Waterheatertimer on Twitter |
How
to remove broken light bulb Safe electric wiring |
Light bulb might get
broken or break off when unscrewing from socket... To prevent stuck bulb: spray WD40 to aluminum part of new bulb before screwing into light fixture... don't breathe WD40 vapor, and be mindful WD40 vapor is extremely flammable. Tools needed: Very small flat-tip screwdriver and needle nose pliers Turn power off, wear safety goggles Remove as much glass as possible using needle nose pliers Use small screwdriver and pry aluminum part of bulb inward away from socket all the way around the perimeter. Grab onto the aluminum with needle pliers Roll the needle nose pliers in same direction as unscrewing light bulb. Aluminum part of bulb will start to wrap around the pliers until the bulb finally unscrews. |
Multimeter Test for breaks in wire/ Test for voltage Most appliance require 80% rated voltage to function correctly Buy Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line Resource: How to test and replace element How to test thermocouple Element tests for 120 volts How to test wire |
Safety
when testing wires:
Never touch wet or previously flooded appliance. Never stand on wet surface when working on electric. Never stand on bare soil, put down dry boards. Tape tester leads to wood sticks to keep hands away from power. Use non-contact voltage tester before touching wires. Never touch or lean into any made of metal. Remove metal objects from pockets. Do not use oxygen or fuel accelerants in same room as electrical repairs Resource: Basic house wiring |
Non-contact voltage tester Test for power without touching connectors NEVER assume power is OFF Buy: Non-contact voltage tester Amazon Electric testers at Amazon Resource: How to test electric power is off |
120 volt 15 amp devices
including GFCI, timers, switches, plugs, wifi controls etc can be
installed on 15 or 20
amp
breaker. 120 volt GFCI, outlet, receptacle that is rated 20 amp can be installed on 20 amp breaker only, but NOT on 15 amp breaker. Buy 15 amp GFCI 20 amp GFCI |
Buy Basic electric book Home plumbing/ electrical codes Or learn about basic household electricity... use and search my site/ Resource Safe electric wiring Basic house wiring |
Use outlet tester to check for correct wiring on any 120 volt straight-blade outlet. Buy: Klein testers Outlet tester Circuit breaker finder Electric usage monitor |
Non metallic flexible cables must carry ground wire, but do not have hazard of short circuit causing injury from shock. Armored steel cable can be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure. All conduit ...metal, plastic ... flexible and rigid ... must be attached to structure, and attached to enclosures, boxes. Movement, damage and deterioration are major cause of electrical failure. Buy: Non-metallic flexible conduit Power whip Armored cable Southwire armored cable cutter Pull boxes |
Electrical tools must be insulated. Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off. Buy: Electrician tools kits KLEIN TOOLS Tools kits IRWIN tools KNIPEX |
Connect wire to screw terminal Use only 600 volt solid copper wire. Do not use stranded wire or extension cord. Do not use solder anywhere on residential 120-240 volt wiring. Attach electric installation to structure. Tighten screws very tight against wire. Buy: NEC books Dewalt plumbing/ electrical codes Basic electric book National electric code guide/ illustrated Resources: How to twist wire How to select and install twist-on wire connectors |
Weatherproof
lever switch on outdoor lights Safely operate outdoor toggle switch Replaces outdoor cover Install over top of ordinary switch Works with single-pole, double-pole, 3PST, 3-way, 4-way switches etc Use weatherproof box for outdoor Can be used indoor or outdoor Buy: Best choice: Cantex lever switch Outdoor lever switches at Amazon Lever switches Resource Cantex-toggle-switch-covers.pdf Cantex-PVC-junction-boxes.pdf |
TerminalsBuy:Terminal kit Blue for 16-14 wire Yellow for 12-10 wire Resource: How to install terminal |
Push-on wire connectors in place of twist-on connectorsBuy:Push on wire connectors Amazon Red 3P connector for 10-14 gauge wire Lever connectors for stranded wire at Amazon |
Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. Code -Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon |
When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistances on wire and creates weak point. Buy tools: Wire strippers at Amazon Linesman pliers Pro linesman plier Needle nose pliers End cutting nippers at Amazon |
Weather resistant plastic box for outdoor extension cord connections, Christmas lights, outdoor power strip etc . Not for connecting wires with wire nutsŪ, or in-wall wiring, but can be used indoors to organize extension cords, power strips etc. Weather resistant is not weatherproof or watertight. Use enclosures rated IP65 and IP67 for waterproof. Extension cords cannot be used for permanent wiring. Buy: Large-medium-small electric cord box Socketbox Raintight enclosures Water-tight cord lock Resource: Enclosures and boxes |
Each electrical device has a rating plate with amps and watts 14 amp device is ok on 20-30 amp line 20 amp device is ok on 30 amp line 20 amp device is not ok on 15 amp line 30 amp device is not ok on 20 amp line Resources: How to wire switches How to add a switch Replace outlet with combo switch How to add outlet How to wire Combo switches |
Ground outdoor motors and boxes Never use ground for Neutral Never use Neutral for ground Using ground as a Neutral can cause the short circuit and potential fire to detour into the device that is improperly connected. Bond all grounds together to help protect against surge and lightning damage. Resources: Why you need ground wire Difference ground vs surge |
GFCI breakers and outlets trip faster than ordinary circuit breaker to protect from shock caused by short to ground. AFCI does the same plus trips when spark is detected. Install GFCI in bathrooms, kitchen, laundry room, and on all outdoor plugs. Resources: How to wire GFCI and AFCI What causes electrocution |
Not enough space for circuit breakers How to add tandem breaker How to install subpanel How to replace circuit breaker Buy: 124TP2608A 4 breaker spaces 124T2530A 8 breaker spaces |
Under counter water heaters are used to provide hot water to smaller consumption areas or to supplement or replace main water heater. When adding appliances, check the rating plate for volts and amps. Always match wire and breaker size. Resource: How to wire under counter water heater |
Electric Tankless water heaters are used as main water heater, or as supplement to supply one area. Wiring is straightforward if the circuit breaker panel has enough spaces and capacity for the amp draw. Resource: How to wire Tankless water heater |
Every electrical device and connection needs to be contained within an enclosure with cover. Secure wires and conduit to structure using staples, clamps etc. so the wire cannot come loose. Wire ends should be twisted together and covered with wire connector. Resources: Enclosures Romex connectors How to twist wire Wire connectors/ |
Weatherproof lever switch on outdoor lights Safely operate outdoor toggle switch Replaces outdoor cover Install over top of ordinary switch Works with single-pole, double-pole, 3PST, 3-way, 4-way switches etc Use weatherproof box for outdoor Can be used indoor or outdoor Buy: Best choice: Cantex lever switch Outdoor lever switches at Amazon Lever switches Resource Cantex-toggle-switch-covers.pdf Cantex-PVC-junction-boxes.pdf |
Safety switch Resource: How to wire safety switches |
Surge Protection is a consumable product that absorbs irregular voltage and protects circuits from damage. Resource: How to wire surge protection |
Subpanels are used to expand electric service by adding more breaker spaces Resource: How to wire subpanel |
240 volt outlets are used for window air conditioner, RV hook-ups, electric car, dryer, range welder etc Resources: How to wire 240 volt outlets How to wire twist lock devices |
Buy Electronic parts Industrial supplies Tools and home improvement Home and garden Hayward pool Pentair pool Southwire electric |
|
Buy
Tools DEWALT Black and Decker Stanley SKIL Makita Porter-Cable Bosch Irwin Hand tools Klein hand tools Fluke electrical testing Dremel hobby tools Campbell Hausfeld air powered Tekton automotive Powerbuilt automotive Saws and saw blades |
|
Resource: Compare box timers DPDT timers Intermatic Control water heater w/ Z-wave |
|
Resource: Intermatic control centers: and parts Digital control centers and parts Tork control centers and parts Subpanels All control centers and parts Enclosures |
|
Resource: Programmable timers Countdown timers Off delay timers On delay timers Timer modules Din rail Twin & one-shot Woods Intermatic Tork |
|
Recirculation systems |
Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |