How to test if water heater electricity is off <> 3 methodsHow to test electricity between circuit breaker and water heater |
Multimeter Test for breaks in wire/ Test for voltage Most appliance require 80% rated voltage to function correctly Buy Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line Resource: How to test and replace element How to test thermocouple Element tests for 120 volts How to test wire |
Safety
when testing wires:
Never touch wet or previously flooded appliance. Never stand on wet surface when working on electric. Never stand on bare soil, put down dry boards. Tape tester leads to wood sticks to keep hands away from power. Use non-contact voltage tester before touching wires. Never touch or lean into any made of metal. Remove metal objects from pockets. Do not use oxygen or fuel accelerants in same room as electrical repairs Resource: Basic house wiring |
Non-contact voltage tester Test for power without touching connectors NEVER assume power is OFF Buy: Non-contact voltage tester Amazon Electric testers at Amazon Resource: How to test electric power is off |
120 volt 15 amp devices
including GFCI, timers, switches, plugs, wifi controls etc can be
installed on 15 or 20
amp
breaker. 120 volt GFCI, outlet, receptacle that is rated 20 amp can be installed on 20 amp breaker only, but NOT on 15 amp breaker. Buy 15 amp GFCI 20 amp GFCI |
Buy Basic electric book Home plumbing/ electrical codes Or learn about basic household electricity... use and search my site/ Resource Safe electric wiring Basic house wiring |
Use outlet tester to check for correct wiring on any 120 volt straight-blade outlet. Buy: Klein testers Outlet tester Circuit breaker finder Electric usage monitor |
Non metallic flexible cables must carry ground wire, but do not have hazard of short circuit causing injury from shock. Armored steel cable can be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure. All conduit ...metal, plastic ... flexible and rigid ... must be attached to structure, and attached to enclosures, boxes. Movement, damage and deterioration are major cause of electrical failure. Buy: Non-metallic flexible conduit Power whip Armored cable Southwire armored cable cutter Pull boxes |
Electrical tools must be insulated. Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off. Buy: Electrician tools kits KLEIN TOOLS Tools kits IRWIN tools KNIPEX |
Connect wire to screw terminal Use only 600 volt solid copper wire. Do not use stranded wire or extension cord. Do not use solder anywhere on residential 120-240 volt wiring. Attach electric installation to structure. Tighten screws very tight against wire. Buy: NEC books Dewalt plumbing/ electrical codes Basic electric book National electric code guide/ illustrated Resources: How to twist wire How to select and install twist-on wire connectors |
Weatherproof
lever switch on outdoor lights Safely operate outdoor toggle switch Replaces outdoor cover Install over top of ordinary switch Works with single-pole, double-pole, 3PST, 3-way, 4-way switches etc Use weatherproof box for outdoor Can be used indoor or outdoor Buy: Best choice: Cantex lever switch Outdoor lever switches at Amazon Lever switches Resource Cantex-toggle-switch-covers.pdf Cantex-PVC-junction-boxes.pdf |
TerminalsBuy:Terminal kit Blue for 16-14 wire Yellow for 12-10 wire Resource: How to install terminal |
Push-on wire connectors in place of twist-on connectorsBuy:Push on wire connectors Amazon Red 3P connector for 10-14 gauge wire Lever connectors for stranded wire at Amazon |
Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. Code -Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon |
When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistances on wire and creates weak point. Buy tools: Wire strippers at Amazon Linesman pliers Pro linesman plier Needle nose pliers End cutting nippers at Amazon |
Weather resistant plastic box for outdoor extension cord connections, Christmas lights, outdoor power strip etc . Not for connecting wires with wire nutsŪ, or in-wall wiring, but can be used indoors to organize extension cords, power strips etc. Weather resistant is not weatherproof or watertight. Use enclosures rated IP65 and IP67 for waterproof. Extension cords cannot be used for permanent wiring. Buy: Large-medium-small electric cord box Socketbox Raintight enclosures Water-tight cord lock Resource: Enclosures and boxes |
|
Never
assume power is OFF
Electrocution warning Do NOT touch wet water heater or water heater that was flooded. Put down dry boards. Do not touch metal objects. Method #1: use non contact voltage tester Use non-contact voltage tester on timer, on wire, on outlet to see if power is present. Press button on tester, if single beep then no power is present. If continuous beep then power is present. Never stand on bare ground, always stand on dry boards, do not hold or touch anything metal when working on timer or water heater that has power, tape tester leads to wood sticks, never touch wet water heater, or flooded water heater, or timer that had a short or fire without turning power OFF. |
Larger image Use ordinary tester or multimeter 1. Test black wire to ground screw > and then 2. Test black wire to white wire > and then 3. Test white wire to ground screw >> if no power shows with these 3 tests, then electricity is off tester and green ground screw |
Method
#2:
Test where wire arrives at water heater
> Turn off electricity at circuit breaker box > 120 Volt water heater will have 20Amp breaker > 240 Volt water heater will have 30 Amp breaker > Read information on side of tank to see appliance voltage [or read owner's manual] > Electricity arrives at water heater in wire coming from circuit breaker box > Wire is held to water heater with a clamp > leave clamp alone > Look for metal plate (next to wire) > under metal plate are wiring connections > Remove screw or screws so the metal plate comes loose > Inside there are 3 sets of wires: > a bare copper usually attached to green ground screw > 2 white wires covered by wire nut > 2 black wires covered by a wire nut > 240 Volt or 120 Volt there will be 3 wires review basic circuit > The white and black wires are covered with wire nuts > Leave bare copper wire attached to water heater > Remove wire nuts that cover black & white wires (while doing this, do not touch any bare wire, do not touch metal water heater, do not lean against water heater, do not touch metal pipes or metal ductwork, always wear dry clothes and dry shoes and never stand on bare soil or damp floor, put down dry boards or plywood) > So now, the wire nuts are off black & white wires > Test black wire to bare copper wire > if light shows on tester, then electricity is present > solve problem: try turning off another breaker > Must double-check result > test black wire to white wire -and- finally test white wire to ground If no light shows with these 3 tests, then electricity is off. |
See larger Example of upper thermostat |
Method
#3 for checking water heater: Test upper thermostat
> Read label on side of tank to see appliance voltage 120V or 240V [or read owner's manual] > Remove cover from side of water heater to reveal thermostat see image > Thermostat is 1-1/2" wide x 4" tall and has red reset button > Use flashlight and look closely at markings on thermostat > Topmost 2 screws are labeled L1 and L3 -or- they are labeled 1 and 3 > Test across L1 to L3 > test light will come on if electricity is present see diagram Resources: See troubleshooting steps for electric water heater How to test electricity from circuit breaker to water heater |
Use only 600 volt wire. Lamp cord, extension cords are not rated 600 volt. Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional. 30 amp breaker use 10 gauge / 120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker. Orange/ #10 gauge wire, with ground ... 30 amp capacity. Safe maximum: 30 x 80% = 24 amps. Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp Southwire electric tools |
Yellow
12 gauge 20 amp 120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire. ... cannot be connected to 30-40 amp breaker. 1 Yellow/ #12 gauge wire, with ground ... 20 amp capacity. Safe maximum 16 amps. Buy: 12-2 gauge/ 20 amp 12-3/ 20 amp NMB is house wiring UF is underground Rolls of stranded wire HOOK UP Wires |
White
14 gauge 15 amp 120 volt 15 amp outlet, AFCI, GFCI, timer, switch etc can be installed on 15 or 20 amp breaker. Never connect 15 gauge wire to 20-30-40 amp breaker. White/ #14 gauge wire, with ground ... 15 amp capacity. Safe maximum 12 amps. Buy: 14-2 gauge/ 15 amp 14-3/ 15 amp NMB is house wiring UF is underground |
50-60
amp breaker use 6 gauge / 240 volt 50 outlet can be installed on 50 amp breaker only Buy: 6-2 wire Southwire electric tools NMB is house wiring UF is underground |
40-50
amp breaker use 8 gauge / 240 volt 40 amp outlet can be installed on 40 or 50 amp breaker only Buy: 8-2 wire Southwire electric tools NMB is house wiring UF is underground |
Copper ground wire. Every device, load, metal enclosure etc must be grounded. Ground wire must be continuous throughout installation, never switched on-off, never used as a Neutral wire. Generally ... use same size as other wire in circuit Buy: 12 gauge copper ground wire Ground wire Green ground wire Ground pigtails Ground rods/ ground clamps at Amazon |
Non metallic flexible cables must carry ground wire, but do not have hazard of short circuit causing injury from shock. Armored steel cable can be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure. All conduit ...metal, plastic ... flexible and rigid ... must be attached to structure, and attached to enclosures, boxes. Movement, damage and deterioration are major cause of electrical failure. Buy: Non-metallic flexible conduit Power whip Armored cable Southwire armored cable cutter Pull boxes |
Electrical tools must be insulated. Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off. Buy: Electrician tools kits KLEIN TOOLS Tools kits IRWIN tools KNIPEX Telephone cable knife Low Voltage Mounting Bracket for Telephone |
Push-on wire connectors in place of twist-on connectorsBuy:Push on wire connectors Amazon Red 3P connector for 10-14 gauge wire Lever connectors for stranded wire at Amazon HOOK UP Wires |
Protect wiring from damage Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. -Code says: Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon |
Electrically insulated tools When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistance and heat on wire and creates possible weak point. Buy tools: KLEIN TOOLS Wire strippers at Amazon Electric Wire Stripping Machine Linesman pliers Utility knife at Amazon |
Multimeters Voltage is tested across two separate wires. Ohms or resistance is tested across both ends of same wire. Amperage is tested along one or two points on same wire. Buy: Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line |
GFCI circuit breaker A GFCI circuit breaker will protect all boxes on circuit. Circuit must be grounded. Ground wire must be continuous and connected to each piece of equipment. White wire on circuit breaker must be connected to Neutral busbar inside the breaker panel. Buy GFCI circuit breakers |
Push down 1" wide Push down breaker Plug-in breaker Buy single-pole: Choose from 15 to 60 amp Eaton CL series Siemens 15-60 amp Single-pole tandem breaker Tandem breakers |
Push down 2" wide Push down breaker Plug-in breakers Buy double-pole: Choose from 15 to 125 amp Choose from 15 amp to 200 amp Eaton CL series circuit breaker Siemens circuit breaker Double pole GFCI |
Meter on water heater The Kwh meter is din rail mounted inside enclosure. Records billable power usage in Kwh. Multiply by rate you pay per Kwh to get monthly/ yearly cost of running electric water heater. Buy Bomain power meter Ketotek power meter 240 volt pass through Kwh meter 2T2502GA beige plastic enclosure 2T2500GA grey plastic enclosure din rails Resource: Enclosures Figure volts amp watts for water heater |
|
Circuit
breaker resources Water heater is tripping breaker How to replace circuit breaker How to wire gfci Can AC breaker be used for DC breaker How to reset circuit breaker Not enough space for circuit breakers/ use tandem Circuit breakers How to install subpanel Why you need ground wire See inside breaker box How to wire safety switch How to wire whole house surge protector Figure volts amps and watts Figure correct wire and breaker Types of surge protection How to test electricity from circuit breaker to water heater How to replace circuit breaker |
Buy Industrial electric Industrial supplies Tools and home improvement Home and garden Hayward pool Pentair pool Southwire electric |
|
Buy
Tools DEWALT Black and Decker Stanley SKIL Makita Porter-Cable Bosch Irwin Hand tools Klein hand tools Fluke electrical testing Dremel hobby tools Campbell Hausfeld air powered Tekton automotive Powerbuilt automotive Saws and saw blades |
|
Resource: Compare box timers DPDT timers Intermatic Control water heater w/ Z-wave |
|
Resource: Intermatic control centers: and parts Digital control centers and parts Tork control centers and parts Subpanels All control centers and parts Enclosures |
|
Resource: Programmable timers Countdown timers Off delay timers On delay timers Timer modules Din rail Twin & one-shot Woods Intermatic Tork |
|
Recirculation systems |
Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |