Larger water heaters
Which is best gas water heater
Maintain your water heater
Waterheatertimer.org
is a self-help site
Emergency steps to turn off water heater
Figure Volts Amps Watts for water heater How to wire tankless electric
How to install point of use water heater Point of use water heater
Compare 16 electric and 3 gas water heater timers Troubleshoot Rheem tankless Figure correct wire and breaker 9 ways to save with water heater
How to install recirculation system Point of use water heater
T100 series timers Programmable wall timers Auto-off timers Box timers How to set timers
How electric water heater works Troubleshoot electric water heater Troubleshoot gas water heater How to wire subpanel
Type 1 and type 2 surge protection surge protection
2016
Search waterheatertimer.org / all results
Search using Find button  

 Tweet button  

How to install point of use water heater/ strategy for downsizing main water heater

Buy:
Under counter water heaters at Amazon
Point of use water heaters at Amazon

Under-counter/ point-of-use water heaters shown here are electric
What size do you need? If you need to run out 1 gallon before getting hot water, then use 3 gallon under-counter

120V hardwire / 3/4" connections/ Fully repairable by homeowner
Reliance water heater
Reliance 120 volt/ 1600 watt
6-10 gallon
Side connections/
6 year warranty
Buy:
Reliance water heaters
12 ga extension cords
12-2 Southwire cable
Resources
Reliance manual
State manual
American tiny titan water heater
American 120V/ 1500 watt
6-12 gal
Top connections/
6 year warranty
Buy:
American 12 gallon
12-2 Southwire cable
Resource:
American manual
State point of use water heater
Rheem
2-6-10-20 gallon
Side connections/
6 year warranty
Buy:
Rheem point of use
12-2 Southwire cable
Resource:
Rheem manual
COLD side Sharkbite flexible water heater connector

Buy:
Sharkbite water heater connection
Braided water heater line
Copper flexible connection

Advisory about stainless connections: Stainless is reactive with softened water, will cause deterioration of stainless.
Stainless steel connection
water heater stand
Buy:
Holdrite at Amazon
Steel pegboard
Hyloft storage hardware
Garage storage

Resource:
Use 20 gallon water heater for tankless recirculation

Plug into 120V 3-prong outlet/ Temperature control on front/ 2.5 - 6 gallon/ Non-generic parts/ Repairable
Ariston water heater
Ariston / Bosch
2.5 - 4 gallon  - 7 gallon
Top connections/
2 year warranty
Buy:
Ariston at Amazon
Bosch at Amazon
Resources:
Ariston resources
Bosch P10 P5
State point of use water heater
State / Reliance
American/ are all AO Smith
2.5 - 6 gallon
Top connections/
6 year warranty
Buy:
Reliance 2.5 gal Amazon
Resource:
Reliance manual
Waiwela awter heater
Waiwela
2.5 - 4 gallon
Top connections
6 year tank warranty
Buy:
Waiwela at Amazon
Resource:
Waiwela mini tank
Emax point of use water heater
Eemax
1.3 - 2.5 - 4 - 6 gallon
6 year tank warranty
Buy:
Eemax water heaters
Chronomite 2.5 gallon
Resource:
Eemax manual/ parts
Stiebel-Eltron point of use
Stiebel Eltron
2.5 - 4 gallon
Top connections
2 year warranty
Buy:
Stiebel Eltron water heater
Resource:
Steible 2.5 manual
 Resource How to wire tankless electric

Tankless/ 120-240V hardwire/ 30 amp 10 gauge wire/ Tankless units are connected to incoming cold water line. Not DIY repair/ cannot be exposed to hard water.
Requires dedicated circuit with no other load on breaker
Resources
 How to wire tankless electric
Match breaker size and wire
tankless under counter
Atmor tankless
2 year parts-7 year leak warranty
120-240 volt models
Buy: at Amazon
120 Volt 30 amp Amazon

Resources:
Atmor Installation manual

How to wire tankless electric

Match breaker size and wire
Eemax point of use water heater
Eemax tankless
Hardwire 120 Volt
7" x 11" x 3"
Buy:
Eemax SP3512 120V
3500 watt/ 30-40 amp
Eemax SP35 240Volt

Resources:
Eemax tankless manual
Sell sheet with wire size chart
Troubleshoot
Ecosmart point of use
EcoSmart tankless
Tankless
Hardwire 120 Volt
7" x 11" x 3"
.25 gpm
Buy:
EcoSmart water heater
3500 watt/ 30-40 amp
6000 watt/ 30-40 amp
18,000 watt/two 40 amp

Resources:
EcoSmart manual
EcoSmart troubleshoot
How to wire tankless electric
Stieble Etron point of use
Stieble Eltron Mini/ tankless
Tankless
Hardwire 120 Volt
Buy:
Stieble mini 120V Amazon
3000 watt 30 amp
Stieble mini 6 240 Volt
5700 watt 30 amp
Stieble DHC 3-1 120 Volt
300 watt 30 amp
Stieble DHC 6-2 240 Volt
6000 watt 30 amp

Resources:
Steible Eltron mini manual
Stieble DCH manual
Chronomite tankless water heater
Chronomite Tankless
Hardwire 120 and 240V models
Buy: at Amazon
Chronomite water heater

Resource:
Chronomite manual

Buy
Bosch 3.4 120V
3400 watt/ 30 amp
Bosch 9.5 240 Volt
9500 watt/ 40 amp

Resource::
Bosch powerstar manual

1) What size tank water heater?
1:3 rule of thumb:
If 1 gallon runs out before hot water arrives, then 3 gallon water heater is correct size.
Before choosing: Look at Hot-cold Options below.

Buy:
Under counter water heaters 
Point of use water heaters 
2) Pay attention to Hot and Cold inlets
If hot-cold inlets are reversed, tank will not perform as expected.
Incoming cold water must connect to Cold inlet at bottom of water heater
under counter water heater
a) Spend more for more hot water.
b) Spend less for less hot water

Buy:
Chrome shut off valves 
3) Connect water heater to hot or cold?
Do you connect the inlet to Cold water source, or connect to hot source (that comes from main water heater)?

Option A: Connect to Hot source
. See image
This option draws hot water from main water heater ... so when the under counter tank runs out of hot water, more hot water arrives from main tank and temperature stays hot.
Advantage: Quick delivery of Hot, with plenty more hot on the way.
Disadvantage: If you are just washing hands or don't use much hot at that tap, then Option A costs more because cold water enters the main water heater each time hot is turned on.

Option B: Connect to Cold source. See image
When using under-counter water heater for hand-washing, this is best option
Advantage: Quick delivery of Hot, without drawing cold water into main water heater.
Disadvantage: The supply of hot at the tap is limited to what the small tank can supply.

Larger image
Option A/ Connect to Hot source:
hot water arrives from main tank as under-counter tank runs out of hot.
Connect hot water source to the cold water inlet on tank
Use teflon tape on threads

Advantage option a: Plenty of Hot water.
Problem with option a: Costs more. Each time small amount of hot is drawn from faucet, equal amount of cold water immediately enters main water heater. This causes the main water heater to operate more.
How to solder pipe
Install under counter water heaterLarger image
Option B/ Connect to Cold source:

spend less/ hot water limited to amount inside under-counter tank.
When using under-counter water heater for hand-washing, this is best option.
When installing tankless, use this option.

Problem with option b: Hot water supply is limited to amount of hot water in under counter tank. Under counter water heater supplies all hot water at faucet.
Advantage option b: Costs less. Each time hot is drawn from faucet, cold water does not enter main water heater.

Connect cold water source to the cold water inlet on tank. Hot source pipe is capped.
Use teflon tape on threads
How to solder pipe
GE20P06SAG
Larger image
shut off valveWhat if... no drain valve on tank?
Some small tank type heater do not come with drain valve.
Install drain valve on cold water inlet
Install shut-off on cold water line

Drain the water heater?
Remove TP valve and siphon water from tank

Buy:
Lead-free ball valve 
Chrome shut off valves 
Pot heater
Buy:
Kettle heaters
Other options/ Instead of installing under counter heater
a) Use kettle heater/ note that 1500 watt kettle heater consumes as much power as microwave oven, and can quickly overamp a 15 or 20 amp circuit breaker if circuit has other Loads operating at same time.
b) DIY solar: Set 2 gallons water outside in sun each day
c) Install recirculation system
How to install recirculation system Point of use water heater
4) Do not drop water heater
Can break element, or damage outer shell. Interior steel tank would be hard to damage.
Check elements ... if OK, then water heater should work
Do not call the manufacturer and report problem, or warranty will be compromised.
Resource
How to troubleshoot electric water heater
5) Earthquake straps / safety
Earthquake areas ... Secure water heater to structure to avoid pipes and electrical coming loose.
Tank type electric water heaters can be set on or against any wood, carpet, plastic etc surface.
Electrical connections must be made inside electrically rated box or enclosure. No homemade boxes, covers etc. Hardwired heaters must be connected using 600 volt sheathed cable. No extension cords, unless plugged directly into outlet.
Cover all electrical boxes and connections with electrically rated cover that matches box. Cover must stay in place.
Electrical connections can be at top or on side.. Secure wire and conduit to structure.
Buy:
Earthquake straps 
Resources
See earthquake strap illustration  
TP valve code
Drip pan
Drip pan
6) Drip pan saves damage
Drip pan saves damage
Resource:
See drip pan installation
Buy:
Water heater drip pans 
Buy:
Water detectors 
Auto-shut-off valve 
7) TP overflow code
Overflow tube cannot be inserted inside drain line, capped off, or be terminated where it can cause damage if TP releases water.
Temperature-pressure relief valve is required for safe operation of water heater. DO NOT CAP OFF.
TP spews scalding water when internal temperature and pressures exceed safe limits. This prevents water heater explosion. Direct overflow tube to nearby drain or to outside.
Overflow tube must be as short as possible and same diameter as valve discharge connection. Do not downsize into smaller pipe. Overflow tube maximum 4 elbows and 30 feet length. Overflow must terminate 6" above drain or water line.
Ideal to vent TP directly outdoors ending in a downward pipe. Overflow pipe must pitch downward, and cannot be under water. TP valve can draw water back into water heater if end of overflow tube is under water. End of overflow tube cannot be threaded.
Gently open and close TP valve once each 1-3 years to make sure valve is functioning.
Resource
How to test, maintain, and replace TP valve
Solder copper pipes Soldering copper pipes?

Most under-counter 6 gallon and 12 gallon water heaters have 1/2" connections.

Avoid soldering directly to water heater.
First, solder piece of pipe to male or female adapter, and then attach adapter to water heater.
This will avoid direct torch heat on water heater.
Resource
How to solder copper pipes


8) Insulate pipes, top of TP valve, and tank

Do NOT block TP valve lever
Electric water heater can be totally covered with insulation except TP valve
Element burns out
Tank must be full of water
9) Tank MUST be full of water before applying power
Element will instantly burn out if tank is not full of water.

Fill tank completely until faucet is running full stream
THEN open TP valve momentarily to release last of air from top of tank.
Once tank is full of water, power can be turned ON.
Resources
How to test element

Troubleshoot and service guide
How to troubleshoot electric water heater

Point of use service manual
Bosch Ariston resources
How to maintain water heaters
Commercial point of use service manual

For tankless electric:
How to wire tankless electric water heater
Other manuals:

Hubble 2.5 gallon manual
Bradford White instantaneous
Emerson point of use
Insinkerator manuals
Boil water faucet- new product

Water heater manufacturers
Finished install

Larger image
Showing side connections, electric conduit top of tank, drain pan and TP overflow tube going to floor drain. Allow 6" space between TP overflow tube and floor drain.
Or overflow tube can be directed outdoors
Does not show drain valve installed.
Under counter water heater
Larger image

Showing 120 volt plug and outlet for some models.
Do not use extension cord.
Outlet must have correct polarity and be grounded.
Check outlet with circuit analyze.
TP overflow tube has 6" space above floor drain.
Drip pan has overflow tube touching floor drain.

Resource
Basic House wiring

Larger image
Showing drain valve installed on cold water inlet
Showing location of anode rod

Resource
How to replace anode rod
Electricity to Under counter water heater


Never assume power is OFF
Use non-contact voltage tester on timer, on wire, on outlet to see if power is present.
Press button on tester, if single beep then no power is present. If continuous beep then power is present.
Never stand on bare ground, always stand on dry boards, do not hold or touch anything metal when working on timer or water heater that has power, tape tester leads to wood sticks, never touch wet water heater, or flooded water heater, or timer that had a short or fire without turning power OFF.

Buy:
Multimeters 
Buy non-contact voltage tester 
Electric testers
Test water heater
120Volt water heater
color-code household wire120 volt water heater has Black and white wire
Code says: use only approved 600 volt electrical wire. Do not use stranded wire for 14-12-10 gauge wiring. Use solid copper wire. Never use extension cord for permanent household wiring. Always connect ground wire. Make sure all connections are inside electrically rated enclosure with cover that fits.
Typical 12-2, 120Volt electrical line has Black Hot, White Neutral, and bare ground.
Connect black to black and white to white.
Ground wire must be connected to ground screw.
Join wires using twist on wire connector and twist very tight ... make sure all bare copper is covered.

Resources
How to twist wire and install wire connectors
How to drop wire from attic
Color code and wire rating
Put cover over all electrical connections.
Calculate electrical demand
1) Read label on side of water heater. Find watt and volt rating.
Watts divided by 120Volts = amperage
120Volt 1500 watt water heater consumes 12.2 amps.

2) Read label on dishwasher: Typical dishwasher consumes 6-11 amp at max draw.

3) Label circuit breaker that connects to dishwasher. Check other loads (lights, TV, etc) that are connected to same breaker. Add up total wattage of all items on breaker. Divide wattage by 120Volt to find total amp draw on breaker. Add 6-11 amps drawn by dishwasher to find total load.

4) Can you safely add another 12.2 amp water heater to the circuit?
Electrical capacity calculation:
1) 15 amp breaker with 14 gauge wire is recommended at 80% rated load = 12 amp load.
2) 20 amp breaker with 12 gauge wire is recommended at 80% rated load = 16 amp load.

3) Combined load for dishwasher and water heater is 18.5-22.3 Amps.
If you have 15 amp breaker or 20 amp breaker, then dishwasher and water heater should not be turned ON at same time.

Hubble 750-1000 watt 2-1/2 gallon with 1/4" male connections

1500 Watt 2-1/2 to 6 gallon


Typical 1500 watt 20 gallon
No wire available for 120 volt installation?
120 volt under counter water heater requires dedicated breaker that serves no other appliance.
What if you can't run another wire from the breaker box. No problem, split duty with the dishwasher, or microwave oven.
The water heater does not need power full time. Dishwasher is only used now and then. Use a switch or a timer to toggle between each load.
water heater circuitBuy:
Dishwashers 
How to toggle between under counter water heater and dishwasher

Same wiring for either 120 or 240 volt loads
Code permits 15 or 20 amp switch on a 20 amp breaker ... as long as switch is rated for same voltage and more amps than Load (anything that consumes power is Load).
Use only approved 600 volt, solid copper wire under screw terminals. Never use extension cord for permanent household wiring, unless plugged into outlet.
Hardwired water heaters can be wired to 12 gauge extension cord, then plugged into outlet ... do not use 14 gauge cord.


Objective: Either the dishwasher has power or the under-counter water heater has power. But neither at same time. Why? Because safe maximum amps on 20 amp breaker is 80% or 16 amps ... while dishwasher and water heater together consume 23 amps.
Do not install 30 amp circuit breaker unless wire is also increased in size from 12 ga to 10 gauge. Color code for wire

How to wire: Incoming wire from breaker has 2 wires. If voltage is 120, then the white Neutral wire is never switched on-off. Connect white Neutral wire to each appliance.
Black Hot wire is switched on-off. Connect Hot wire to COM terminal on the 3-way switch (dark or different color screw). Then run a Hot wire to each appliance from the other two screws on switched.

Heavier amp loads, or more voltage, such as 30 amp 240 volt water heater, use a 30 amp 3-way switch (safe max 23 amps).
Other options, for higher amperage loads and motor loads (such as irrigation pumps, shop tools etc), include using a switch (or timer) to toggle loads with 30-40 amp open frame relay.
For heavier amp loads, or 240 volt ...Buy:
Leviton 3033 switch 
30 amp 3-way switch
Resource:
How to wire open frame relay
water heater circuit Larger image
Toggle between under counter water heater and dishwasher using small timer
Small FM1 timer module is reliable, long lasting, and rated 15 amps.
Timer can be installed inside a small plastic enclosure, and then install box cover.
Buy 24 hour 120 volt
FM1STUZ/ 24-120-240 Volt  timer models
Larger imageFM-1 timer
Example wiring:

1) Buy plastic box with 3/4 Knockout. Or drill 1" hole.
2) Use 3/4" male adapter so all 3 wires enter box from same knock-out.
3) Attach timer with self-tapping screws.
4) Remove timer from box to connect terminal ends to timer
5) In this illustration, I trimmed the ground wires shorter and re-applied wire connector so all wires could fit into box before putting cover over box.
6) Attach box next to water heater. Make box accessible so times can be changed. Timer must be re-set to current time after power outage.
FM1 timer
Larger image
Wire 1500 watt water heater to FM1 timer
FM1 timer rated for 21 amps/ max 2000 watts
21 amp x 120volt = 2520 watt x 80% = 2016 watts

Buy: FM1 timer module/ 7-day or 24 hour
Intermatic/ Grasslin FM1 timers 
24-hour 14 minute 120Volt 60 Hz 
7-day 2 hour increments 120volt 60 Hz 
24-Hour 240Volt 60 Hz 
7-day 240Volt 60 Hz 
Intermatic T1906
Large image of 120Volt T1975
T1975  timer with NO and NC terminals
20 amp rating
Each tripper: 15 minute intervals. 4 consecutive trippers = 1 hour.
If you want dishwasher circuit available from 7 to 10 PM, install twelve consecutive trippers starting at 7pm and ending at 10pm.
Remaining hours of the day, the water heater is ON.
Resource:
How to wire T1905 and T1975

Alternate timer with same wiring T1905

Buy timer:
T1905 series 120Volt 20 amp 1 Hp timer at Amazon

Intermatic 156T1950A tripper
156T1950A tripper
T-1975 wiring Wiring diagram for T1975

Water heater is ON at all times except when timer turns ON.
To reverse, so heater is OFF, switch black wires on NO NC terminals
Water heater connected to Normally Closed terminal.
Dish washer connected to Normally Open terminal
When timer activates, water heater turns OFF, and circuit to dish washer is ON.
Resource:
How to wire T1905 and T1975
Intermatic timers and manuals
Intermatic T2000 timer
Larger image

T2000 7-day timer/ indoor box/ 42-on-off/ 2 hour minimum on-off/ 6 on-off per day/ 20 amp/ SPDT

120V and 208-277V
42 ON 42 OFF per week
Minimum ON-OFF 2 hours
6 ON-OFF per day
NO NC terminals SPDT

Buy:
T2005 120 Volt at Amazon
T2006 208-277 volt at Amazon
Parts:
Replacement 156T1950A trippers at Amazon
WG720 120Volt clock motor at Amazon
WG723 208-277Volt clock motor
Replacement snap switch 133T701A

Resources:

T2000 sell sheet
T2005 Manual
T2006 Manual

Wiring diagram for T2005

Connect 120 Volt water heater as shown

Add dishwasher:
Connect dishwasher black wire to NC terminal.
Connect  dishwasher neutral wire to other white neutral wires.
Wire GE15207 for under counter water heater
Wiring diagram for GE 15207 timer
How to wire GE 15207 timer to control 240Volt load
GE timers and manuals
Timer toggle between applainces
Larger image
Buy:
Dishwashers at Amazon

Other timers with NO NC contacts/ toggle circuit between appliances/ applies to 120V or 240V

Tork TU series timer
GM40
GMQ series
GM40AV
GM40AVE
Woods 59402
Tork DTU series
GE 15207
GE 15132

See all these timers together
Gas and electric water heaters Support the economy:
Buy water heaters  from my associate links:

50 gallon Gas water heaters at Amazon
40 gallon gas water heaters at Amazon
50 gallon Electric water heaters at Amazon
40 gallon electric water heaters at Amazon
Hybrid / heat pump/ water heaters at Amazon

Resources:
How to install gas water heater
How to install electric water heater
Troubleshoot gas water heater
Troubleshoot electric water heater
Point of use water heaters
Gas and electric water heaters Industrial electric at Amazon

Industrial supplies at Amazon

Industrial and scientific Amazon
Tools
Shop Amazon - DEWALT
Shop Amazon - Black and Decker
Shop Amazon - Stanley Tools
Shop Amazon - SKIL Tools
Shop Amazon - Porter-Cable Tools
Shop Amazon - Bosch Tools
Shop Amazon saws and saw blades
box timers Compare box timers

Control water heater w/ Z-wave
Intermatic control centers Control centers:
+ manuals and parts


All control centers and parts

Including Z-wave
programmable timer Compare programmable timers

Control water heater with programmable wall timer
Countdown timers Compare countdown timers

Control water heater with countdown timer

Buy from my affiliate links every time/ thanks:
Amazon
As an Amazon Associate I earn from qualifying purchases
Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission

E-mail: geno03245w@gmail.com
My response might end up in spam folder, check email folders
Waterheatertimer on Twitter
Message thru facebook