock Resource: Enclosures and boxes |
Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |