How to control motor with two switches
Resource: safe electric wiring
30 amp switches 30 amp double-pole 30 amp DPDT Ordinary 15-20 amp switches 15 amp pilot light
switch
Cooper 30 Amp switch
Single-pole/ 2-pole on-off switches
Buy:
30 amp 2-pole switch
30 amp industrial grade

Heavy duty double-pole switches to turn off both hot wires in 240 volt circuit
Buy:
30 amp motor switch
40 amp motor switch
Leviton motor switch
Double pole double throw 30 amp switch
Buy:
30 amp DPDT switch

Resource:
Use this switch to toggle water heater between 120-240 volt
single-pole switch
Ordinary 15-20 amp toggle switch
Buy:
15 amp switch
20 amp switch

Indicator light shows when Load is ON
Buy:
Pilot light switch
Resource:
How to wire pilot light switch
Use only 600 volt wire.
Lamp cord, extension cords are not rated 600 volt.
Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional.

30 amp breaker use 10 gauge /
120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker.

Orange/ #10 gauge wire, with ground ... 30 amp capacity. Safe maximum: 30 x 80% = 24 amps.
Buy:
10-2 gauge/ 30 amp
10-3/ 30 amp
Southwire electric tools
Yellow 12 gauge 20 amp
120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire.
... cannot be connected to 30-40 amp breaker. 1

Yellow/ #12 gauge wire, with ground ... 20 amp capacity. Safe maximum 16 amps.
Buy:
12-2 gauge/ 20 amp
12-3/ 20 amp

NMB is house wiring
UF is underground
Rolls of stranded wire
HOOK UP Wires
White 14 gauge 15 amp
120 volt 15 amp outlet, AFCI, GFCI, timer, switch etc can be installed on 15 or 20 amp breaker. Never connect 15 gauge wire to 20-30-40 amp breaker.

White/ #14 gauge wire,  with ground ... 15 amp capacity. Safe maximum 12 amps.
Buy:
14-2 gauge/ 15 amp
14-3/ 15 amp

NMB is house wiring
UF is underground
50-60 amp breaker use 6 gauge /
240 volt 50 outlet can be installed on 50 amp breaker only
6-2 wire
Buy:
6-2 wire
Southwire electric tools
NMB is house wiring
UF is underground
40-50 amp breaker use 8 gauge /
240 volt 40 amp outlet can be installed on 40 or 50 amp breaker only
6-2 wire
Buy:
8-2 wire
Southwire electric tools
NMB is house wiring
UF is underground
     
Copper ground wire.
Every device, load, metal enclosure etc must be grounded. Ground wire must be continuous throughout installation, never switched on-off, never used as a Neutral wire.
Generally ... use same size as other wire in circuit
Buy:
12 gauge copper ground wire
Ground wire
Green ground wire
Ground pigtails
Ground rods/ ground clamps at Amazon
armored cable
Non metallic flexible cables must carry ground wire, but do not have hazard of short circuit causing injury from shock.

Armored steel cable can be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure.

All conduit ...metal, plastic ... flexible and rigid ... must be attached to structure, and attached to enclosures, boxes.
Movement, damage and deterioration are major cause of electrical failure.
Buy:
Non-metallic flexible conduit
Power whip
Armored cable
Southwire armored cable cutter
Pull boxes
Southwire armored cable cutter
Electrical tools must be insulated.
Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off.

Buy:
Electrician tools kits
KLEIN TOOLS
Tools kits
IRWIN tools
KNIPEX

Telephone cable knife
Low Voltage Mounting Bracket for Telephone
stranded wire
600 volt 12 ga Stranded wire ot THHN wire is good for conduit with multiple wires ... but stranded cannot be installed under screw terminals on outlets, switches, timers etc without risk ... of heat causing splayed strands ....that come loose ... and begin to arc. Connect stranded to short piece of solid copper wire, and attach solid to screw terminal. Do not solder residential or commercial wiring.

Project wire, extension cords, thermostat, bell and automotive wire are not rated for residential or commercial wiring. Only wire maked 600 volt can be used for permanent household wiring.
Buy:
Southwire 600 volt stranded wire
Rolls of stranded wire
HOOK UP Wires

Protect wiring from damage
Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable.

-Code says: Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15
Buy
End cutting nippers at Amazon


Electrically insulated tools
When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistance and heat on wire and creates possible weak point.
Buy tools:
KLEIN TOOLS
Wire strippers at Amazon
Electric Wire Stripping Machine
Linesman pliers
Utility knife at Amazon
multimeter
Multimeters
Voltage is tested across two separate wires. Ohms or resistance is tested across both ends of same wire. Amperage is tested along one or two points on same wire.
Buy:
Analog multimeter
Multimeters at Amazon
Klein multimeter
Electric testers at Amazon
Clampmeter for testing amp flow on line

GFCI circuit breaker
A GFCI circuit breaker will protect all boxes on circuit.

Circuit must be grounded. Ground wire must be continuous and connected to each piece of equipment.

White wire on circuit breaker must be connected to Neutral busbar inside the breaker panel.

Buy
GFCI circuit breakers
Push down
single-pole breaker
1" wide Push down breaker
Plug-in breaker
Buy single-pole:
Choose from 15 to 60 amp
Eaton CL series
Siemens 15-60 amp

Single-pole tandem breaker
Tandem breakers
Push down
double-pole breaker
2" wide Push down breaker
Plug-in breakers
Buy double-pole:
Choose from 15 to 125 amp
Choose from 15 amp to 200 amp
Eaton CL series circuit breaker
Siemens circuit breaker
Double pole GFCI
Control motor with two switches
3-way switches control 240Volt motor
No Neutral wire needed
Ground wire not shown
Wiring applies to any 240Volt load


Buy:
Contactor
ANL fuseholder
Buy fuseholders at Amazon

Resources:
Fuseholder
Contactors
Terminals
Wire and breaker size chart
More motor resources
3 way switches control water heater 3-way switches control 240Volt water heater
Use ordinary 15 amp 3-way switches from hardware store
Must add busman fuseholder with 15 amp fuse. This will protect line and switches from over-amp and fire.
240Volt coil on DPDT contactor.
Buy:
Contactor
ANL fuseholder
Buy fuseholders at Amazon

Resources:
Contactors
Fuseholder
Control motor with two switches For your 3-way switches ... each switch is rated by voltage...
Cheapo box store 3-ways are rated 120V (embossed in the metal on switch) and are not suited for project.
Better switches are rated 120-270 .... and these are rated for 120-208-240-277 volt ... but not higher voltages like 415, 480 etc
Get a couple 3 way switches ... the common screw will be a different color like black ... don't let the location of the common screw confuse you.
The other two screws will be brass color ... just run two wires across and connect those screws ... then forget em...

After that is done, connect a wire to the dark screw or common screw and run it over to your contactor.
Then connect aother wire to the other common screw and run it over to the contactor.

Packard contactor 2-pole 40 amp contactor
With removable dust cover on top.
Contactors.
Select voltage needed to control coil.
Buy 2-Pole 40A resistive
120Volt coil At Amazon
240Volt coil At Amazon
24 volt coil at Amazon
Mars 2-pole and 3-pole contactors at Amazon

Resource:
Fasco info sheet
contactor
Larger image
What is a contactor?
Contactor is a switch. It is rated for high amp loads.
High amp causes heat. Heat will damage regular electrical parts.
Timers and Buy Metal
Bud industries 6x6x4
Nema 3R Outdoor box
Hinged door/ 6x8x4

Polycarbonite enclosure
Bud industries boxes at Amazon
Arlington boxes at Amazon
wall switches can be damaged by high amperage.
Each switch and timer has amp rating.
Contactors are rated for more amps than ordinary wall switch or timer.

The electrical circuit lasts longer when a contactor is used because contact points on a contactor are designed to switch high amp loads without melting or being damaged by heat.
The electromagnetic coil can be switched on-off using ordinary wall switch or timer.
When voltage is applied to coil, then contact points close, and heavy amp circuit turns on.
This lets you control heavy amp loads using ordinary wall switch or timer.
Use correct size large screwdriver or #3 square head driver.
Use T handle driver instead of cordelss tool for best torque without damage
Cordless driver can sometimes crack apart circuit breaker, outlet, switch etc, and might slip from screw before wires are firmly attached.
Buy:
Square drive set
T handle nut driver
Ratchet screwdriver

Resources:
Safe electric wiring
Color code wire
Extension cord code
45EG20AF in box
Larger image
2-pole 40 amp contactor in 6x6x4 enclosure
Using #8-32 x 3/4" bolts
Install contactor at angle leaves room for wire

This is DPST contactor
Double pole, single throw.
So the contactor is 2-pole. It can turn off 2 wires.
And single throw because both poles are on-off at same time.
So you can switch both wires in 240 volt circuit.

Buy Metal
Bud industries 6x6x4
Nema 3R Outdoor box
Hinged door/ 6x8x4

Polycarbonite enclosure
Bud industries boxes at Amazon
Arlington boxes at Amazon

Resources:


How to wire contactor for water heater
Enclosures

30 amp DPDT switch

For certainty, always Test switch terminals using continuity tester before wiring.
24 amp safe maximum
Practical wiring diagram
Wire diagram
Toggle water heater between 120Volt and 240Volt
Max 4500 watt non-simultaneous water heater
Use 240Volt during times when electric prices are lower, and faster recovery is needed. Use 120Volt during peak prices when less hot water is used
Bring 120Volt from nearby outlet that has 12 gauge wire, or install lower watt elements if wire is only 14 gauge.

Using 30 amp Double Pole Double Throw switch
Ordinary 3-way switch will do same job, but without center off
Also called: 30 amp 2 pole DPDT switch
Buy double-pole double throw 30 amp
2 DPDT switch with center off at Amazon
2 DPDT switch with center off at Amazon

Connect 120Volt wires as Hot and Neutral. Black connects to 120Volt circuit breaker and White connects to neutral busbar.
Connect 240Volt wires as Hot1 and Hot2. Both wires connect to 240Volt breaker.
Resources:
How to wire water heater for 120 volts
Select correct wire and breaker
Figure volts amps watts for water heater
See inside main breaker box
Two water heaters
30 amp maximum current/ safe limit 80% = 24 amps
Over-amped switch will feel warm/ hot
How to control water heater with ordinary switches
water heater 30 amp switch Buy:
Leviton 3-way 30 amp switch
Leviton 3033 at Amazon
30 amp 3-way switches at Amazon

Buy Double-pole switches
Leviton 3032-2w double pole 30 amp at Amazon
Leviton MS302-DS 30 amp double-pole switch at Amazon
2-pole 30 amp non-fusable safety switch/ power cut-off
30 amp switches at Amazon
Buy double-pole double throw 30 amp
2 DPDT switch with center off at Amazon
Resources:
Twisting wires
wire connector basics
Rated 25 amps, max 5500 watt water heater
5500 Watt elements draw 23 Amps
4500 Watt elements draw 19 Amps

Resources:
Figure volts amps watts for water heater
Read label on water heater
control water heater with switch 240V water heater can be controlled directly with a 30-amp double-pole switch
Rated 25 amp
Turn off both Hot wires.
Not necessary, since turning off 1 hot wire works fine. Read above

Buy double pole. single throw, 30 amp switches:
Leviton 3032-2w double pole 30 amp at Amazon
Leviton MS302-DS 30 amp double-pole switch at Amazon
2-pole 30 amp non-fusable safety switch/ power cut-off
30 amp switches at Amazon

Resources:
Twisting wires
wire connector basics
Control 277 volt motor or pump or water heater with timer
No Neutral wire needed for timer

Buy:
Intermatic ST01c timer at Amazon/ 1 year warranty
Ei600 5-year warranty timer at Amazon
CR2 replacement battery at Amazon

Resources:
How to program and wire ST01 timer
Load ratings for Intermatic timers/ pdf
Load rating for ST01 timer: 120V ac, 6A, 208-277V ac; DC Loads 4A 12V dc, 2A 28V dc; Motors 1HP 120VAC, 2HP
240V ac, Ballast 16A 120V ac, 208-277V ac; Resistive 20A 120-277Vac.

Buy:
Contactor
ANL fuseholder
Buy fuseholders at Amazon

Resources:
Fuseholder
Contactors
Terminals
How to install timer: Project
More wiring for ST01C
Same wiring applies to Intermatic Ei600
Intermatic timers and manuals
ST01 timer controls motor

30 amp safety cut offFused safety switch
Cuts power to one or both legs of 240V circuit.
Rated for indoor.
-3 Hp motor, 17 amps, use 30-60 amp safety switch
-30 amp water heater, use 30-60 amp
Since water heater is on a breaker, then either fusible or non-fusible is fine
Buy from my affiliate links:
L211N 30 Amp 120/240-Volt/ 30A /one plug fuse
L221N 30 Amp 240-Volt/ 30A/ two plug fuses
As illustrated
2-pole outdoor / 60 amp/ non-fusible
2-pole outdoor / 30 amp/ non-fusible

2-pole indoor / 30 amp/ fusible
2-pole indoor / 30 amp/ fusible

Heavy duty safety switches at Amazon

Resource:
L111N specs Single pole 30 amp 120 volt w neutral/ indoor
L211N specs Double pole 30 amp 120/240 volt w neutral

L211N Fusible
Larger image
Larger image2

Multimeter
Test for breaks in wire/ Test for voltage
Most appliance require 80% rated voltage to function correctly
Buy
Analog multimeter
Multimeters at Amazon
Klein multimeter
Electric testers at Amazon
Clampmeter for testing amp flow on line
Resource:
How to test and replace element
How to test thermocouple
Element tests for 120 volts
How to test wire

Safety when testing wires:
Never touch wet or previously flooded appliance.
Never stand on wet surface when working on electric.
Never stand on bare soil, put down dry boards.
Tape tester leads to wood sticks to keep hands away from power.
Use non-contact voltage tester before touching wires.
Never touch or lean into any made of metal.
Remove metal objects from pockets.
Do not use oxygen or fuel accelerants in same room as electrical repairs

Resource:
Basic house wiring

Non-contact voltage tester
Test for power without touching connectors
NEVER assume power is OFF

Buy:
Non-contact voltage tester Amazon
Electric testers at Amazon
Resource:
How to test electric power is off
GFCI receptacle120 volt 15 amp devices including GFCI, timers, switches, plugs, wifi controls etc can be installed on 15 or 20 amp breaker.

120 volt GFCI, outlet, receptacle that is rated 20 amp can be installed on 20 amp breaker only, but NOT on 15 amp breaker.  
Buy
15 amp GFCI
20 amp GFCI
Buy
Basic electric book
Home plumbing/ electrical codes
Basic electric book
Or learn about basic household electricity... use and search my site/
Resource
Safe electric wiring
Basic house wiring

Use outlet tester to check for correct wiring on any 120 volt straight-blade outlet.
Buy:
Klein testers
Outlet tester
Circuit breaker finder
Electric usage monitor
armored cable
Non metallic flexible cables must carry ground wire, but do not have hazard of short circuit causing injury from shock.

Armored steel cable can be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure.

All conduit ...metal, plastic ... flexible and rigid ... must be attached to structure, and attached to enclosures, boxes.
Movement, damage and deterioration are major cause of electrical failure.
Buy:
Non-metallic flexible conduit
Power whip
Armored cable
Southwire armored cable cutter
Pull boxes
Southwire armored cable cutter
Electrical tools must be insulated.
Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off.

Buy:
Electrician tools kits
KLEIN TOOLS
Tools kits
IRWIN tools
KNIPEX
Connect wire to screw terminal
Use only 600 volt solid copper wire.
Do not use stranded wire or extension cord.
Do not use solder anywhere on residential 120-240 volt wiring.
Attach electric installation to structure. Tighten screws very tight against wire.

Buy:
NEC books
Dewalt plumbing/ electrical codes
Basic electric book
National electric code guide/ illustrated

Resources:
How to twist wire
How to select and install twist-on wire connectors
Lever switchWeatherproof lever switch on outdoor lights
Safely operate outdoor toggle switch
Replaces outdoor cover
Install over top of ordinary switch
Works with single-pole, double-pole, 3PST, 3-way, 4-way switches etc
Use weatherproof box for outdoor
Can be used indoor or outdoor

Buy:
Best choice: Cantex lever switch
Outdoor lever switches at Amazon
Lever switches

Resource
Cantex-toggle-switch-covers.pdf
Cantex-PVC-junction-boxes.pdf

Terminals

Terminals

Buy:
Crimping tool kit
Blue for 16-14 wire
Yellow for 12-10 wire
Ratcheting Crimper

Resource:
How to install terminal
Push on wire connectors

Push-on wire connectors in place of twist-on connectors

Buy:
Push on wire connectors Amazon
Red 3P connector for 10-14 gauge wire
Lever connectors for stranded wire at Amazon

Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable.

Code
-Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15
Buy
End cutting nippers at Amazon

 


When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistances on wire and creates weak point.
Buy tools:
Wire strippers at Amazon
Linesman pliers
Pro linesman plier
Needle nose pliers
End cutting nippers at Amazon
6x6x4 pull box
6" Pull box
Junction boxes for conduit and wiring
Buy:
Bud industries 6x6x4 best value/ no KO
Raco 6x6x4 metal pull box
Wiegman 6x6x4 pull box
Hoffman 6x6x4 pull box
Adamax raintight enclosure
Raintight 6x6x4 box
Pull boxes
Buy:
Pull boxes
Polycarbonite boxes
Resource: Enclosures and boxes
Electricity leaves power plant Resource: Electricity:
The grid is defined by three parts: transmission, distribution and end user. The following links show how it works
Power plant to end user power pole
Power pole to residential breaker box
Power pole to commercial breaker box

How to wire residential electric
How to wire commercial 3-phase

Why you need ground wire
How to wire 3-phase timer
3-phase water heater

Contactors/ relays
Type 1 and type 2 surge protection surge protection
Programmable timers

Woods timers
surge protection
Buy
Electronic parts

Industrial supplies

Tools and home improvement

Home and garden

Hayward pool
Pentair pool

Southwire electric
Buy
Tools

DEWALT
Black and Decker
Stanley
SKIL
Makita
Porter-Cable
Bosch

Irwin Hand tools
Klein hand tools
Fluke electrical testing
Dremel hobby tools

Campbell Hausfeld air powered
Tekton automotive

Powerbuilt automotive
Saws and saw blades
box timers Resource:
Compare box timers
DPDT timers
Intermatic
Control water heater w/ Z-wave
Intermatic control centers Resource:
Intermatic control centers: and parts
Digital control centers and parts
Tork control centers and parts
Subpanels
All control centers and parts
Enclosures
programmable timer Resource:
Programmable timers
Countdown timers
Off delay timers
On delay timers
Timer modules
Din rail
Twin & one-shot
Woods
Intermatic
Tork
Low voltage power packs Recirculation systems

Buy from my affiliate links every time/ thanks:
Amazon
As an Amazon Associate I earn from qualifying purchases
Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission

E-mail: geno03245w@gmail.com
My response might end up in spam folder, check email folders
Waterheatertimer on Twitter
Message thru facebook