Intermatic Digital
control centers, parts and manuals: Control panels accept any combinations of T100M, P1353ME, P4243ME or RC2000M or PF1000M Series mechanisms Home
Search waterheatertimer.org / all results Tech support options |
9 Basic
Components |
|
3-channel PE153 Larger image Image of back of timer Buy: P1353ME timer replacement Buy PE153 timer plus enclosure PE153 series 3-channel timer PE153P plastic enclosure/ P153PF plastic enclosure/ with freeze PE153F metal enclosure/ with freeze Resources: P1353ME Manual P1353ME Manual 2 P1353ME Manual 3 Wiring diagrams P1353ME Sell sheet PE153-Sell-sheet.pdf |
1. P1353ME Programmable timer P1353ME is a 3-circuit, 24 hour programmable timer with 3 on-off events per day, per circuit, repeated each day. The 3 circuits can control 3 separate loads (pump, lights, spa etc) ... and control each with same or different schedule .... or the P1353ME can control 2-speed pool pump and 1 other load depending on which of the 6 modes is set. Has a Countdown feature. Use 3 white buttons on face of timer to manually override programming, such as switching on the pool pump. Each of the three 17 amp relays is rated for 1 Hp pump/motor at 120V AC, or 3 Hp at 240 volt AC. Buy PE153 Buy: P1353ME timer replacement The electronics are protected by a fuse located on back of timer. Image of back of timer Default input voltage is 120V AC. Or use jumper on back to select 240 volt AC. This is the voltage that powers the timer at terminals 1 and 2. Example wiring The 3 relays at terminals 3 thru 8 are dry; They receive no voltage when timer is connected to power. Relays can control either 120V or 240V AC. Power must be off before any wiring is done or accessories added. There are accessory connections on back of timer for firemen's switch and Intermatic 178PA28A freeze sensor. See image of installation Firemen switch turns off gas heater 15-20 minutes before pump is scheduled to turn off, while freeze sensor will turn pump ON if temperatures drop near freezing. Buy: 178PA28A freeze sensor Resource How to wire P1353ME 3-circuit timer |
P4043ME actuator only PE140 actuator in 3R enclosure Larger image Buy P4043 Control 1-2-3 motorized valve actuators Resource: P4043 manual |
2. P4043ME and PE24VA Valve
actuator P4043ME can control two or three PE24VA motorized valve actuators to toggle the pool pump water flow between swimming pool and spa. See image How it works: Connect 120V to white-black wires on back of the P4043ME, or connect 240V to red-black wires. Connect same 120 or 240 volt power to the remote switch connection for remote operation via ordinary single pole switch, spring-wound countdown timer, Intermatic radio receiver, home automation etc, or connect the remote switch terminals to the 5-channel PE653RC multiwave receiver shown below and use Intermatic hand held remote.. If a momentary switch, latching contactor etc is chosen instead of ordinary on-off switch, then move jumpers on back of P4043ME from 1-2 to 2-3. After connecting 120 or 240 volt power to the P4043ME, the internal transformer produces safe 24 volt AC output. When the 24 volt outputs are activated via the remote switch or the 5-channel PE653RC receiver shown below, it sends 24 volt through the 20' long 3-wire cable going to 2 or 3 PE24VA motorized actuators that rotate the water valves (installed as part of the pool-spa plumbing) causing the water flow to toggle from pool to spa. Read more |
PE24VA valve actuator Buy: PE24VA comes with 20 foot cable. If longer length is needed, cut cable in half, plug ends into PE24VA and P4043 and then splice using 3-strand thermostat wire. Resource: PE24VA Manual PE24VA actuator can be controlled with switch located on the PE24VA, or by manually rotating handle. |
Larger image Hand held PE953 3 AA Battery operated remote control. 5-channel, or 5 circuits ... with 1 button for each circuit |
3.
PE953 Hand held Remote For people wanting hand-held wireless control over pool functions, Intermatic makes the hand held PE953 remote control that works with the 5-circuit PE653RC multiwave transceiver shown below. Works with 'MultiWave functions and other Z-Wave devices.' The hand held PE953 will communicate with one PE653RC receiver to control up to 5 loads including a P4043ME valve actuator and 3 additional loads or a 2-speed pump and 2 additional loads. The hand held remote can be programed for on-off times, or use the 5 override buttons located on face of remote. Buy:: PE953 Resource: Current PE953 manual Hand held P953 manual Older PE953-PE650 instruction manual Multi-wave installation manual Set up instructions Multi-wave sell sheet with wiring Multi-wave sell sheet2 with wiring |
Larger image 5-channel PE653RC receiver |
4.
PE653RC 5-channel multiwave receiver The 5-channel (with 5 relays) PE653RC multiwave receiver comes in a durable plastic weatherproof enclosure with override buttons located on face. The 5 relays can control 5 different 120-240 volt circuits, with 5 different schedules, or control 2-speed pool pump and 3 other circuits. It can control 1 or 2-speed motor, low voltage lights, blower etc. Relay 1 is rated 17 amp full load, relays 2-5 rated 10 amp full load. Rating sheet Loads are hardwired to the PE653RC What to do: Install the 5-channel PE653RC receiver on top of any control panel by drilling 1-3/8" hole and install on top of any enclosure, and then program all operations into the hand held PE953. To avoid drilling, buy the PE653RC package The hand held remote wirelessly signals operations to the PE653RC receiver. The 5-channel PE653RC can also be manually operated by pushing any of the 5 buttons on face of PE653RC. Use voltage selector to choose the incoming 120 or 240 volt. Three of the five relays are 'dry' and can be used for either 120V or 240V. Buy: ' PE653RC PE653RC all-in-one package Resource: Manual Wiring Parts sheet |
Larger image Large image of wiring P5043ME Expansion module Resource P5053ME Manual |
5. P5043ME Expansion
module The P5043ME Expansion module lets you control multiple pieces of equipment like a pool, spa, fountain etc using the hand-held PE953 hand-held remote and 5-channel PE653RC. You can control 2 heaters, plus control up to 4 PE24VA actuators to toggle water flow between pool and spa, plus control 1 or 2 speed pool pump. P5043ME requires 240 volt input. Outputs are safe 24 volt AC. What to do: Install the 5-channel PE653RC on top of any any Intermatic enclosure or control center. Snap the P5043 expansion module into the enclosure. Connect low voltage (24 volt) communication cable, and valve actuator cables, paying attention to polarity. Then use the hand held remote to control up to 4 actuator valves (pool/ spa/ fountain), 2 different heaters (one for each pool and spa), control pool pump. See image |
Larger image PE103 timer only P1403ME timer and enclosure |
6.
PE103 and P1403ME Programmable
timer with seasonal adjustment P1403ME 24-hour timer is for 1-speed or 2-speed pump plus 1 additional circuit. The timer has automatic daylight saving with seasonal timing adjustment (10 to 120 minutes). Imput voltage 120, 207, 240, 277 volt AC, 50-60 Hz is applied to terminals AC IN 16 amp relays for 1-speed or 2-speed pump, plus 1 additional 16 amp relay. 3 timed ON and 3 timed OFF events per 24 hour period, 1 on/off event for high, low and auxiliary circuits, and varies automatically with seasonal adjustment. 4-SPST all 4 relays are turned on-off with same schedule. ''PE103/ P1403ME timer is a programmable pool and spa three-circuit device used for two-speed pumps and auxiliary equipment. The timer features a programmable Seasonal Adjust offset that automatically adjusts filter pump ON/OFF schedules according to season'' .... example: high speed operates fewer hours in winter months vs summer months to save energy. Buy: P5043 Resources P1403ME-manual Technical data .pdf Wiring diagrams |
7. Air temperature sensor "Add the Intermatic Freeze or Air Temperature Sensor 178PA28A to installations where below-freezing outdoor temperatures are a concern. The sensor is designed to protect the pool and spa equipment and plumbing against freeze damage. The sensor plugs into the circuit board on the back of the P1353ME and turns ON the filter pump when air temperature drops below the programmed temperature. The freeze programming mode will not appear unless the sensor is plugged into the clock." Buy: 178PA28A Resources 178PA28A manual I-wave-accessories/ parts pdf |
8. Water thermostat PA122 water temperature sensor Wiring kit 156PA12976A Buy: Intermatic PA122 PA122 manual |
9. PE650 antenna receiver with
PA118
antenna/
Discontinued PE153RC all-in-one timer, remote and receiver Discontinued Control one or two three-circuit P1353ME timers -or- one or two P4243 valve/pump actuators -or one of each P1353ME and P4243 The main function of the discontinued PE650 Panel Mounted Transceiver is to take commands from the Wireless Hand Held Transceiver (PE953) and hand them off to two mechanisms (P1353ME and/or P4243ME). Buy PE650 transceiver Resource Wiring PE650 instruction manual Sell sheet Sell sheet Parts sheet Image of wiring PE953-PE650 remote transceiver instruction manual |
Current and Discontinued Control Centers | |
PE10000
series/ Discontinued No breaker slots Dimensions 15" wide x 15.4" tall and 4.7" deep (working depth 4.24") / Comes with one P1353ME 3PST 3-channel digital timer. 3-channel means the timer has 3 separate programs, so the timer can be programmed for 3 different 120-240 volt loads (light, pump, etc) and each load can have a different on-off schedule. Nema 3R outdoor (weather-resistant) enclosure with 2 low voltage knockouts and 10 electrical wiring knockouts located on bottom for conduit with ample space for wiring. Mount at least 12" above anticipated snowfall. Enclosure code. Enclosure includes low voltage raceway to isolate low voltage wires from residential 120-240 volt wires, 3 spaces for optional switch and GFCI outlet. Can be wired for 120 volt or 208-240 volt. What is 208 volt. Freeze sensor option 178PA28A can plug into back of 3-channel P1353ME ... automatically turning on pool pump when air temperature drops below 40°F (or set point you program into timer). Enclosure comes with additional space can be used for a T100 series timer to control lights, or use space to add another 3-channel P1353ME or add a P4243 actuator control that can toggle pool pump between pool and spa. Resources and manuals PE10000 manual |
PE25300
series/Current
nmodell 60 amp/ 4 breaker slots Comes with P1353ME 3PST 3-channel digital timer 16.8875" x 10.875" wide x 4.75" deep Nema 3R plastic weather-resistant indoor-outdoor enclosure with 11 knockouts for conduit. Plus 4 spaces for 1" wide push-down circuit breakers ... or increase capacity and install tandem breakers. Spec Sheet Mount enclosure at least 12" above anticipated snowfall. 60 amp is maximum amount that can be pulled off the busbar located inside control panel. Install 60 amp breaker inside the household main breaker panel, then run two hot wires plus Neutral and ground using 6 gauge copper wire to the PE25300 control panel. This wiring gives 120-240 volt at the control center to power 240V pump plus 120 volt for lights, GFCI etc. Siemens 80 amp breaker The discontinued PE25300RC model (shown below) comes with hand held P950 remote control that wirelessly interfaces with the 3-channel P1353ME to manually override pump or spa circuit |
PE35300/
22.87"
x 14.875" wide x 4.75" deep Current
nmodel 80 amp/ with 8 breaker slots PE35300 comes with 3-channel P1353ME digital timer that can control 3 separate loads, or a 2 speed pump plus additional load ....with 8 circuit breaker spaces, higher amperage rating to control more auxiliary devices. Nema 3R plastic weather-resistant indoor-outdoor enclosure with 11 knockouts for conduit. Plus 8 spaces for 1" wide push-down circuit breakers ... or increase capacity and install tandem breakers. Spec Sheet Mount enclosure at least 12" above anticipated snowfall. Advantage of PE35300
is 80 amp capacity, plus extra space inside enclosure for snapping in
another 3-channel P1353ME timer, or a 40 amp T100 series mechanical timer for
lights etc ...30 amp digital 2 channel ET1800 series timer, sprinkler-irrigation timer, etc.
80 amp is maximum amount that can be pulled off the
busbar located inside control panel.Install 80 amp breaker inside the household main breaker panel and and run two hot wires plus Neutral and ground using 8 gauge copper wire to the PE35300 control panel. This wiring gives 120-240 volt at the control center to power 240V pump plus 120 volt for lights, GFCI etc. Siemens 80 amp breaker Note: all Intermatic control centers are modular ... with parts sold separately ... so user can start with the PE35300 and add additional components to make whatever configuration matches their pool equipment. Buy: PE30000 enclosure/ no timer PE35300 with P1353ME timer Intermatic PE35300 178PA28A Air temperature freeze sensor that snaps into P1353ME timer P1353ME timer mechanism-only PE4043ME valve actuator controller PE24VA valve actuator Resources and manuals PE30000 series manual Sell sheet Dooir label P1353ME timer manual/ with wiring applications pdf How to wire Intermatic control center breaker busbar PE30000 Parts sheet / pdf |
PE20000RC
series
Discontinued 60 amp/ 4 breaker slots/ multi-wave 16.5" x 107/8" wide x 4.25 deep The PE953 hand held controller is made specifically to interface with the 5-channel PE653RC contactor.... but reportedly can operate a single z-wave device, and 4 channels on the PE953. Enclosure comes with space for 4 circuit breakers, plus 3 optional spaces for switch and GFCI outlet for extension cord etc. The optional PE24065RC is actuator control that can toggle pool pump between pool and spa, and includes two actuators that attach to valves and rotate both valves to switch water flow from pool to spa. 60 amp panel is maximum amount of breaker load that can be put onto the busbar. Use 60 amp breaker inside main breaker panel and run 6 gauge copper wire to the Intermatic control panel. Use 6-2 with ground if all equipment is 240 volt. Use 6-3 with neutral and ground if equipment is 120 volt and 240 volt or if GFCI is used at control panel. |
PE30000RC
series/ Current
nmodel 80 amp/ 8 breaker slots/ multi-wave 16.5" x 107/8" wide x 4.25" deep PE20000RC series comes with heavy-duty Nema 3R (weather-resistant) outdoor enclosure with knockouts for conduit and space for wiring. Mount at least 12" above anticipated snowfall. Programming the remote control ... PE953 remote control manual/ pdf The hand-held PE953 is newest version of remote control, and weather resistant for pool environment. All operations are programmed into the PE953 remote control, which has manual override button for each operation.... Wiring applications The PE953 programming is automatically broadcast (wirelessly) to the PE653RC 5-channel contactor that is mounted to top of enclosure. The 5-channel contactor also has manual override buttons located on front face ... so the PE20000RC series is a 5-channel multi-wave (remote control) system that can control 5 separate devices including 120-240 volt loads such as pool pump, cleaner, and lights ... plus a set of low voltage terminals to switch pool lights on-off. Code requires all lighting that can come into contact with water to be 24 volts, which is considered below human sensation threshold of around 40 volt.
|
Control center with multi-tap transformer Pool panels with transformer/ discontinued PE45343RCT1 / 100 watt PE45343RCT3 / 300 watt |
Control
centers with
Transformer:
PE30000T3
series/
PC30000 series enclosure with 300 watt transformer /
80 amp 8 breaker slots Empty enclosure (subpanel with 8 breaker slots) without timer or control/ with 300 watt low voltage transformer for pool lights Buy: PE3000RT enclosure with 300 watt transformer / 8 breaker slots T40000RT3 enclosure only/ with 300 watt transformer/ 8 breaker slots PE45343RCT3 with P1353ME timer/ remote control and actuator/ 8 breaker slots / plus 300 watt low voltage transformer Multitap low voltage transformer for underwater lights, and/or pathway lights. Transformers are efficient & reliable with no moving parts and should not need replacement. The shielded, multitap 12-13-14 volt transformer lets you adjust for longer length of wire or more lights or brighter lights. Low voltage is for electrical safety. Do not wire underwater lights with household voltage. 119T267 100 watt replacement transformer 119T340 300 watt multi-tap transformer Resources: PE3000T3 Parts sheet PX series transformers and manuals Image of transformer wiring More control centers with transformers |
RC2163BFE
remotely operated control system
Current
nmodel/ 100 amp/ 8 breaker slots/ control with remote swich 16-3/4" high x 10-7/8" wide x 4-3/4" deep Nema 3R plastic weather-resistant indoor-outdoor enclosure Cut-away view ''Operates Single Speed Filter Pump, Up to Three Valve Actuators.' Comes with 2 actuators for pool-spa control. ''Dual Heater Thermostats'' .... when pool and spa have different temperature settings. 3-way Heat Selection: -Spa Only -Pool and Spa -No Heat. Has low voltage transformer with direct connection and raceway for pool lights. Connection point for freeze sensor to turn on pump if temperature drop near freezing. Timer has 8 on-off programs per day. Or the operation can be controlled by installing a remote switch, or using air switch, using radio receiver. See radio receivers. Timer has battery that lasts 3-years. Timer and other parts are replaceable for long serviceability. RC2163BFE has 8 breaker spaces with 100 amp capacity. Can operate a 120-240V single speed filter pump (1 Hp @ 120V, 3 Hp @ 240V), 1-2-3 valve actuators, and dual heater thermostats. Timer automatically controls schedule, or override using buttons on timer face, or use a remote switch or use a remote countdown timer, or any type of automated control. Valve actuator rotates valves so pump can run either the spa or the pool. Set timer to run pump, and toggle between circulating water through pool or through spa. Use remote switch to override timer.'
|
|||
RC2163FE/
100 amp/ 8
breaker slots/
space for 3 timers
With P1353ME 3PST 3-channel digital timer Discontinued Manual/Resource: RC2163E wiring |
PE953 MultiWave controller replaces the I-Wave PE953 controller.shown below |
PE953 multi-wave remote control Intermatic says: "The primary function of the PE953 MultiWave wireless hand-held controller is to both transmit user commands and receive equipment data from a variety of different devices, including the PE650, PE653RC, specific OEM equipment and any Z-Wave compatible transceiver device.The PE953 is an all-in-one multitasking controller capable of communicating with all the above devices by toggling the screens on the controller to the appropriate device. With the addition of the new backlit display and improved features; the new PE953 MultiWave controller replaces the I-Wave PE953 controller. " Remember: PE953 is not a general purpose z-wave controller for your household z-wave network, but can control 1 zwave device. It is primarily designed to use with Intermatic multi-wave.' Buy: PE953 hand-held transceiver Resource Current PE953 manual Hand held P953 manual Older PE953-PE650 instruction manual Multi-wave installation manual |
5-circuit PE653RC receiver PE653RC control system Large image of PE953 remote multitasking controller capable of communicating with PE650 transceiver antennae and PE653RC and any Z-wave device by toggling the screens on the controller to the appropriate device |
PE653RC
Multi-wave/ Choose 120V-240V/ control 5
circuits using manual buttons
or using remote control 1) Filter pump 2) Low speed 3) Cleaner 4) Pool light 5) Gas heater/ same appears remote control PE653RC has connections for air temperature sensor, water temperature sensor For controlling 2-speed and variable-speed pool pump with PE953 remote control/ hand-held transceiver Buy: PE953 hand-held transceiver PE653RC wireless control & transmitter for 2-speed pumps PE653RC 5-circuit receiver Resources Multi-wave installation manual Set up instructions Multi-wave sell sheet with wiring Multi-wave sell sheet2 with wiring Multiwave sell sheet PE953 manual Typical control panel wiring #2 PE653RC parts sheet Large image showing features and wiring Service mode |
Larger image Larger image |
PE653RC installed 5-channel receiver with push-button overrides for each channel. PE653RC can control 5 loads or 5 circuits... this can become a lot of wiring. The PE653RC comes complete with weathertight wiring-and-junction box that has plenty of space to make multiple wire connections Weathertight wiring-and-junction box has 4 knock-outs for 1/2" or 3/4" conduit Buy: PE953 hand-held transceiver PE653RC wireless control & transmitter for 2-speed pumps PE653RC 5-circuit receiver |
PE653RC retrofit Convert any Intermatic timer or outdoor enclosure into PE653RC Drill 1-1/4" hole in top of enclosure using tapered drill bit. The enclosure becomes junction box for wiring the receiver with ample wiring space to match the 5 channel PE653RC. Buy Metal cutting tapered hole saw PE653RC wireless control & transmitter for 2-speed pumps PE653RC 5-circuit receiver PE953 hand-held transceiver Resources Multiwave sell sheet Image of wiring Wiring applications Intermatic enclosures |
P5043ME
Expansion module See larger image Large image of wiring Control 2 heaters, control 4 actuators (for pool-spa-and fountain), plus remote switch override Works with hand held PE953 remote control and the 5-channel PE653RC receiver. Use remote control or buttons on face of 5-channel receiver to operate expansion module. If you have 3 pieces of equipment like a pool, spa and fountain etc, and 2 heaters, then P5044ME can automate the equipment and toggle water flow and heaters for each piece of equipment, plus control 1 or 2 speed pool pump. P5043ME expansion module requires 240 volt input. Outputs are safe 24 volt AC. What to do: Install the 5-channel PE653RC on top of control center (or any Intermatic enclosure). Snap the P5043 expansion module into control center (or any Intermatic enclosure). Connect low voltage (24 volt) communication cable, and valve actuator cables, paying attention to polarity. Then use the hand held remote for control over 4 actuator valves (pool/ spa/ fountain), 2 different heaters (one for each pool and spa), and control pool pump. Resource: P5043ME manual |
Larger image P103 |
PE103-P1403ME
seasonal timer 1 or 2 speed pump with automatic seasonal adjustments Metal outdoor box "The PE103/P1403ME timer is a programmable pool and spa three-circuit device used for two-speed pumps and auxiliary equipment. The timer features a programmable Seasonal Adjust offset that automatically adjusts filter pump ON/OFF schedules according to season." Buy: PE103 1-2 speed Seasonal timer PE103 1-2 speed Seasonal timer P1403ME 1-2 speed Seasonal timer Manual: PE103-P1403ME manual and wiring Example 240Volt wiring Safety kit instructions |
Larger
images
Wire P1353ME timer for 2-speed pump
P1353ME single speed |
Wiring
illustrations / P1353ME Resources: How to wire P1353ME timer Another wiring diagram Another wiring diagram Benefit of 2-speed pool pump/ pdf |
Install
wiring devices inside the enclosure First remove rectangular knock-out(s) in dead front. Remove front panel Remove hex head screws from enclosure and install 21T156A stand-offs in place of screws. 6-32 Attach deco-style wiring device to standoffs. Replace front panel Buy: 21T156A stand-offs pack 4 each / 21T166A stand-off 3" long / pack 2/ Resource: How to wire control center GFCI |
Parts
sheets: Resources: PE15300 Parts sheet / pdf PE20000 parts sheet PE25000 parts sheet PE30000 Parts sheet / pdf PE20000 Parts sheet PE20000 Parts sheet |
PE3000T3 Parts sheet PE1500RC parts sheet / pdf PE40000 Parts sheet PE45000 parts sheet I-wave-accessories/ parts pdf PE653RC parts sheet PE153 parts sheet / pdf |
Old models: PE153WF 100' wired remote + freeze PE153P plastic outdoor box PE153W plastic box + 100' wired remote PE153WF plastic box + freeze + 100' wired remote |
Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |