Is there a universal water heater gas valve? NO
E-mail: geno03245w@gmail.com

Back to 14 things needed for gas water heater
Do they make a universal water heater gas valve?

No such thing ... because the flow of gas to pilot and burner much match the BTU output of heater...
Some residential heaters are 30,000 ... some 40,000 ... a few are 50,000... Resource: Typical spec sheet
They make high volume residential heaters up to 199,000 BTU   Resource Polaris water heater
Then propane is different than natural gas... and then there's the oil-fired heater
There are heaters with no pilot light ... Resource Troubleshoot power vent water heaters
Some heaters have pancake burners, while others have low nox burners ... Resource: basic parts for gas water heater
And commercial heaters with massive burners and higher gas pressures  Resource: Typical spec sheet
And boilers that heat water and space for entire house or building ... can reach giant proportions

The gas valve manufacturer's probably have standardized gas valves to meet each need ... and then water heater and appliance manufacturers build around those specs
Honeywell WV8840 circuit boardInside gas control
Honeywell electronic gas controls receive power from thermopile that supplies electric current to a circuit board (see images).
The circuit board has 3 connection points that supply power to electromagnets.
The main gas supply magnet shuts off gas to pilot and burner if TCO trips or if pilot light goes out, or if water heater is turned off.

The manifold magnet responds to temperature measurements and turns gas on to main burner during the call for heat.

Mechanical gas control valves also have electromagnet that receives current from thermocouple (see image), but there is no circuit board.

The gas supply must be kept dry and clean or the gas control can clog and fail. When working on water heaters, installing and repairing, care must be taken to keep gas lines clean. Any debris or moisture entering gas valve can cause failure, requiring replacement of gas valve.

Back to 10 things for troubleshooting water heater
Icon gas valve
For atmospheric vent models
Range Low 55° - very hot 160°
Average bath 110°F, typical water heater temp 120°
ECO limit 199° F, ECO trips, gas valve fails
TP release water at 170°
All calibrations are approximate
Severe scalding risk over 135°
To reset gas control, rotate dial to OFF, wait 10 minutes for gas to clear. Then relight.
Buy
Reliance/ Honeywell gas control
American / Honeywell gas control
Kenmore water heater gas valve
Craftmaster/ Whirlpool
Bradford White
AO Smith

Honeywell gas control at Amazon
American / Honeywell gas control at Amazon
Honeywell gas valve for propane
Honeywell natural gas valve
Reliance NG at Amazon
Reliance LP at Amazon
Kenmore water heater gas valve
Gas water heater timer fits this valve
Replacement instructions
How to test & replace Honeywell/ pdf
WT8840 replacement manual
How to replace Honeywell gas control valve

Resources WV8840/ WT8840:
Typical installation manual
Typical installation manual/ low NOx
Adjust temp on Honeywell gas valve
Error codes WV8840 series
Error codes WV8840 series
Error codes WT8840
AO Smith service handbook
Service handbook
State Error code/ troubleshoot/ service manual/ FVIR
Bradford White service manual
Error light blinking 4 times
How to light water heater
How to light water heater/ pdf
How to light Whirlpool energy smart

WT8840 product overview models
WT8840 gas valve manual and troubleshoot

How to replace gas control valves
How to test gas control valve

How to install gas water heater

For power vent and flue dampered models
Range Low 90° - very hot 160°
Average bath 110°F, typical water heater temp 120°
ECO limit 199°F, ECO trips, gas valve fails
Average bath 110°F
ECO limit 199°F
TP release water  at 170°
Buy
Example Honeywell gas control valve at Amazon
Reliance NG at Amazon
Replacement instructions
How to replace water heater gas valve

Resources:
Flue dampered service manual/ atmospheric
Flue dampered/general install and troubleshoot
Dampered troubleshoot codes
Dampered error codes
Dampered error codes
Induced draft troubleshoot codes
Example dampered install manual2

Example power vent install manual
Example power vent install manual
Example power direct vent install manual
Adjust temperature/ error codes on Honeywell
How to light Honeywell gas valve
Error codes and troubleshoot chart
Error codes
Error codes
Icon gas valve error codes

AO Smith service handbook
Bradford White power vent service manual 1
Bradford White power-vent service manual 2
Bradford power-direct-vent service manual
Condensing power vent service manual
Test gas control/ from BW service manual
Sequence of operation
How to clean burner

Safety
Water heater safety precautions
Water heater precautions/ pdf
Gas-water-heater-Safety-Precautions
Gas valve safety
Thermal expansion
Insulation blanket

For power vent models
Range Low 80° to Hot 150°
Error C flashes at 160°
Buy
Buy Intellivent gas control at Amazon
White Rodgers/ Rheem Intellivent gas control
AO Smith intellivent
AO Smith Intellivent at Amazon
AO Smith White Rodgers at Amazon

Replacement instructions
How to replace water heater gas valve

Resources:
How to light water heater
Typical installation manual
Sample installation manual
Example install manual
Ultra low nox power vent manual
Error codes and adjust temp on Intelli-vent
AO Smith Intellivent troubleshoot and FV test
Troubleshoot Intellivent/ pdf
FVIR intellivent troubleshoot .pdf
Intellivent service manual TC-048 R6
Sequence of operation and service brief
Intellivent wiring
Power direct vent troubleshoot
Status codes and troubleshoot/ condensing
How to reset intellivent
For resetting controller:
Method A... After the unit has been off for at least a minute, plug it in, turn on switch; within a few seconds, depress both arrow buttons on controller, and hold them until the left light begins to blink.  Release them, and within a few seconds, push those arrow buttons in the following sequence:  L/R/L/L/R/L/R/R.  This should reset the controller.
Method B... after FV event on AO Smith
1. Turn off power to water heater for 10 seconds.
2. Restore power to water heater.
3. Within 10 seconds of restoring power, press the two temperature adjust buttons simultaneously until the left (green) “Vacation” LED begins to blink (approx. 5 second delay). Once the Vacation LED begins to blink, release both buttons.
4. Again, within 10 seconds, press both temperature adjust buttons simultaneously until
Vacation LED is on steady (approx. 5 second delay).
5. Release two buttons, the  microcomputer will clear the FVS lock-out and normal
operation will then be restored.
Support the economy:
Buy water heaters from my associate links:

50 gallon Gas water heaters at Amazon
40 gallon gas water heaters at Amazon
50 gallon Electric water heaters at Amazon
40 gallon electric water heaters at Amazon
Hybrid / heat pump/ water heaters at Amazon

Resources:
How to install gas water heater
How to install electric water heater
Troubleshoot gas water heater
Troubleshoot electric water heater
Point of use water heaters
Resources:
Troubleshoot Gas valves with manuals
Icon gas valve

How to replace water heater element Waste King disposal
How to wire tankless electric


Install point of use water heater
Titan tankless

Contactors/ relays
Install and troubleshoot garbage disposal Waste King disposal
Programmable timers

Woods timers
surge protection
Anode rods anode rods
Recirculation system

Tankless recirculation
Point of use water heater
Type 1 and type 2 surge protection surge protection
Buy
Industrial electric

Industrial supplies

Tools and home improvement

Home and garden

Hayward pool
Pentair pool

Southwire electric
Buy
Tools

DEWALT
Black and Decker
Stanley
SKIL
Makita
Porter-Cable
Bosch

Irwin Hand tools
Klein hand tools
Fluke electrical testing
Dremel hobby tools

Campbell Hausfeld air powered
Tekton automotive

Powerbuilt automotive
Saws and saw blades
box timers Resource:
Compare box timers
DPDT timers
Intermatic
Control water heater w/ Z-wave
Intermatic control centers Resource:
Intermatic control centers: and parts
Digital control centers and parts
Tork control centers and parts
Subpanels
All control centers and parts
Enclosures
programmable timer Resource:
Programmable timers
Countdown timers
Off delay timers
On delay timers
Timer modules
Din rail
Twin & one-shot
Plug-in timers
Woods
Intermatic
Tork
Low voltage power packs Recirculation systems
Buy from my affiliate links every time/ thanks:
Amazon
As an Amazon Associate I earn from qualifying purchases
Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission

E-mail: geno03245w@gmail.com
My response might end up in spam folder, check email folders
Waterheatertimer on Twitter
Message thru facebook