How to light gas water heater
Don't do it
Waterheatertimer.org
is a self-help site
Replace water heater element Figure Volts Amps Watts for water heater 9 ways to save with water heater
How to install point of use water heater Point of use water heater
Compare 16 electric and 3 gas water heater timers Clean sediment out of water heater Troubleshoot Rheem tankless
How to install recirculation system Point of use water heater
T100 series timers Programmable wall timers Auto-off timers Box timers How to set timers
Troubleshoot electric water heater Troubleshoot gas water heater How to wire tankless electric How to wire subpanel
Type 1 and type 2 surge protection surge protection
2016
Search waterheatertimer.org / all results
Search using Find button  

 Tweet button  

How to light gas water heater

Icon gas valve
How to light water heater
How to light water heater/ pdf


Buy

Honeywell gas control at Amazon
American / Honeywell gas control at Amazon
Honeywell gas valve for propane
Honeywell natural gas valve
Reliance NG at Amazon
Reliance LP at Amazon

Replacement instructions
How to test & replace Honeywell gas control valve
How to replace Honeywell gas control valve


Resources:
Adjust temp on Honeywell gas valve
Error codes
Error codes
To reset gas control, rotate dial to OFF, wait 10 minutes for gas to clear. Then relight.
Error code/ troubleshoot/ service manual/ FVIR
Error light blinking 4 times
How to light water heater
How to light water heater/ pdf
How to light Whirlpool energy smart
Bradford White Service manual

More Bradford White service manuals
How to rerplace gas control valves
How to test gas control valve
How to light Honeywell gas control

How to install gas water heater

How to light Honeywell gas valve

Buy
Example honeywell gas control valve at Amazon
Reliance NG at Amazon
Replacement instructions
How to replace water heater gas valve


Resources:
Adjust temperature/ error codes on Honeywell
Range 90 to 156
Hot is 120 F // Very Hot 156
ECO limit 199 F
How to light Honeywell gas valve
Dampered Fury gas troubleshooting codes
Induced draft troubleshoot codes
Error codes
Error codes2
Error codes
Icon gas valve error codes
Service manual
Bradford White service manual 2
Test gas control/ from BW service manual
Power vent water heater issues
Sequence of operation
How to clean burner


How to light water heater

Buy
Buy Intellivent gas control at Amazon
White Rodgers/ Rheem Intellivent gas control
AO Smith intellivent
AO Smith Intellivent at Amazon
AO Smith White Rodgers at Amazon
Intellivent Natural gas at Amazon
Intellivent LP propane gas at Amazon


Replacement instructions
How to replace water heater gas valve


Resources:
AO Smith Intellivent troubleshoot and FVIR test/ pdf
Error codes and adjust temp on Intelli-vent gas valve
How to light water heater
Troubleshoot Intellivent/ pdf
FVIR intellivent troubleshoot .pdf
Intellivent service manual
Intellivent FVIR trpubleshoot and reset
Sample manual
Intellivent wiring
Power direct vent troubleshoot
Sequence of operation
Intellivent error codes-troubleshoot
Promax gas water heater manual

Robertshaw Natural gas control valve
Robertshaw Natural gas
How to light water heater/pdf

Buy
RS Natural gas at Amazon
Camco RS at Amazon
gas valve setting
How to light water heater/pdf

Buy
Gas control valve thermostats at Amazon
Gas water heater thermostats at Amazon
Rheem gas control valve at Amazon
Gas control valve at Amazon
Camco White Rodgers at Amazon
Replacement instructions
How to replace water heater gas valve
Resources:
Service manual
Service manual 2
Service manual 3
How to light water heater/pdf
General troubleshoot manual /pdf
White Rodgers gas control valve replacement pdf
Power vent water heater issues
Magnet testing
Test thermocouple
Gas valve testing
How to light gas water heater
White Rodgers NG replace, install, set temp

How to light water heater/pdf
How to light gas water heater

Buy
Gas water heater thermostats at Amazon
Replacement instructions
How to replace water heater gas valve


Resources:
Robert Shaw models
Robert Shaw troubleshooting/ pdf
Unitrol troubleshoot/ pdf
General troubleshoot/ pdf
General troubleshoot manual /pdf
How to light water heater/pdf
Magnet testing
Test thermocouple
Gas valve testing
Recalibrate gas control/ pdf
How to light gas water heater

How to light Effex water heater

Kenmore with power anode rod
Effex service manual
Suburban water heater service manual
Whirlpool energy smart gas water heater manual
White Rogers thermostat
How to light gas water heater

Troubleshooting/ pdf
How to replace water heater gas valve
SIT gas control valve for water heater
SIT gas control valve for water heater
Larger image
How to light and set temperature SIT gas control
Honeywell electronic water heater controller
Honeywell electronic water heater controllers
Honeywell Smart Valve AO Smith
Honeywell Smart Valve
Larger image
Temperature settings and features
Smart valve error codes
Service manual
Install smart valve & troubleshoot
Robert shaw gas control valve
How to light water heater
General manual with lighting instructions


Robert Shaw 120Volt input gas control valve
Wiper Control and Gas Valve assembly
Triangle pointed upward is 120 degrees F
Replacement/ Buy
Rheem wiper SP20123A thermostat KIT
Wiper SP20123B valve/ no thermostat
To reset: turn the red control knob on and off 6 times within 30 seconds to reset the board.

Resouces
Larger image
Error Codes and troubleshoot
Guardian power vent Robert Shaw error code
Rheem parts list
American power flex parts
General manual with lighting instructions
Replace water heater gas control and FV
Check pressure switch, blower, gas control
Sequence of operation
How to light water heater

Make sure gas is ON
Check that water heater matches type of water heater
Natural gas NG and propane gas LP are different
Check label on side of tank for type of gas.

How to install gas water heater
Water heater safety precautions
Gas water heater ECO

Gas water heater thermostats are usually single-use after ECO trips

Water heater Gas thermostat has Energy Cut Off
When ECO senses overheating inside tank, the ECO trips and shuts off gas.
If water heater burner or pilot has gas, then ECO is not tripped.
Gas valve must be replaced (except Intellivent which can be reset).
ECO must have continuity

Read more
Test ECO on Robertshaw- White Rodgers
Read about resetting intellivent

Buy
Gas water heater thermostats at Amazon
Power ventblower Blower
Buy blower:
Water heater blowers at Amazon


Resources:
Power vents:
Power vent water heater issues
Anode covered by power vent

Blower troubleshoot
Power vent troubleshoot
Troubleshoot hot surface ignition
How to check blower motor
Check blower motor

Pressure switch troubleshoot
Test pressure switch
Air pressure switch testing
Intellivent wiring
Pressure switch replacement
Check pressure switch
 Igniter
How to test piezo igniter
How to check the igniter
Electronic spark troubleshoot
Troubleshoot hot surface ignition
Hot surface igniter troubleshoot
Power vent hot surface ignition



Gas valves
How to set temperature on gas valves
How to maintain water heater





Dusty environments
Avoid dusty environment that will clog air intake, cause unburned fuel, and create fire hazard
-Do not install cold water line above gas valve where condensation drips on valve.  
-Annually clean burner area with wire brush and vacuum cleaner. read1 read2
Troubleshoot and clean gas water heater

Remove chemicals from same room as water heater.
-Chemicals corrode water heater parts and vent pipe. 'Spray propellants, cleaning solvents, refrigerants, swimming pool chemicals, calcium and sodium chloride, household bleach, waxes and process chemicals are corrosive at very low levels with no odor." Read Bradford White Pdf pg2-8    Read Rheem pdf
Trace chemicals
Outlet polarity
If gas valve is connected to electricity, the outlet polarity must be correct
Water heater must be grounded. Poor ground can prevent flame. GFCI circuit can cause short cycling. If outlet is not dedicated or has GFI, other loads such as florescent lighting can cause short cycling.

Unplug cord. Test for continuity between ground prong on plug and manifold tube on gas valve.
Connect water heater to different outlet. Test outlet with circuit analyzer

Avoid dusty environment that will clog air intake, cause unburned fuel, and create fire hazard
-Do not install cold water line above gas valve where condensation drips on valve.  
-Annually clean burner area with wire brush and vacuum cleaner. read1 read2
Troubleshoot and clean gas water heater

Remove chemicals from same room as water heater.
-Chemicals corrode water heater parts and vent pipe. 'Spray propellants, cleaning solvents, refrigerants, swimming pool chemicals, calcium and sodium chloride, household bleach, waxes and process chemicals are corrosive at very low levels with no odor." Read Bradford White Pdf pg2-8    Read Rheem pdf
Trace chemicals
Gas and electric water heaters Support the economy:
Buy water heaters  from my associate links:

50 gallon Gas water heaters at Amazon
40 gallon gas water heaters at Amazon
50 gallon Electric water heaters at Amazon
40 gallon electric water heaters at Amazon
Hybrid / heat pump/ water heaters at Amazon

Resources:
How to install gas water heater
Troubleshoot gas water heater
Troubleshoot electric water heater
Intermatic control centers Intermatic control centers:
+ manuals and parts


Including Z-wave
box timers Compare box timers

Control with Z-wave
programmable timer Compare programmable timers

Control water heater with programmable wall timer
Countdown timers Compare countdown timers

Control water heater with countdown timer
Compare power packs

E-mail: geno03245w@gmail.com
My response might end up in spam folder, check email folders
Site map
Follow newest idea on twitter
Privacy policy
Search