What is Thermal Expansion
Closed system
 
Use 6 wraps teflon tape
White for water lines
Yellow for gas lines

Buy:
Teflon tape at Amazon

Buy:
Pipe wrench at Amazon
Channel locks

Resources:
How to remove rusted element


Buy:
Knipex channel locks
Irwin pliers
replace anode rod
Inspect anode each 2-5 years
Anode rod prevents tank from rusting
Buy:
Anode rods at Amazon

Resources:
Replace anode rod
How to maintain water heater

Buy:
Impact wrench at Amazon

Resources:
Replace anode rod
How to remove short water heater nipple
Water pressure gauge

Pressure gauge/ attach to water heater drain valve
Pressure over 80 psi can damage water heater and household plumbing
Buy:
Water pressure gauge
Watts telltale Pressure Gauge 276H300
Temperature-pressure gauge

Resources:
Identify water heater valves
Troubleshoot water pressure
Automatic water heater shut off valve
Prevent flood
Automatic water shut off valve
Buy:
Water detectors at Amazon
Automatic water heater leak shut off at Amazon
Resources:
Leaking water heater/ steps
Pressure reducing valve
Pressure reducing valve
Pressure over 80 psi can damage water heater and household plumbing
Buy:
Pressure reducing valve

Resources:
Identify water heater valves
Troubleshoot water pressure
Sharkbite pressure gauge
Sharkbite pressure gauge

Buy:
Sharkbite pressure gauge

Resources:
Water heater valves

Water heater circulation system

Buy:
Grundfos at Amazon

Resources:
How to install recirculation system
COLD side Sharkbite flexible water heater connector
COLD side Sharkbite flexible water heater connector

Buy:
Sharkbite water heater connection
Braided water heater line
Stainless steel flexible connection

Resources:
How to install electric water heater
How to install gas water heater
Leaking water heater
HOT side Sharkbite flexible water heater connector
HOT side Sharkbite flexible water heater connector

Buy:
Sharkbite water heater connection
Braided water heater line
Stainless steel flexible connection
Braided water heater line
Flexible water heater connection

Resources:
How to install electric water heater
How to install gas water heater
Leaking water heater
89T thermostat kit
Electric water heater thermostats
Thermostats stick melt and come out of calibration... replace thermostat
Symptoms: Cold water, uneven temperatures, reset tripping, TP releasing water
Buy:
Water heater thermostats at Amazon

Resources:
How to replace electric water heater thermostat
Add another thermostat to water heater
How to wire thermostats
Marathon water heater thermostats
Two water heaters
Troubleshoot electric water heater
Icon gas valve   
Gas water heater thermostats
If tank is overheating or not heating correctly, replace thermostat
Symptoms: Cold water, uneven temperatures, TP releasing water
Buy:
Gas water heater thermostats at Amazon

Resources:
How to replace gas water heater thermostat
Add another thermostat to water heater
Troubleshoot gas water heater
Expansion tankClosed system is caused by thermal expansion
Water heater causes expansion of water ....
Heating water causes volume of water to expand, water does not compress, so pressure builds up.
The pressure normally pushes back out onto the cold water line.
Check valves and incoming pressure reducing valves can create a closed system where dangerous pressure builds up inside the water lines due to the water heater...

A recirculation system and other plumbing installations sometimes cause the need for check valve.
The check valve stops the water from expanding back out into the cold water line.
Solution: install pressure reducing tank, or expansion tank anywhere on cold water line between tank and check valve ... the result: pressure from heated water expands into the expansion tank.

Buy:
Expansion tanks at Amazon

Resource:
Expansion Tank Installation pdf
Closed system / pdf
Thermal expansion
'The water in a water heating system expands when it is heated and has a greater volume. Since water does not compress like air, the expansion causes high pressure inside the water heater and plumbing system.

Thermal expansion, and the resulting high water pressure are a major consideration when designing water heaters and plumbing systems.
For example, residential water heating tanks are rated at 300 psi (when new), with 150 psi maximum safe operation.
The TP valve releases water pressure when pressure exceeds 150 psi .... but 150 psi poses a serious risk to older tanks that are rusted, and for plumbing pipes and fixtures in general. High pressure causes plumbing failures and early demise of heater.
Maximum incoming water pressure is 80 psi, with 50 psi recommended.
If pressure is above recommended, then a pressure reducing valve is installed, along with an expansion tank. The pressure-reducing valve and correctly-sized expansion tank are installed on incoming cold water line

Normal water heater operation will push the pressure back through the incoming cold water line, and out to the water main, or push pressure back into the water well tank.
Water expands approximately .00023% per degree F temperature rise.
In a normal system (not closed): ''Water expands approximately 2% in volume for a 100°F temperature rise (from 40°F to 140°F) ....40 gallon water heater, water being heated to its thermostat setting will end up expanding to about 40.53 gallons.'' This amount of thermal expansion, equal to about 1/2 gallon of water, can be easily absorbed back into the incoming cold water line.

In a closed system, the water expansion dynamic is much different.
If the incoming cold water line has a check valve at water meter, a pressure reducing valve (PRV), or sometimes a water softener can cause the problem, the pressure from thermal expansion will get backed up. The expanding water cannot be pushed out into the water main, and the pressure builds up because water doesn't compress.
For example, in a closed system where water is confined to a storage tank, a temperature rise of just 10°F (increasing from 75° to 85°F), increases pressure from 50 psi to 250 psi. This amount of pressure will quickly exceed the TP rating, causing water to be released in a series of short bursts, except when water is being used.' Troubleshoot TP valve

Symptoms of thermal expansion
•  ''Expulsion of water from TP. Effects are only noticeable after hot water use followed by periods of no water use.
• Relief valve drips during any recovery cycle when no hot or cold water is used.
• Hot water pipes creak while heater is recovering and all valves are closed.
• Tanks or other components of the water supply system fail prematurely.
• A metallic creaking noise might actually be heard in the location of the heater as the pressure is relieved and the stretched tank returns to a natural shape.
• Faucets drips during any recovery cycle when no hot or cold water is used.
• Water surges when a valve is first open and then pressure drops.''

''Periodic discharge of the temperature and pressure relief valve may be due to thermal expansion in a closed water supply system. The water utility supply meter may contain a check valve, backflow preventer or water pressure reducing valve. This will create a closed water system. During the heating cycle of the water heater, the water expands causing pressure inside the water heater to increase. The temperature and pressure relief valve may discharge hot water under these conditions which results in a loss of energy and a build-up of lime on the relief valve seat. To prevent this from happening, there are two recommendations:
1. Install a 125 PSI pressure relief valve in the cold water supply line. Make sure the discharge of this valve is directed to an open drain and
protected from freezing.
2. Install a diaphragm-type expansion tank that is suitable for potable water on the cold water supply line. The expansion tank must have a minimum capacity of 1.5 U.S. gallons for every 50 gallons of stored water.''

Tank pressureSteps to diagnose thermal expansion:
• ''Turn the heater thermostat all the way down, and install a water pressure gauge with dead hand (AOS part #4798) on the drain valve. Open the drain valve, so the gauge reads system pressure.
• Open a hot water tap and allow 15% to 20% of the tanks volume to run out. Shut off the drain valve and make sure that no other fixture in the system, hot or cold, is open. Make sure that outside fixtures, if they are on the same system, are turned off too. Any water leaks or use will make the test meaningless.
• Check the water pressure gauge, and turn the pointer so it lines up with the pressure indicating needle. Turn the thermostat back up to its normal position, so the heater cycles on. Watch the pressure gauge.
• If the system is closed, the pressure will start to climb steadily and rapidly. A small amount of thermal expansion control may be built into the system because of trapped air pockets or a water hammer arrestor. In that case the pressure will increase slightly, hold steady for a short time and then rapidly increase. The temperature and pressure relief valve (T&P) or PRV should open and release water once the pressure reaches the maximum setting on the valve. The valve will close once the pressure falls below the pressure setting of the valve.''
Buy:
Water pressure gauges
Watts telltale Pressure Gauge 276H300
Temperature pressure gauge

Telltale pressure gauge is left in place for a day, and marks the highest pressure so user can tell if there are pressure spikes that are causing TP valve to leak water, or other possible problems
Resource
Troubleshoot and identify water heater valves
TP valveTP valve / temperature-pressure valve
Mechanical 2 in 1 protection against excessive pressure and excessive temperature. TP valve will release water when conditions exceed TP valve rating, causing cold water to enter tank. This reduces both pressure and temperature. TP valve automatically closes when emergency conditions are over. Lift and gently lower TP valve once each year.
Residential water heaters are pressure tested to 300 pounds per square inch (PSI) and have a working pressure of 150 PSI.  T&P valve will open when the pressure inside the tank exceeds 150 PSI, allowing pressure to vent safely. T&P valve will open if water temperature at top of tank reaches 210°F depending on water heater, and TP valve rating. Commercial heaters can be rated for higher temperatures and pressures than typical residential heaters. TP valve must be rated for more BTU than tank rating so that release of temperature and pressure can outpace ability of tank to heat water.

Raise TP leverBuy: TP valves:
Replacement TP valves at Amazon
Teflon tape at Amazon
Resource:
How to troubleshoot and  replace TP valve
TP valve code
Reduce pressure with expansion tank
Expansion tankPressure over 80 psi can damage water heater and pipes over time.
150 PSI maximum allowable working pressure on residential water heater, but water pressure increases when heated.
Install expansion tank anywhere on cold water line, between any check valve or pressure reducing valve and water heater
Hot water will expand back into water line and then into expansion tank, preventing long-term damaging to pipes and fixtures and water heater

Closed system: Water confined to a storage tank or piping system, when subjected to a temperature rise of 10°F (increasing from 75° to 85°), increases pressure from 50 psi to 250 psi.
Normal system without check valves etc: Water expands approximately 2% in volume for a 100°F temperature rise (from 40°F to 140°F) ....40 gallon water heater, water being heated to its thermostat setting will end up expanding to about 40.53 gallons.

Buy:
Expansion tanks at Amazon

Resource:
Expansion Tank Installation pdf
Closed system / pdf
Pressure reducing valve Pressure reducing valve
High pressure over 80psi can damage water heater and plumbing
Install expansion tank, and/or pressure reducing valve
Pressure reducing valve is installed on cold water supply line to regulate and stabilize flow pressure

FYI: for a closed system: Water confined to a storage tank or piping system, when subjected to a temperature rise of 10°F (increasing from 75° to 85°), increases pressure from 50 psi to 250 psi ... Normal system without check valves etc: Water expands approximately 2% in volume for a 100°F temperature rise (from 40°F to 140°F)

Buy:
Pressure reducing valves
Pressure regulating valves at Amazon
Resource:
Watts pressure reducing valves/ pdf
Higher pressures change the boiling temperature. Water boils at 212°F – at sea level – unless the water is contained under pressure. At 52 psi gauge pressure, water would not boil until it exceeded 300° F. The TP valve would release hot water and cold water would enter tank to prevent steam explosion and tank rupture. Never cap off the TP valve if it is leaking.
Typical bath shower is 105°F. Setting thermostat to 120°F helps prevent thermal expansion, and shortened life or tank and plumbing from high pressure.
More chemicals are percolated out of water at high temperatures.
Water stored at 140°F in the tank may accumulate 19 lbs. of lime per year.
160°F in the tank may accumulate 85 lbs. of lime per year.
180°F in the tank may accumulate 135 lbs. of lime per year.
More gasses are separated as water temperatures rise. Air in water line
Support the economy:
Buy water heaters from my associate links:

50 gallon Gas water heaters at Amazon
40 gallon gas water heaters at Amazon
50 gallon Electric water heaters at Amazon
40 gallon electric water heaters at Amazon
Hybrid / heat pump/ water heaters at Amazon

Resources:
How to install gas water heater
How to install electric water heater
Troubleshoot gas water heater
Troubleshoot electric water heater
Point of use water heaters
Resources:
Troubleshoot Gas valves with manuals
Icon gas valve

How to replace water heater element Waste King disposal
How to wire tankless electric


Install point of use water heater
Titan tankless

Contactors/ relays
Type 1 and type 2 surge protection surge protection
Programmable timers

Woods timers
surge protection
Anode rods anode rods
Recirculation system

Tankless recirculation
Point of use water heater
Install and troubleshoot garbage disposal Waste King disposal
Buy
Electronic parts

Industrial supplies

Tools and home improvement

Home and garden

Hayward pool
Pentair pool

Southwire electric
Buy
Tools

DEWALT
Black and Decker
Stanley
SKIL
Makita
Porter-Cable
Bosch

Irwin Hand tools
Klein hand tools
Fluke electrical testing
Dremel hobby tools

Campbell Hausfeld air powered
Tekton automotive

Powerbuilt automotive
Saws and saw blades
box timers Resource:
Compare box timers
DPDT timers
Intermatic
Control water heater w/ Z-wave
Intermatic control centers Resource:
Intermatic control centers: and parts
Digital control centers and parts
Tork control centers and parts
Subpanels
All control centers and parts
Enclosures
programmable timer Resource:
Programmable timers
Countdown timers
Off delay timers
On delay timers
Timer modules
Din rail
Twin & one-shot
Woods
Intermatic
Tork
Low voltage power packs Recirculation systems
Buy from my affiliate links every time/ thanks:
Amazon
As an Amazon Associate I earn from qualifying purchases
Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission

E-mail: geno03245w@gmail.com
My response might end up in spam folder, check email folders
Waterheatertimer on Twitter
Message thru facebook