EJ500
Tork
ST01C  ST01C
Honeywell
Aube T1032
Aube
Westek TE06WHB
Woods 

Din rail
Intermatic EI500
Intermatic

Leviton

GE

Sylvania

Omron
24 volt timers
24 volt timers

Omron
3-phase timer
3-phase timer

Countdown
Westinghouse timers
Westinghouse
Woods 49028
Outdoor timers
Diehl timers
Diehl timers

Dayton
Westek timers
Westek

din rail timer Din rail timers and manuals
Home
Search waterheatertimer.org / all results
Search using Find button  

 Tweet button  
THC 15 timer
12-24-120 and 240 Volt AC
50/50 Hz 1 NO 1 NC
17 on-off each week

Buy:
THC 15 timers
THC 15 120 volt
THC15A 120 volt
THC15A 240 volt
12 V DC

Manual:
THC 15 manual
Sell sheet

How to wire THC 15 timer
Timer controls light bulb and contactor

Buy 2-Pole 40A contactor
120Volt coil
40 amp 240Volt coil
24 volt coil

Resource
Contactors
Select wire and breaker size
Reduce run-time of air conditioner.
Problem: air conditioner runs too much during peak electric prices. Programmable thermostat for the air conditioner can control peak usage by raising temperature and reducing hours of operation during peak times, but it cannot be programmed to limit actual number of run-time minutes per hour.

This diagram solves problem without compromising integrity of AC motor or equipment.

The din rail timer is programmed so timer is ON during peak hours. Any programmable timer will do the job but din rail timers are available in 24 volt, and also 120 and 240 volt models.

When the din rail  timer is OFF, it turns ON a twin timer.
When the din rail timer is ON, the twin timer is OFF.

One of the 24 volt wires from thermostat is connected to the com terminal on the din rail timer. When timer is ON, the 24 volt thermostat circuit is routed straight to the contactor for normal operation of air conditioner.

When the din rail timer is OFF, it switches the 24 volt thermostat wire away from contactor and to the Twin timer.
The twin timer is rated for either 24 volt (also available in 120 and 240V). Twin timer is designed to turn on-off-on-off-on-off in endless repeat cycle. ON times and OFF times are set independently, and can be any value between .01 second and 99.99 hours.
For example, the twin timer ON time can be set for 40 minutes. And OFF time set for 20 minutes. This limits the operation of air conditioner to 40 minutes.
During the 40 minute period, the twin time routes 24 volts to the air conditioner contactor for normal operation.

After 40 minutes, the twin timer cycles OFF, and then air conditioner cannot turn on for 20 minutes until the twin timer cycles back ON again. When the 20 minutes expires, the twin timer again lets the 24 volts complete circuit to contactor for 40 minutes.
The cycle of 40 ON and 20 OFF continues as long as din rail timer is ON. Set the din rail timer to turn ON during peak electric prices.

Illustration on right shows similar diagram except pulling power off the 240 volt AC circuit, and using a relay. When pulling power off the 240V air conditioner, use 10-15 amp inline fuse to protect timer and relay circuit. Use terminals to connect the smaller wires to contactor. Prevent loose connection and risk of fire: Do not put two different gauge wires under the screw plate on contactor. Never put stranded wire under screw plate.

Buy:
120-240 volt THC15 din rail timer
Uxcell DH48S-S twin timer
120 volt LY2 relay
240 volt relay
Relays with din rail

120-240 volt Twin timer

HVAC contactors
Inline fuse holders
Din rail fuse holder

Resources:
How to wire twin timer
Din rail timers and  manuals
Relays and contactors
Timer controls light bulb and 3-pole contactor
Resources:
3-pole Contactors
Select wire and breaker size
Geyser timer
Geyser, Onesto, Fatco, Bomain
Larger image
Geyser timer/ 230 volt 7-day
Same as Onesto and Fato on right

Manuals/ Resources:
Geyser timer sell sheet
Possible Geyser timer manual
How to wire timer
Fuse holder - timer - contactor
Din rail fuseholder

Buy:

Bomain contactor
4-pole contactor
10x38mm fuseholders
10 x 38 mm fuse

14x51mm fuseholder
14 x 51mm fuse
Timer controls LC1D 3-pole contactor
Buy
Contactor timer bundle
Motor control contactor
Din rail contactor
120 volt 7-day timer with 120 volt coil 30 amp contactor
240 volt timer
240 volt coil 32 amp contactor
Schneider contactor<
Motor contactors

Buy: fuseholder:
ANL fuseholder
Buy fuseholders at Amazon

Buy:
THC 15 timers
THC 15 120 volt
Buy:
THC 15 timers
kripal contactor
THC 15 120 volt
THC15A 120 volt
THC15A 240 volt
12 V DC

Manual:
THC 15 manual

Add 10 amp line fuse to wires that connect to timer.
Line fuse will protect 15 amp timer

Build your own 2 speed controller

Any Hp motor or pump

40 amp relay & contactor = 5 Hp @ 240 volt


Buy from my affiliate links:
Buy 40 amp contactor with 120 volt coil
40 Amp DPDT relay at Amazon
Magnecraft 50-1289-1 relay box and cover
Siemens power relays
Schneider W199 relay
NTE open frame relays
Packard DPDT fan relay
Tyco open frame relay
Contactors/ reliable for heavy amp loads
15 amp Relays for loads up to 10 amps
Resources:
How to assemble parts
Compare programmable timers
Wire size and amp charts for motors
Information on contactors


Busman fuseholder
Din-rail mount fuseholder
Busman panel mount line fuse holder

Fuse protects timer from overamperage
Timer has max rating 15 amps. To protect timer, install 5-10 amp fuse

Buy:
10x38mm din-rail mount fuseholders
10 x 38 mm fuse

14x51mm din rail mount fuseholder
14 x 51mm fuse
surface mount fuseholder
Buy:
Panel mount fuse holders at Amazon
ANL fuseholder
Fuse blocks at Amazon
Din rail fuseholder
10 x 38 mm fuse
Ceramic fuses at Amazon
Fast acting ceramic fuses
Electrical terminals
Solder guns

Resources:
Terminals/
Yellow for 12 gauge/ Blue for 14 gauge
Must solder solid copper wire when using fuseholder or terminal. Must solder stranded wire when using fuseholder. Stranded wire can be crimped to terminal.
How to solder wire to fuseholder or to terminals. Put wire in place. Place hot tip on wire. Wait for wire to heat. Touch solder to hot wire. Solder melts. Withdraw solder. Withdraw hot tip.
contactor Basic contactor wiring:
Pull out the disconnect so electricity is OFF. Open wiring compartment on air conditioner. Use terminals to connect the smaller wires to line side of contactor. A capacitor will be connected to Load side of contactor.
Use 10-15 amp inline fuse on one of the two wires to protect timer and relay circuit from 50-60 amp air conditioner circuit. The fuse will protect entire length of circuit.
Prevent loose connection and risk of fire: Do not put two different gauge wires under the screw plate on contactor. Never put stranded wire under screw plate.

Buy:
HVAC contactors
Inline fuse holders
Din rail fuse holder

Resources:
Relays and contactors

Larger image
Intermatic enclosure 9-3 ⁄8" x 5-1 ⁄2" x 3-5 ⁄8"
Nema 3R outdoor Enclosure:
Nema3R Enclosures can be used for outside installation:
Image on left shows din rail timer, din rail fuseholder, and 3 relays mounted on the rail.
Estimated height of twin timer on the rail is 4-1/2" tall.
Off-delay timers will fit in 3-5/8" space if mounted directly to metal box, and not din rail/ twin timer on the rail is 4-1/2" tall. The box on left: twin timer is too tall and would be attached to side of enclosure.
The control box circuit shown in image on left is used for outdoor lighting.
Bud Industries box
Buy:
2T511GA Intermatic
Nema3R enclosures
Hoffman 8 x 6 x 4 Nema 3R
Hoffman 6x6x6
Bud industries 11x7x5 box without knockouts
Din rail
Resource:
Compare enclosures
Twin timer wiring
Off delay wiring
Add several layers of control using twin timer, delay timer and 24-hour or 7-day timer
Image show test wiring

Buy
Din rails
THC 15 timer
AH3 delay timer
Indicator lights
Din rail fuseholder

Resources:
How to wire delay timer
How to wire din rail timers + manuals
THC 15 timer
120 volt, 7-program timer installed on din rail with two delay timers.
Photo taken during a test wiring.
When completed, the timer activates the delay timers that are wired to a twin timer (not shown). The circuit is used to control a Holiday light display that blinks in a cycle of different patterns.

Buy:
Din rails
THc15 timer
AH3 delay timer
Indicator lights

Resource:
How to wire delay timer
How to wire twin timer
MTD8 timer
MTD8 timer
Larger image
Image of buttons
Misc Manuals/ Resources:
MTD8 timer manual
How to wire timer
tddgt-manual.pdf
Onesto PST20A manual
Toptronic tddgt manual
Toptronic timer manual
Fato timers
Fato ACH15A manual
DCH15 timer manual
Talento 121 cycle timer
Larger image
Talento cycle timers

Buy:
Talento timers

Manuals/ Resources:
Intermatic cycle timers
How to wire Din Rail timers
Talento 882 timer
Larger image
Talento programmable timers


Manuals/ Resources:
Intermatic Talento 1-4 channel tim
Intermatic Din Rail timersers
How to wire Din Rail timers
T80 timer
T80 timer
230Volt SPST

Buy:
T80 timer

Manuals/ Resources:
T80 timer manual
How to wire T80 timer
Legrand 03740 timer manual
How to wire Din Rail timers
More brands din rail timers:

Resources/ links:
How to wire Din Rail timers

Intermatic Din Rail timers
Tork Din Rail series
Hagar Din Rail series

Legrand 03700 timer and manual
din rail mount MIB-DIN
Din Rail
Buy:
4" long 22-00012 din rail
Din rail
Resources:
Intermatic trippers and parts
legrand 412631
Legrand 412641 2-channel timer
Legrand 412641 timer manual
Legrand 04761 timer
Legrand manual image
Generally, the instructions are shown below: you will have to fiddle around to tweak the instructions since this model Legrand is discontinued, and replaced with the 412641
There are 4 programming buttons located on face of timer: menu, on, +, -
Press menu, use +- to scroll down to GCFEIL, Press on, select language
Press menu, use +- to scroll down to set, press on, set current time and date using same basic commands.
Press menu, use +- to scroll down to program, press on, select new, press on, select day-days of operation for program 1, select individual, set On and OFF times for program 1, save
Press menu, use +- to scroll to function, select auto to run programs.

Larger image
Tork: DIN

DIN series Panel/Rail mount
7-day 1 or 2 channel 120 volt
Tork DIN series sell sheet
DIN 101B DIN201B programming
DIN 100 install and operation
Din 100A operating
DIN 100A 101B 201B wiring
DIN series dimensions
DIN series sell sheet
DIN 100A SPDT 120V 1 channel
DIN 101B SPDT 120V 1 channel*
DIN 201B SPDT 120V 2 channel*
*Pulse and cycling
More DIN Rail timers:
Hagar DIN rail timers
Intermatic DIN rail timers
Onesto timer
Fato timer
Legrand 03700 timer and manual

Hagar EG010
Hagar timers and manual


Incoming power has two wires... connect these wires to terminals 5 and 6... and this will cause timer to operate and keep time.

Run a jumper wire between terminal 6 and COM terminal 2


Load (light bulb, contactor, etc) has two wires: connect one wire to terminal 5 and other wire to terminal 3

Terminal 1 is ON when timer is OFF.
It is the NC or normally-closed terminal.
Timer controls light bulb and 3-pole contactor

Resources:
3-pole Contactors
Select wire and breaker size
Fuseholders
Support the economy:
Buy water heaters from my associate links:

50 gallon Gas water heaters at Amazon
40 gallon gas water heaters at Amazon
50 gallon Electric water heaters at Amazon
40 gallon electric water heaters at Amazon
Hybrid / heat pump/ water heaters at Amazon

Resources:
How to install gas water heater
How to install electric water heater
Troubleshoot gas water heater
Troubleshoot electric water heater
Point of use water heaters
Resources:
Troubleshoot Gas valves with manuals
Icon gas valve

How to replace water heater element Waste King disposal
How to wire tankless electric


Install point of use water heater
Titan tankless

Contactors/ relays
Install and troubleshoot garbage disposal Waste King disposal
Programmable timers

Woods timers
surge protection
Anode rods anode rods
Recirculation system

Tankless recirculation
Point of use water heater
Type 1 and type 2 surge protection surge protection
Buy
Industrial electric

Industrial supplies

Tools and home improvement

Home and garden

Hayward pool
Pentair pool

Southwire electric
Buy
Tools

DEWALT
Black and Decker
Stanley
SKIL
Makita
Porter-Cable
Bosch

Irwin Hand tools
Klein hand tools
Fluke electrical testing
Dremel hobby tools

Campbell Hausfeld air powered
Tekton automotive

Powerbuilt automotive
Saws and saw blades
box timers Resource:
Compare box timers
DPDT timers
Intermatic
Control water heater w/ Z-wave
Intermatic control centers Resource:
Intermatic control centers: and parts
Digital control centers and parts
Tork control centers and parts
Subpanels
All control centers and parts
Enclosures
programmable timer Resource:
Programmable timers
Countdown timers
Off delay timers
On delay timers
Timer modules
Din rail
Twin & one-shot
Woods
Intermatic
Tork
Low voltage power packs Recirculation systems
Buy from my affiliate links every time/ thanks:
Amazon
As an Amazon Associate I earn from qualifying purchases
Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission

E-mail: geno03245w@gmail.com
My response might end up in spam folder, check email folders
Waterheatertimer on Twitter
Message thru facebook