Delay timer for motor or pump/ 120Volt to 240Volt
Resource: safe electric wiring

Multimeter
Test for breaks in wire/ Test for voltage
Most appliance require 80% rated voltage to function correctly
Buy
Analog multimeter
Multimeters at Amazon
Klein multimeter
Electric testers at Amazon
Clampmeter for testing amp flow on line
Resource:
How to test and replace element
How to test thermocouple
Element tests for 120 volts
How to test wire
Safety when testing wires:
Never touch wet or previously flooded appliance.
Never stand on wet surface when working on electric.
Never stand on bare soil, put down dry boards.
Tape tester leads to wood sticks to keep hands away from power.
Use non-contact voltage tester before touching wires.
Never touch or lean into any made of metal.
Remove metal objects from pockets.
Do not use oxygen or fuel accelerants in same room as electrical repairs

Resource:
Basic house wiring

Non-contact voltage tester
Test for power without touching connectors
NEVER assume power is OFF

Buy:
Non-contact voltage tester Amazon
Electric testers at Amazon
Resource:
How to test electric power is off
GFCI receptacle120 volt 15 amp devices including GFCI, timers, switches, plugs, wifi controls etc can be installed on 15 or 20 amp breaker.

120 volt GFCI, outlet, receptacle that is rated 20 amp can be installed on 20 amp breaker only, but NOT on 15 amp breaker.  
Buy
15 amp GFCI
20 amp GFCI
Buy
Basic electric book
Home plumbing/ electrical codes
Basic electric book
Or learn about basic household electricity... use and search my site/
Resource
Safe electric wiring
Basic house wiring

Use outlet tester to check for correct wiring on any 120 volt straight-blade outlet.
Buy:
Klein testers
Outlet tester
Circuit breaker finder
Electric usage monitor
wire connector assortment

Twist-on wire connector assortments

Do not reuse old connectors
Twist wire connector very tight. Pull wires to ensure they will not come loose. Cover all bare copper.
Buy:
Connector assortment at Amazon
Connector assortment at Amazon
Resource
How to select and install twist-on wire connectors
Southwire armored cable cutter
Electrical tools must be insulated.
Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off.

Buy:
Electrician tools kits
Klein tools
Tools kits
Connect wire to screw terminal
Use only 600 volt solid copper wire.
Do not use stranded wire or extension cord.
Do not use solder anywhere on residential 120-240 volt wiring.
Attach electric installation to structure. Tighten screws very tight against wire.

Buy:
NEC books
Dewalt plumbing/ electrical codes
Basic electric book
National electric code guide/ illustrated

Resources:
How to twist wire
How to select and install twist-on wire connectors
Lever switchWeatherproof lever switch on outdoor lights
Safely operate outdoor toggle switch
Replaces outdoor cover
Install over top of ordinary switch
Works with single-pole, double-pole, 3PST, 3-way, 4-way switches etc
Use weatherproof box for outdoor
Can be used indoor or outdoor

Buy:
Best choice: Cantex lever switch
Outdoor lever switches at Amazon
Lever switches

Resource
Cantex-toggle-switch-covers.pdf
Cantex-PVC-junction-boxes.pdf

Treminals

Terminals

Buy:
Terminal kit
Blue for 16-14 wire
Yellow for 12-10 wire

Resource:
How to install terminal
Push on wire connectors

Push-on wire connectors in place of twist-on connectors

Buy:
Push on wire connectors Amazon
Red 3P connector for 10-14 gauge wire
Lever connectors for stranded wire at Amazon
remove cable staple
Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable.

Code
-Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15
Buy
End cutting nippers at Amazon

 
linesman pliers

When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistances on wire and creates weak point.
Buy tools:
Wire strippers at Amazon
Linesman pliers
Pro linesman plier
Needle nose pliers
End cutting nippers at Amazon

Weather resistant plastic box for outdoor extension cord connections, Christmas lights, outdoor power strip etc . Not for connecting wires with wire nutsŪ, or in-wall wiring, but can be used indoors to organize extension cords, power strips etc.
Weather resistant is not weatherproof or watertight. Use enclosures rated IP65 and IP67 for waterproof.
Extension cords cannot be used for permanent wiring.
Buy:
Large-medium-small electric cord box
Socketbox
Raintight enclosures
Water-tight cord lock
Resource: Enclosures and boxes
Motor delay timer
For 120-240V cut blue jumper wire located on front of timer between terminals
Adjustments less than 30 seconds might not be possible
2" x 2" size
Start motor or pump with delay 1.8 second to 10 minute
Delay on make:
Time delay begins when power is applied to input. After delay, load turns ON and stays ON until power is turned OFF.

Buy 120-240 Volt delay ON:
ICM 102 / 18-240VAC 1.5 amp load Amazon
Packard 102

Buy: contactors:
Packard contactor with 24Volt coil
120Volt coil
240Volt coil

Resource:
ICM 102 delay ON timer manual .pdf
More contactors
Terminals
Fuseholders
Enclosures
2 motor delay timer
For 120-240V cut blue jumper wire located on front of timer between terminals
Adjustments less than 30 seconds might not be possible
Turn on 2nd motor after another motor starts
Delay on make:
Turn on pump after another pump starts
Turn on 1 motor before another motor
120Volt or 240Volt

In-line fuse protects on-delay timer

Load 1 Turns ON when switch or timer turns ON.
Load 2 turns ON after delay

Reason for this system might be to reduct initial load on circuit so motors do not pull starting amps at same time.
Another reason is that one pump feeds water to second pump. Second pump should not start until water arrives from first pump.
Elko delay timer Elko delay timer/ Multifunction
Delay on make: On-delay, Load turns ON and stays ON after delay period.
Other applications for timer .. wiring not illustrated here: Off-delay, repeat cycle, delay on break, pulse generator, latching, single shot.
Input voltage 12V - 240 volt (50-60 Hz)
Indicator lights
.1 seconds to 10 days

Buy:
Elko delay timer
Migro delay timer
Migro relays and timers

Resources:
CRM-93H   10-function
CRM-91H  10 function
CRM-82 two-function
AH3 24 volt
10 amp LY2 relays
LY3 relay
120 volt LY2
120 volt MY2
AH3 24 volt 60 second
AH3 24 volt 10 minute
Baomain delay timers
Baomain relay
AH3 off delay timer
ST01 delay timer
ON Delay
Delay on make: Illustration shows ON delay wiring for 120 V.
On delay means the load turns ON after delay period expires. Load remains ON until power is off.
Example uses ST01 timer as switch. (Or use Ei600... same timer except 5-year warranty)

ST01 Timer can be set for dusk-dawn. Automatically turns lights ON at night, and off at dusk.
ST01 Timer automatically adjusts for seasonal changes.
ST01 Timer can be adjusted 20 minutes longer or shorter than actual dusk-dawn

However some folks want longer delay before lights turn ON at night
How it works:
ST01 Timer turns ON. AH3 timer receives power. Time delay countdown begins.
After delay period expires, light turns ON, and remains ON until ST01 timer turns OFF
Cycle repeats next time the ST01 timer turns ON.
Buy:
AH3 timers
Intermatic ST01 timer
Ei600 timer
CR2 replacement battery

Resources:
More wiring diagrams/ How to wire AH3
Twin timer

One-shot timer

Precise digital control
Set mode for one-shot
For on delay: Apply power to terminals 9-10, and normally closed terminal 6 remains OFF until time expires. and then terminal 6 turns ON until power is cut.
For off delay: Apply power, and normally open terminals turn ON for set time, and then remain off until power is cut and applied again.
This can be operated with a Normally closed push button that applies continuous power to the timer mechanism. When the push button is pushed, it starts the delay time circuit for the set duration of time.
Time durations: .01 seconds to 99hour99 minutes (4.16 days)
Repeasts each time power is applied again.

1/2 Hp @ 120 Volt
3/4 Hp @ 240 V
100-240 volt AC/DC input terminals are separate from output terminals
Buy:
B3S one-shot timer
Resource
B3S timer manual
Options for Motor driven countdown timer
override air conditioner with timerReduce run-time of motor or air conditioner.
Problem: air conditioner runs too much during peak electric prices. Programmable thermostat for the air conditioner can control peak usage by raising temperature and reducing hours of operation during peak times, but it cannot be programmed to limit actual number of run-time minutes per hour.

This diagram solves problem without compromising integrity of AC motor or equipment.

The din rail timer is programmed so timer is ON during peak hours. Any programmable timer will do the job but din rail timers are available in both 120 and 240 volt models. And 12-24 volt also.

When the din rail  timer is ON, it turns ON a relay, and turns ON a twin timer.
When the din rail timer is OFF, the relay is OFF and the twin timer is OFF.

One of the 24 volt wires from thermostat is connected to the com terminal on one side of relay. When the din rail timer is OFF, the relay is OFF, and the 24 volt thermostat circuit is routed straight to the contactor for normal operation of air conditioner.

When the din rail timer is ON, the relay is ON, and it switches the 24 volt thermostat wire away from contactor and to the Twin timer.
The twin timer is rated for either 120 or 240 volt. Twin timer is designed to turn on-off-on-off-on-off in endless repeat cycle. ON times and OFF times are set independently, and can be any value between .01 second and 99.99 hours.
For example, the twin timer ON time can be set for 40 minutes. And OFF time set for 20 minutes. This limits the operation of air conditioner to 40 minutes.
During the 40 minute period, the twin time routes 24 volts to the air conditioner contactor for normal operation.

After 40 minutes, the twin timer cycles OFF, and then air conditioner cannot turn on for 20 minutes until the twin timer cycles back ON again. When the 20 minutes expires, the twin timer again lets the 24 volts complete circuit to contactor for 40 minutes.
The cycle of 40 ON and 20 OFF continues as long as din rail timer is ON. Set the din rail timer to turn ON during peak electric prices.

Illustration on right shows same diagram except pulling power off the 240 volt AC circuit. Use 10-15 amp inline fuse to protect timer and relay circuit from 50-60 amp air conditioner circuit. Use terminals to connect the smaller wires to contactor. Prevent loose connection and risk of fire: Do not put two different gauge wires under the screw plate on contactor. Never put stranded wire under screw plate.

Buy:
120-240 volt THC15 din rail timer

120 volt LY2 relay
240 volt relay

120-240 volt Twin timer

HVAC contactors
Inline fuse holders
Din rail fuse holder

Resources:
How to wire twin timer
Din rail timers and  manuals
Relays and contactors
Use in-line fuse when connecting 2 different gauge wires
Illustration shows smaller 12-2 cable connected to larger 10-3 cable.

The 10 gauge wire carries 240 volt plus a Neutral wire, and is protected by 30 amp breaker
The amp draw on 30 amp breaker is too large for 12 gauge wire.
12 gauge wire should have 20 amp breaker.
Connect smaller 12 gauge wire to 10 gauge wire using twist on wire connector. All connections must be inside electrically rated enclosed box with cover.
Use fuseholder with 20 amp fuse.
Fuse will protect entire length of 12 gauge wire.
Connect fuse to Hot wire.
Never put fuse on Neutral ... the Neutral wire must never be switched off, and must run continuous throughout installation.

If the 12 gauge wire is wired for 240V, instead of 120V shown in illustration, then fuses can be added to both hot wires.
Always make connections inside a box with cover
Buy:
Panel mount fuse holders at Amazon
ANL fuseholder
Buy fuseholders
Din rail fuseholder
10 x 38 mm fuse
Electrical terminals
Solder guns

Resource:
Fuseholders
WeMo switch wiring
Larger image
How to wire WeMo switch
WeMo allows programming via smart phone
Do not use stranded wire under screw plates
Buy from my affiliate links:
WeMo switch
Contactor with 120 volt coil
6x6x4 Box to install contactor

Resources:
WeMo switch and module wiring
Illustrations of contactor wiring
Select correct wire and breaker size
Contactors
WeMo switch wiring
Skylink remote control countdown timer
Skylink wireless countdown
Skylink wireless programmable or countdown
Countdown is same as off-delay: load turns ON immediately and turns OFF after delay period ends.
Estimate 1/3 Hp
Grundfos pump is 1/25 Hp
120V 60 Hz/ 10 watt minimum/ 1500 watt
Operate as ON-OFF or Countdown device/ Up to 500 feet
15 minute - 60 minute countdown
Buy:
Wireless wall mount transmitter TB-318
Wireless countdown receiver PA-318
Transmitter and receiver
Resource:
PA-318 manual
off-delay timer for recirculation systemLarger image
Load
Max load on off-delay timer is 10 amp.
Suggest using contactor to preserve life of timer

How it works:
Push doorbell button. Activates timer. Timer turns ON and begins countdown. Timer terminals 7 and 8 are ON. This causes contactor coil to energize. Circuit to recirculation pump is ON.
When countdown expires, terminals 7 and 8 are OFF, contactor coil is de-energized, pump turns OFF.
Twin timer can be set to one-shot mode, and with 120-240V, and operate .9 seconds to 99 hours. So the pump can run any length of time: 1 hour or 21 minutes etc.
Do not connect power to terminals 1-5.
How to wire twin timer

Buy: Project materials:
Twin timers at Amazon
Sestos twin timer
Omron DH48S twin timer
Example 50' thermostat wire at Amazon

Contactor with 120Volt coil At Amazon
                 More contactor illustrations

                 More off delay and pin timer illustrations

Normally open Push button

ST01C timer controls 120Volt delay-off-timer
Activate off-delay timer using push button -or- using ST10 timer
Push button, or ST01, activates delay timer.
Push button gives momentary on-off to activate delay timer
When ST01 turns ON and then OFF, then delay timer activates
Delay timer turns Load ON
Delay timer begins countdown.
When countdown expires, delay timer turns Load Off
Buy from my affiliate links:
6A855 Solid State timer
11-pin plug-in base
Contactor with 120volt coil
ST01 battery-operated timer
Resource:
6A855 Manual
More off-delay timers
off-delay timer for recirculation system Operate recirculation system remotely from 1-2-3+ different locations
How it works:
Do NOT connect voltage to bell wire going to push buttons
Buy delay timer and base
Connect 120volt Hot and Neutral wires to base as illustrated.
Buy thermostat or bell wire and connect to push buttons as shown
The push buttons receive no voltage or power... do not connect to power source.
Plug timer into base. Choose delay time from .05 seconds to 999 seconds
Push doorbell button. Activates timer.
Timer turns ON and begins countdown.
Pump turns ON and runs until countdown stops. Countdown is off-delay.
When countdown expires, timer turns OFF, pump turns OFF.
Delay timer rated 1/3 Hp.... recirculation pump rated 1/25 Hp

Buy project materials:
Example 50' thermostat bell wire
6A855 Solid State timer
11-pin plug-in base
Push button plate Amazon
Resources
Other countdown timers
More off delay and pin timer illustrations
6A855 Manual
remote control countdown timer
Larger image
Remote control countdown timer
Buy:
6A855 Solid State timer
11-pin plug-in base
General purpose relay
Woods 32555
GE
Wireless remote controls
Replacement A23 battery

Select recirculation pump
Resources:
See analog plug-in timers
See remote controls
Water heater recirculation system
Control motor with 2 switches
Larger image
Larger image 2
Control motor with 2 switches
Same wiring diagram applies to single-pole switch
Contactor with 240Volt coil

Buy:
240Volt coil

Start winding pulls more amps than switch can safely handle.
Over time, the switch will fail.
Contactors are rated for heavy amp loads, with expected life of millions of operations
Wire contactor use miniature relay instead of contactor. The wiring is not illustrated, so let me know if you want specific illustration.
Resource:
Zetter-relay-wiring.jpg

Buy: contactors:
Packard contactor with 24Volt coil
120Volt coil
240Volt coil
      Terminal kit     Terminals:
Crimp terminals onto stranded wire
Solder terminals onto solid wire
Buy:
Terminal kit
Blue terminals for 16-14 gauge wire
Yellow 12-10 gauge female terminal 16 pcs

6X6X4 Metal box w/ Contactor

carlton 6x6x4 junction box
6x6x4 Plastic box
Buy 6x6x4 junction box
Plastic box and metal boxes
Available home center/ electric supply house/ or online

Buy:
6x6x4 plastic box: no pre-drilled holes... must drill holes for Wire connections, 1/2" hole for fuseholder, 3/16" holes for bolts to hold contactor, plastic box does not need ground screw connected to box
Cantex 6x6x4 PVC plastic enclosure with cover
Thomas and Betts 6x6x4 plastic with cover
Bud industries 11x7x5 box without knockouts
Buy:
6x6x4 Metal box: has knock-outs for 1/2 and 3/4" ... must drill 1/2" hole for fuseholder, bolt holes to hold contactor, threaded holes for 10-32 ground screw, metal box must be grounded.
Raco 6x6x4 metal pull box with cover and knock-outs
Raco 6x6x4 metal pull box with cover and knock-outs
RACO outdoor 6x6x4 box with bottom knockouts
Wiegmann 67x6x4 pull box with knockouts on 4 sides
Hoffman 6x6xx4 pull box with knockouts on 4 sides
Buy
6x8x4 metal box
Bud industries 6x8x4 box with hinged door
Bud industries boxes
Resource:
See more about boxes
fuseholderBusman fuse holder Buy inline fuseholder and ceramic fuse to protect timer from overload
Buy:
Panel mount fuse holders
ANL fuseholder
Buy fuseholders
Ceramic fuses
Din rail fuseholder
10 x 38 mm fuse

Resource:
Read about fuseholders
Use only 600 volt wire.
Lamp cord, extension cords are not rated 600 volt.
Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional.

30 amp breaker use 10 gauge /
120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker.

Orange/ #10 gauge wire, with ground ... 30 amp capacity. Safe maximum: 30 x 80% = 24 amps.
Buy:
10-2 gauge/ 30 amp
10-3/ 30 amp
Southwire electric tools
Yellow 12 gauge 20 amp
120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire.
... cannot be connected to 30-40 amp breaker.

Yellow/ #12 gauge wire, with ground ... 20 amp capacity. Safe maximum 16 amps.
Buy:
12-2 gauge/ 20 amp
12-3/ 20 amp

NMB is house wiring
UF is underground
Rolls of stranded wire
White 14 gauge 15 amp
120 volt 15 amp outlet, AFCI, GFCI, timer, switch etc can be installed on 15 or 20 amp breaker. Never connect 15 gauge wire to 20-30-40 amp breaker.

White/ #14 gauge wire,  with ground ... 15 amp capacity. Safe maximum 12 amps.
Buy:
14-2 gauge/ 15 amp
14-3/ 15 amp

NMB is house wiring
UF is underground
50-60 amp breaker use 6 gauge /
240 volt 50 outlet can be installed on 50 amp breaker only
6-2 wire
Buy:
6-2 wire
Southwire electric tools
NMB is house wiring
UF is underground
40-50 amp breaker use 8 gauge /
240 volt 40 amp outlet can be installed on 40 or 50 amp breaker only
6-2 wire
Buy:
8-2 wire
Southwire electric tools
NMB is house wiring
UF is underground
    
Copper ground wire.
Every device, load, metal enclosure etc must be grounded. Ground wire must be continuous throughout installation, never switched on-off, never used as a Neutral wire.
Generally ... use same size as other wire in circuit
Buy:
12 gauge copper ground wire
Ground wire
Green ground wire
Ground pigtails
Ground rods/ ground clamps at Amazon
armored cable
Armored cable can be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure.

Non metallic flexible cables must carry ground wire, but does not have hazard of short circuit causing injury from shock.

All conduit ...metal, plastic ... flexible and rigid ... must be attached to structure, and attached to enclosures, boxes.
Movement, damage and deterioration are major cause of electrical failure.
Buy:
Armored cable
Southwire armored cable cutter
Non-metallic flexible conduit
Power whip
Pull boxes
Southwire armored cable cutter
Electrical tools must be insulated.
Always best to disconnect power, but issues of insulation failure, lack of proper grounding, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems pose a risk to anyone working on electric power.

Buy:
Electrician tools kits
Klein tools
Tools kits
stranded wire
12 ga Stranded wire is good for conduit with multiple wires ... but stranded cannot be installed under screw terminals on outlets, switches, timers etc without risk ... of heat causing splayed strands ....that come loose ... and begin to arc. Connect stranded to short piece of solid copper wire, and attach solid to screw terminal. Do not solder residential or commercial wiring.
Buy:
Rolls of stranded wire

Protect wiring from damage
Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable.

-Code says: Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15
Buy
End cutting nippers at Amazon


Electrically insulated tools
When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistances and heat on wire and creates possible weak point.
Buy tools:
Wire strippers at Amazon
Linesman pliers
Utility knife at Amazon
multimeter
Multimeters
Voltage is tested across two separate wires. Ohms or resistance is tested across both ends of same wire. Amperage is tested along one or two points on same wire.
Buy:
Analog multimeter
Multimeters at Amazon
Klein multimeter
Electric testers at Amazon
Clampmeter for testing amp flow on line
Support the economy:
Buy water heaters from my associate links:

50 gallon Gas water heaters at Amazon
40 gallon gas water heaters at Amazon
50 gallon Electric water heaters at Amazon
40 gallon electric water heaters at Amazon
Hybrid / heat pump/ water heaters at Amazon

Resources:
How to install gas water heater
How to install electric water heater
Troubleshoot gas water heater
Troubleshoot electric water heater
Point of use water heaters
Resources:
Troubleshoot Gas valves with manuals
Icon gas valve

How to replace water heater element Waste King disposal
How to wire tankless electric


Install point of use water heater
Titan tankless

Contactors/ relays
Install and troubleshoot garbage disposal Waste King disposal
Programmable timers

Woods timers
surge protection
Anode rods anode rods
Recirculation system

Tankless recirculation
Point of use water heater
Type 1 and type 2 surge protection surge protection
Buy
Industrial electric

Industrial supplies

Tools and home improvement

Home and garden

Hayward pool
Pentair pool

Southwire electric
Buy
Tools

DEWALT
Black and Decker
Stanley
SKIL
Makita
Porter-Cable
Bosch

Irwin Hand tools
Klein hand tools
Fluke electrical testing
Dremel hobby tools

Campbell Hausfeld air powered
Tekton automotive

Powerbuilt automotive
Saws and saw blades
box timers Resource:
Compare box timers
DPDT timers
Intermatic
Control water heater w/ Z-wave
Intermatic control centers Resource:
Intermatic control centers: and parts
Digital control centers and parts
Tork control centers and parts
Subpanels
All control centers and parts
Enclosures
programmable timer Resource:
Programmable timers
Countdown timers
Off delay timers
On delay timers
Timer modules
Din rail
Twin & one-shot
Woods
Intermatic
Tork
Low voltage power packs Recirculation systems
Enter Amazon from my links
Amazon

E-mail: geno03245w@gmail.com
My response might end up in spam folder, check email folders