to wire Intermatic PF1112 freeze control How to wire PF1202T How to wire PF1222TB1 How to wire control center |
PF1112T Larger image |
PF1112T/
freeze control / plus one
T104M 240Volt mechanism/ 3 Hp/ 40 amp timer Knock outs for GFCI outlet/ or switches Buy control center: PF1112T panel/ no breaker slots, 1 timer at Amazon Resources Sell sheet with dimensions/ pdf Sell sheet with models Parts sheet /pdf PF1112 manual Wiring illustration for PF1112T freeze control and T104 timer Buy parts Freeze replacement at Amazon PF1102M 240Volt freeze replacement with relay Add fireman switch to timer/ from Amazon Trippers156T1948A set at Amazon (dial hold up to 12 on and 12 off trippers) Replace clock motor: WG1573 208-277V Amazon Buy T104M clock mechanism at Amazon Buy T104M201 clock mechanism with fireman switch at Amazon |
PF1112T
wiring Large image of wiring The PF1112T has one T104 240 volt timer, plus freeze control thermostat, and relay. The relay is necessary to handle 40 amp capacity same as T104 timer. The thermostat can be purchased separately to replace one that is no longer functioning. Thermostat is not rated for 40 amps. Buy Intermatic replacement thermosat The thermostat is mechanical bi-metal switch that reads approximate temperatures. Thermostat activates when temperature falls below set point. This activates the relay. The relay closes (turns ON) two circuits that override timer. If the timer is ON, the 240 volt pump will stay ON. If the timer is OFF, the pumps will turn ON and stay on until temperature rises above thermostat set point. 240 volt enters control panel with 2 Hot wires. Hot wire 1 connects to terminal 1 and a jumper wire runs from terminal 1 on timer to contact 1 on relay. A wire runs from contact 1 on relay to the freeze thermostat. Hot wire 2 connects to terminal 3 and a jumper wire runs from terminal 3 on timer to contact 3 on relay. A wire runs from contact 3 to the relay coil. Another wire runs from the other side of the relay coil to thermostat. The pump connects to terminal 2 and terminal 4 on the T104 timer. A jumper wire runs from terminal 2 to contact 2 on relay. A jumper wire runs from terminal 4 to contact 4 on relay. |
PF1202T Larger image |
PF1202T/
freeze control / plus two
T104M 240Volt mechanism/ 3 Hp/ 2-40 amp timers Knock outs for GFCI outlet/ or switches Buy control center: PF1202 freeze control panel / no breaker slots/ plus 2 timers At Amazon Buy parts PA102 thermostat and relay Freeze thermostat replacement at Amazon Freeze control relay 143T135 at Amazon Add fireman switch from Amazon Trippers156T1948A set at Amazon (dial hold up to 12 on and 12 off trippers) Replace clock motor: WG1573 208-277V Amazon Buy T104M clock mechanism at Amazon Buy T104M201 clock mechanism with fireman switch at Amazon Resources Sell sheet with dimensions/ pdf Sell sheet with models Parts sheet /pdf Parts sheet 2 PF1202 manual PF1202T manual Intermatic pool parts catalog/ pdf |
PF1202T Larger image |
PF1202T/
freeze control / plus two
T104M 240Volt mechanism/ 3 Hp/ 2-40 amp timers Knock outs for GFCI outlet/ or switches Buy control center: PF1202 freeze control panel / no breaker slots/ plus 2 timers At Amazon Buy parts PA102 thermostat and relay Freeze thermostat replacement at Amazon Freeze control relay 143T135 at Amazon Add fireman switch from Amazon Trippers156T1948A set at Amazon (dial hold up to 12 on and 12 off trippers) Replace clock motor: WG1573 208-277V Amazon Buy T104M clock mechanism at Amazon Buy T104M201 clock mechanism with fireman switch at Amazon Resources Sell sheet with dimensions/ pdf Sell sheet with models Parts sheet /pdf Parts sheet 2 PF1202 manual PF1202T manual Intermatic pool parts catalog/ pdf |
How to wire freeze thermostat PF1202T wiring PF1222TB wiring How to wire PF1202T and PF1222TB Your incoming 240 volt connects to terminals 1 and 3 on FILTER timer.... Clock motors for both timers MUST connect to live 240 volt. This means clock motor on CLEANER timer must connect to terminals 1 and 3 on FILTER timer, or to a team block where 240 volt arrives inside the control center. This wiring ensures that both clock motors are running at all times, and both yellow dials are rotating once per day. On a control center WITHOUT freeze override, terminals 1 and 3 on CLEANER timer connect to terminals 2 and 4 on FILTER timer .... this means CLEANER can only turn ON when FILTER pump is ON... On a control center WITH freeze override, terminals 1 and 3 on CLEANER timer connect to the freeze control as illustrated, and then connected to terminals 2 and 4 on FILTER timer .... this means CLEANER can only turn ON when FILTER pump is ON, same as control center without freeze. The freeze override will send power to the Cleaner timer when temperatures drop below thermostat set point |
Larger image |
How to wire PF1120 T104 timer connected to PF1102 Freeze thermostat and relay Freeze control by-pass timer and turns pump On when temperature drops below freezing. Resources: How to wire T104 |
178T24 stand-alone 15 amp
Thermostat PA102 thermostat and 40 amp relay Buy PA102 mechanical thermostat and SPDT relay 178T24 Amazon Freeze thermostat Resources 178T24 wiring How to wire |
Override
switch with 178T24 freeze control Up to 30 amp Freeze control override switch Buy: Leviton 3032 30 amp switch at Amazon Leviton 30 amp switch at Amazon 30 amp switches at Amazon< |
Keep wires straight Use solid copper wire If wiring terminal or end of wire are covered with green, use emery board to clean terminal and sandpaper to clean wire. |
Larger image |
Both wires MUST be same
gauge Straighten each wire If wire is corroded or overheated, clean the end with sandpaper and wipe with cloth. If wire has been melted, cut back and reattach, or replace wire. Tighten screw very tight against copper wire |
|
Use wire connector |
Use push-on wire connectors |
3
wires/ or different gauge wires Join wires with wire connector or push-on connector Run jumper to screw terminal. Buy: Push on wire connectors at Amazon Red 3P connector (shown) for 10-14 gauge wire Connector assortment Resource: How to select and install wire connector |
Fire safety/ Do not put stranded
wire under screw plate Do not install stranded wire under screw. Problem1: picture shows 2 different gauge wires under screw plate Problem2: Stranded wire will expand and contract and come loose under screw plate, even if it is the only wire under the screw plate Attach stranded wire and solid wire with wire connector, and run solid copper jumper wire to screw terminal Take photo of wires before starting. Resources: Timer caught fire Load ratings for Intermatic timers/ pdf |
||
Larger image |
12 Ga |
10 gauge or 12 gauge? Compare your wire with short pieces of 10 and 12 gauge wire from local box store 10 gauge for 30 amp breaker. 10 gauge wire can have black-white and sometimes black-red 12 gauge for 20 amp breaker 12 gauge will have black and white wires . Resources: Match color code and amp rating for wire Basic house wiring |
Add black tape when White wire
carries voltage (applies to 208 and 240V
circuits) With 120 and 277 Volt circuits, White wire is Neutral, and Black is Hot With 208 and 240 circuits, both wires are Hot, and both wires carry voltage Black tape on White wire identifies wire is Hot and not Neutral |
Buy Electronic parts Industrial supplies Tools and home improvement Home and garden Hayward pool Pentair pool Southwire electric |
|
Buy
Tools DEWALT Black and Decker Stanley SKIL Makita Porter-Cable Bosch Irwin Hand tools Klein hand tools Fluke electrical testing Dremel hobby tools Campbell Hausfeld air powered Tekton automotive Powerbuilt automotive Saws and saw blades |
|
Resource: Compare box timers DPDT timers Intermatic Control water heater w/ Z-wave |
|
Resource: Intermatic control centers: and parts Digital control centers and parts Tork control centers and parts Subpanels All control centers and parts Enclosures |
|
Resource: Programmable timers Countdown timers Off delay timers On delay timers Timer modules Din rail Twin & one-shot Woods Intermatic Tork |
|
Recirculation systems |
Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |