How
to wire TB118 TB178 timer
How to wire TB17 DTD-1400 etc timers TB 178 timer manual |
Use only 600 volt wire. Lamp cord, extension cords are not rated 600 volt. Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional. 30 amp breaker use 10 gauge / 120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker. Orange/ #10 gauge wire, with ground ... 30 amp capacity. Safe maximum: 30 x 80% = 24 amps. Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp Southwire electric tools |
Yellow
12 gauge 20 amp 120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire. ... cannot be connected to 30-40 amp breaker. 1 Yellow/ #12 gauge wire, with ground ... 20 amp capacity. Safe maximum 16 amps. Buy: 12-2 gauge/ 20 amp 12-3/ 20 amp NMB is house wiring UF is underground Rolls of stranded wire HOOK UP Wires |
White
14 gauge 15 amp 120 volt 15 amp outlet, AFCI, GFCI, timer, switch etc can be installed on 15 or 20 amp breaker. Never connect 15 gauge wire to 20-30-40 amp breaker. White/ #14 gauge wire, with ground ... 15 amp capacity. Safe maximum 12 amps. Buy: 14-2 gauge/ 15 amp 14-3/ 15 amp NMB is house wiring UF is underground |
50-60
amp breaker use 6 gauge / 240 volt 50 outlet can be installed on 50 amp breaker only Buy: 6-2 wire Southwire electric tools NMB is house wiring UF is underground |
40-50
amp breaker use 8 gauge / 240 volt 40 amp outlet can be installed on 40 or 50 amp breaker only Buy: 8-2 wire Southwire electric tools NMB is house wiring UF is underground |
Copper ground wire. Every device, load, metal enclosure etc must be grounded. Ground wire must be continuous throughout installation, never switched on-off, never used as a Neutral wire. Generally ... use same size as other wire in circuit Buy: 12 gauge copper ground wire Ground wire Green ground wire Ground pigtails Ground rods/ ground clamps at Amazon |
Non metallic flexible cables must carry ground wire, but do not have hazard of short circuit causing injury from shock. Armored steel cable can be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure. All conduit ...metal, plastic ... flexible and rigid ... must be attached to structure, and attached to enclosures, boxes. Movement, damage and deterioration are major cause of electrical failure. Buy: Non-metallic flexible conduit Power whip Armored cable Southwire armored cable cutter Pull boxes |
Electrical tools must be insulated. Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off. Buy: Electrician tools kits KLEIN TOOLS Tools kits IRWIN tools KNIPEX Telephone cable knife Low Voltage Mounting Bracket for Telephone |
Push-on wire connectors in place of twist-on connectorsBuy:Push on wire connectors Amazon Red 3P connector for 10-14 gauge wire Lever connectors for stranded wire at Amazon HOOK UP Wires |
Protect wiring from damage Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. -Code says: Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon |
Electrically insulated tools When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistance and heat on wire and creates possible weak point. Buy tools: KLEIN TOOLS Wire strippers at Amazon Electric Wire Stripping Machine Linesman pliers Utility knife at Amazon |
Multimeters Voltage is tested across two separate wires. Ohms or resistance is tested across both ends of same wire. Amperage is tested along one or two points on same wire. Buy: Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line |
GFCI circuit breaker A GFCI circuit breaker will protect all boxes on circuit. Circuit must be grounded. Ground wire must be continuous and connected to each piece of equipment. White wire on circuit breaker must be connected to Neutral busbar inside the breaker panel. Buy GFCI circuit breakers |
Push down 1" wide Push down breaker Plug-in breaker Buy single-pole: Choose from 15 to 60 amp Eaton CL series Siemens 15-60 amp Single-pole tandem breaker Tandem breakers |
Push down 2" wide Push down breaker Plug-in breakers Buy double-pole: Choose from 15 to 125 amp Choose from 15 amp to 200 amp Eaton CL series circuit breaker Siemens circuit breaker Double pole GFCI |
Larger image |
TB17
timer DTD 1400 timer 220-240 Volt AC 15 Amp x 220 Volts = 3300 watts Motor load 220Volt 1500 watt= max 1/3 Hp motor Select 50 or 60 Hz to match local power worldwide Wires identical to TB178 timer Override knob located upper right corner. Timer resumes regular schedule at next tripper To override permanently, remove trippers Resource How to set timers Install trippers on dial. 30 minute on-off minimum. Manually rotate dial two times to see how load turns on-off. Set trippers at selected on-off times Rotate dial until current time lines up with white arrowhead located on inner dial. Timer dial rotates as time passes. Tripper pushes on-off lever. If dial does not rotate, then check incoming voltage, replace timer with new timer. |
TB178 Timer
TB118 Timer Input 100-240Volt AC Mim 88 volts AC Max 264 volts AC 50-60 Hz for worldwide application |
|
For
heavy duty switching,
connect timer to contactor. Over 1/3 Hp, install contactor Add busman fuses to lines between power source and timer. Fuse will protect timer from overload and possible fire hazard. Select contactor with coil voltage to match line voltage Resources Contactors Fuseholder Wire and breaker chart How to wire 240Volt outlets and plugs |
|
Legrand 649-915 4QT timer 20 amp 230Volt 50-60 cycle means timer works worldwide electric grid Identical wiring shown above Resource How to set analog timers Small segments located around dial Move a few segments, and then rotate dial to watch how lights turn on-off Set switch to ON for timer to operate on schedule Set current time: rotate dial until correct time shows on clock face, or until current time lines up with pointer marked current time. Resource More timers and manuals |
|
Wiring shows load connected to NO terminal, or Normally Open Terminal 4 is NC > or Normally Closed > this terminal has power when terminal 5 is OFF When terminal 5 is ON, then terminal 4 is OFF |
Intermatic
FM1 timer Quartz models rated 50-60 Hz Different model numbers for 24V, 120V, 240V, 21 amp Dry terminals mean other voltages can be controlled 24 Hour with 15 minute intervals 7-day with 2 hour intervals Override offers permanent ON, or permanent OFF 24-hour and 7-day models Buy: Intermatic FM1 timers at Amazon Grasslin timers at Intermatic 24-hour 120Volt 60 Hz at Amazon 7-day 120volt 60 Hz at Amazon 24-Hour 240Volt 60 Hz at Amazon 7-day 240Volt 60 Hz at Amazon Resources FM1 Model numbers FM1 series manual + model numbers Newest FM1 sell sheet How to set analog timers How to wire under counter water heater using FM1 |
In-line
fuse Add 15 amp busman line fuse to black wire going to photo eye to protect device if amp load of motor exceeds photo eye maximum load rating. See illustration Buy: Panel mount fuse holders at Amazon ANL fuseholder Buy fuseholders at Amazon Fuse blocks at Amazon Electrical terminals Din rail fuseholder 10 x 38 mm fuse Solder guns Buy fast and slow acting fuses: Ceramic fuses at Amazon Resource How to make terminal connections Yellow terminals for 12 gauge wire; Blue terminals for 14 gauge wire |
|
|
Yellow
female terminal for 10-12 gauge wire Blue female terminal for 14-16 gauge Available hardware store, home center, electric supply, lighting store, internet Buy: Terminal kit at Amazon with crimp tool Electrical terminals at Amazon Blue 14-16 gauge female terminals 20 pcs at Amazon Yellow 12-10 gauge female terminal 16 pcs 360 pc assortment at Amazon |
Rotate dial until current time shows on clock face |
|
Talento 111 timer wiring More din rail timers with similar wiring Resources Talento 111 mini 211 mini manual Talento 111, 121, 171, 211, 271, 212, 202 How to set analog timers Intermatic Talento timers Hagar Tork Onesto Fato and Misc How to wire Din Rail timers |
|
Timer has green ground wire Ground wire not shown. |
ST01C
digital timer controls any
voltage 7-day Digital timer/ programmable or astronomic Battery operated CR2 battery Single-pole or 3-way 50-60 Hz/ 24 volt AC, 12 volt DC/ 120-277V Buy: Intermatic ST01c timer at Amazon Intermatic ST01 timer CR2 replacement battery at Amazon CFL bulbs at Amazon 120Volt coil At Amazon 240Volt coil At Amazon Buy: Buy fuseholders ANL fuseholder Fuse blocks Electrical terminals Din rail fuseholder 10 x 38 mm fuse Resources: ST01 timer manual Load ratings for Intermatic timers/ pdf How to program and wire Wire ST01 timer More Intermatic timers Fuseholders Contactors |
Contactors/ relays |
|
|
Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |