How electric water heater works |
![]() Elements are controlled by upper and lower thermostats. Each element is connected to a thermostat. Thermostats read temperature through side of tank wall and turn elements ON and OFF. Residential water heater thermostats can be manually set to temperatures between 90º to 150º or 110° to 160° depending on brand. Higher thermostat settings use more electricity. Commercial water heater thermostats 120-180º. Do not install commercial thermostats on residential water heater. Resources How to adjust thermostats How to replace thermostat on electric water heater How to wire thermostats Both elements on ordinary residential water heater are never ON at same time unless specific wiring is changed. Upper thermostat is main controller. Starting with a cold tank, upper thermostat turns on upper element until top 2/3 of tank reaches temperature setting. After top of tank is heated, upper thermostat turns-off upper element and sends power to lower thermostat which turns on lower element. Lower element runs until tank reaches temperature setting. Lower element turns on-and-off during standby hours to keep tank temperature at thermostat set point. There is no air inside tank. When hot tap is turned on at kitchen sink, hot water immediately exits top of tank. Hot water travels through hot-side pipe until it reaches faucet. At same moment hot leaves top of tank, new cold water immediately enters bottom of tank through plastic dip tube pipe. To save energy, never turn on hot tap when using only cold... because new cold water that enters tank must be heated to set point. Resources Read about dip tube 9-ways to save with water heater During 'standby' hours, between hot water use, lower element maintains tank temperature. Lower element keeps water hot by turning-on approximately 1-4 minutes each hour throughout day and night which equals 45Kwh - 216Kwh each month for standby operation depending on tank efficiency, maintenance, and seasonal incoming cold water temperature. Newer tanks with more insulation, or tanks located in naturally warm area turn on less frequently. Resources See math charts for heating water Kwh hour calculations Once hot water is used at faucet, cold water quickly fills bottom of tank. Lower element is a ctivated first, and when the upper part of tank is below set point, the lower element truns off and upper element turns on, and the heat cycle repeats. The temperature of incoming cold water affects how much energy is consumed. In winter, the incoming water is colder. Colder water means the elements must heat longer to reach the thermostat set point. Average groundwater temperature Tempering tank |
![]() Larger image Typical operation sequence of residential non-simultaneous water heater |
![]() |
The energy smart water heater operates same
as
residential non-simultaneous 2-element tank described above. The difference is energy smart uses electronic sensors to measure temperature and activate elements. Resources Whirlpool Energy smart electric Convert energy smart to regular water heater |
![]() |
Commercial
electric water heaters 3-phase electric is different than single-phase residential electricity. 3-phase non-balanced commercial water heaters are very similar to residential heaters and can be converted to residential use with a few alterations.' 3-phase balanced water heaters ahave similarities to residential heaters, but can vary depending on model of heater. Resources What is 3-phase 3-phase water heater Difference between single phase and 3-phase |
![]() |
Wiring Residential water is connected to 240 volt dedicated double breaker that serves no other load. ![]() Resources: Basic 240Volt water heater circuit How to wire thermostats Water heater is tripping circuit breaker Figure volts, amps, watts Wire and breaker size chart |
![]() |
Wiring Illustration shows basic wiring for 2-element non-simultaneous residential water heater. Wire colors vary. Resources: How to wire thermostats How to replace wire on water heater Water heater voltage: Electric water heaters work on any voltage 120, 208, 230, 240, 277 etc: Resources: How to connect water heater to generator Convert water heater to 120Volt 3-phase water heater Figure volts amps watts |
![]() -WET water heater is dangerous. Do not touch leaking water heater or water heater that is wet or was flooded without turning power off. - Gas and electric water heaters are both connected to water pipes and can act as ground conduit for electricity. Turn power OFF. Always turn power OFF when working on electric water heater ![]() NEVER assume power is OFF Buy: Non-contact voltage tester Amazon Electric testers at Amazon Resources: Water heater safety precautions How to test electric power is off |
![]() |
Elements![]() Check label on side of tank for for voltage and wattage <> tank wattage is element wattage In 2-element tank, if lower element burns out, the amount of hot water is reduced. On 2-element tank, if upper element burns out, the lower element stops receiving electric power so neither element works and no hot water is available. Resources: Figure Volts Amps Watts for water heater How to identify and replace water heater elements How change element and remove sediment How to troubleshoot electric water heater Convert water heater to 120Volt for slower heating |
![]() |
Elements![]() Water heater elements are resistive, and similar to electric stove burners, except designed to be immersed in water. Elements instantly burn out if no water is inside tank. Elements burn out for different reasons and can be replaced. Resources: How to test elements. How to replace elements. Resources: How to troubleshoot electric water heater |
![]() Steel water heater tanks have anode rod that prevents tank from rusting. Periodic inspection and replacement of anode rod will extend life of water heater Save money by turning down thermostats For each 10º reduction, save 3-5% Resources: See how to turn down thermostat. How to increase amount of hot water Resources: How to adjust thermostats How to replace thermostat on electric water heater How to wire thermostats Troubleshoot water heater Basic water heater circuit Add another thermostat to gas or electric heater |
|
![]() Tanks with two-elements are rated 240Volt Larger image |
![]() Cover, insulation and protector are necessary so thermostat can read correct temperature Reset button on upper thermostat of electric water heater is a safety feature and will trip when water inside tank reaches dangerous 170°F Remove upper cover and insulation to access reset button. Firmly push in reset button. If reset wilol not engage, then let tank cool before trying again. If problem persists, replace thermostat. Resource How to troubleshoot electric water heater |
![]() Larger image |
Install: Electric heater can be installed inside any unventilated space, for example a closet with door closed Electric water heaters do not burn hydrocarbon fuel and require no incoming oxygen supply or vent to outside. Water heater is steel tank, covered with insulation, and surrounded by metal shell 1) Steel tank holds pressure of hot water. 2) Tank can be rusted and leaking. 3) Insulation helps prevent heat loss. Install in naturally warm area helps efficiency. 4) Metal tank shell protects wires from damage. 5) Any short to metal tank will trip breaker. Ground wire must be connected to water heater. 6) Do not expose water heater to rain or water. Resources: Read about flooded water heater. Read about leaking water heater Anode rod How to install electric water heater |
![]() Anode rod: Steel water heater tanks have anode rod that prevents tank from rusting. Periodic inspection and replacement of anode rod will extend life of water heater Resources: Anode rods |
![]() ![]() Dip tube: Cold water enters tank through dip tube Resources: Read about dip tube Remove short water heater nipple New water heater making noise |
![]() For safety, manufacturers make a safe product Each tank has TP valve that releases water when temperature exceeds 170-180º. Temperatures above 180º can damage tank. Resources: How to test and replace TP valve TP valve code |
![]() Drain valve: Plastic drain valve and brass drain valves have 3/4" thread, and fit garden hose Resources: How to replace drain valve Water heater will not drain Leaking water heater |
![]() ![]() Tanks used for solar collectors must be rated for high temperature. Resources: Questions to ask before buying glycol solar system Convert AC water heater to DC water heater Convert AC water heater to DC water heater low voltage Batch solar water heater |
|
Advantages
of electric over gas: Electric heaters cost more to operate than gas heaters. But electric heaters can be maintained to last forever, are cheaper to buy and install, can be installed in small confined areas, can be connected to solar power, can have additional insulation, can be installed in dusty dirty environment like basement, workroom, shop, laundry, are not affected by exposure to household chemicals, do not puff out hydrocarbon byproduct at each home, are easy to fix and alter using generic off the shelf parts Resources: Which is best gas water heater Troubleshoot electric water heater. Solar PV water heater. How to wire thermostats. Compare timers. Is gas clean burning How to maintain water heater Anode rods Two water heaters |
|
![]() The yellow label shows estimated yearly cost for average family of 4. Yearly cost estimates can help when comparing water heaters, but actual cost varies widely. The label also shows 'first hour delivery' of heater. First hour delivery is amount of hot water a fully heated water heater can deliver in the first hour period. It doesn't mean the hot water will last an hour. Calculate first hour Water heater standards changed April 2015. New heaters are about 2% more efficient, except new standard is based on 125° testing temperature instead of older standard 135°. The lower temperature means less hot water in tank, which means lower first hour delivery. Every pound of hot water that leaves the tank is replaced by cold water that is heated and kept heated until next time hot is used. Increase amount of hot water Cost of running electric water heater at various rates 9-ways to save with water heater EF or energy factor is NOT efficiency. EF is a formula for calculting efficiency. There is a subtraction factor: EF = 0.960 – (0.0003 x V). V is volume, or tank gallonage. 40 gallon heater: .96 - (.0003 x 40) = .95 efficiency. As it turns out, the subtraction factor is so small that 30 gallon, 40 gallon and 50 gallon electric heaters each have .95 efficiency. See chart with new and old EF factors Water heating math 9-ways to save with water heater How to wire off-peak water heater. Electric heaters cost more to operate than gas heaters. However, electric heaters can be maintained to last indefinitely, are cheaper to buy and install, can be installed in small confined area, can be connected to solar power, wired several different ways, easily controlled with timer and home automation. How to control water heater withy timer and home automation How to maintain water heater cleaning tank to maintain efficiency Manufactures have added more foam insulation to new water heaters. Most tanks come with heat-trap nipples or heat-trap inserts. Some heat traps can clog or cause whistling. Read about pressure issues and replacing manufacturer's heat-traps How to replace wire on water heater |
Gas
water heater
Unlike electric water heaters, Gas water heaters need supply of air to support combustion |
|
![]() |
How gas water heater works: atmospheric and power vent ![]() Larger image Resources: FVIR flammable vapor system Troubleshoot gas water heater How to adjust temperature on water heater How much does it cost to run gas water heater Which is best gas water heater |
![]() Larger image |
Gas
water heater parts Read about FVIR flammable vapor system Troubleshoot gas water heater How to adjust temperature on water heater |
![]() MultimeterTest for breaks in wire/ Test for voltageMost appliance require 80% rated voltage to function correctly Buy Multimeters at Amazon Electric testers at Amazon Resource: How to test and replace element How to test thermocouple Element tests for 120 volts How to test wire |
Safety
when testing wires: Never touch wet or previously flooded appliance. Never stand on wet surface when working on electric. Never stand on bare soil, put down dry boards. Tape tester leads to wood sticks to keep hands away from power. Use non-contact voltage tester before touching wires. Never touch or lean into any made of metal. Remove metal objects from pockets. Do not use oxygen or fuel accelerants in same room as electrical repairs Resource: Basic house wiring |
![]() Non-contact voltage testerTest for power without touching connectorsNEVER assume power is OFF Buy: Non-contact voltage tester Amazon Electric testers at Amazon Resource: How to test electric power is off |
![]() Twist-on wire connector assortmentsDo not reuse old connectorsBuy: Connector assortment at Amazon Connector assortment at Amazon Resource How to select and install twist-on wire connectors |
![]() Weatherproof wire connectorConnector cavity is full of siliconeBuilt-in cover keeps silicone in place Protect from water, dust etc Buy from my affiliate links Weatherproof size 14 to 6 Amazon Weatherproof size 22 to 8 Amazon Resource How to select and install connectors |
![]() Wrench to apply wire connectors Tighten connector Buy: Wire connector blaster Twist connector wrenches at Amazon Resources: How to twist wire How to select and install twist-on wire connectors |
![]() Buy: Blue for 16-14 wire Yellow for 12-10 wire Resource: How to install terminals |
![]() TerminalsBuy:Terminal kit Blue for 16-14 wire Yellow for 12-10 wire |
![]() Push-on wire connectors in place of twist-on connectorsBuy:Push on wire connectors Amazon Red 3P connector for 10-14 gauge wire Lever connectors for stranded wire at Amazon |
![]() Buy End cutting nippers at Amazon |
![]() ![]() Buy tools: Wire strippers at Amazon Linesman pliers Utility knife at Amazon End cutting nippers at Amazon |
![]() Use solid copper wire Fire inside timer caused by stranded wire Keep enclosure door closed at all times Buy: soldering guns Resource Timer caught fire |
|
|
|
||||||
![]() Contactors/ relays |
|
|
||||||
|
|
|
![]() |
Buy Electronic parts Industrial supplies Tools and home improvement Home and garden Hayward pool Pentair pool Southwire electric |
![]() |
Buy
Tools DEWALT Black and Decker Stanley SKIL Makita Porter-Cable Bosch Irwin Hand tools Klein hand tools Fluke electrical testing Dremel hobby tools Campbell Hausfeld air powered Tekton automotive Powerbuilt automotive Saws and saw blades |
![]() |
Resource: Compare box timers DPDT timers Intermatic Control water heater w/ Z-wave |
![]() |
Resource: Intermatic control centers: and parts Digital control centers and parts Tork control centers and parts Subpanels All control centers and parts Enclosures |
![]() |
Resource: Programmable timers Countdown timers Off delay timers On delay timers Timer modules Din rail Twin & one-shot Woods Intermatic Tork |
![]() |
Recirculation systems |
![]() |
Enter Amazon from