EJ500 timer

Larger image
EJ500 Manual
EJ500
Battery operated, no neutral wire required
Astronomic dawn-dusk or programmable
6 ON and 6 OFF settings per week
Incandescent light bulbs only, single-pole or 3-way
USE ST01C or Ei600 for halogen and CFL
Buy:
EJ500 timer at Amazon
Intermatic ST01c timer/ 1 year warranty
ST01a almond
Intermatic ST01K combination timer
LR44 battery at amazon
AG13 LR44 at Amazon
Batteries at Amazon

Resources:
EJ500 manual
Sell sheet
How to wire EJ500 timer diagrams
CFL bulb    
Not rated for CFL, LED etc.
EJ500 is For incandescent (Tungsten) loads only
For CFL, motors. contactors etc choose EJ600, ST01, Ei600 timers:
Buy:
EJ600 at Amazon
Intermatic ST01c timer/ 1 year warranty
ST01a almond
Intermatic ST01K combination timer
Ei600 timer at Amazon
CFL bulbs at Amazon
Resources:
Manuals and ratings for each above timers
EJ500 timer
Not rated for following loads

    * Compact Florescent
    * Energy Saver
    * Flood lights
    * Halogen
    * Mercury Vapor
    * Christmas lights
    * Candelabra bulbs

Do NOT connect EJ500 to following loads:

    * Outlets
    * Socket Adapters
    * Pumps
    * Fans
    * Contactors
    * Relays
    * Appliances
    * Towel warmers
    * Anything besides standard base incandescent light bulbs
    *
Intermatic EJ500 buttons
See Larger

Reset timer to restore functionality
How to reset timer
Press and hold Next button.
Press and release Reset button
Keep holding Next button down until display changes
Release Next button and display should flash 12:00
Reprogram timer

Timer retains memeories until reset.

Timer has 1 year limited warranty
Use Ei600 timer for 5 year limited warranty

Battery compartment located below buttons
Pry out with small screwdriver
EJ500 takes two LR44/SR44 batteries
Error NoOP = replace batteries
Reset timer
Reprogram

Resources
EJ500 Manual
EJ500 wiring Single pole wiring
Single pole switch has 2 wires plus bare copper ground wire.
Timer works for Incandescent light bubs up to 600 watts
No underground wiring
Maximum distance 100' (Most inwall timers have same distance limit)
No neutral wire needed
Single pole switch has two wires + plus bare ground wire.
One of the wires connected to switch will be Hot wire.
Connect Timer Black to Hot wire
Connect Timer Blue to other wire (Load wire).
Connect bare copper wire to ground wire.
Cap Timer Red wire.
Timer Red is only used in 3-way wiring

Turn power ON.
Press timer door like a push-button switch.
If light turns ON-OFF then timer is wired correctly
If light does not turn ON-OFF, then reverse timer blue and black wires.

Troubleshoot wiring:
Reverse blue and black wires.
Make sure red is capped.
Make sure bulb works
Check circuit breaker
Check wire nuts are tight against both wires
EJ500 wiring Single pole with only 2 wires in box
Follow same instructions above

Timer Red wire
Timer Red is only used for 3-way switching .... but it can be used another way.
Connect Timer Red and Timer Blue if youn want dawn-to-dusk operation instead dusk-to dawn
3-way switch wiring
Common screw is dark-colored
Traveler-screws are brass colored
Line side connects to line from breaker
Load side connects to light
3-way switch
Timer replaces one 3-way switch
Other 3-way must be rewired
Identify wire that connects to common screw
Usually the dark-colored screw
1) Take photo of wires before disconnecting old switch.
2) Note which wire connects to dark-colored screw
3) If screws are not color-coded: Look on back of old switch to see which screw is marked common, and then mark that wire as common.

Common wire will connect to Timer Black wire, or Timer Blue wire.
Wire EJ500 timer
Larger image

With timer on Load side: if electricity goes OFF, then timer will start to click on-off using the battery. If this happens, click the 3-way switch up or down. Afterwards, the timer will no longer click on-off.

If power remains off for a while, the current time must be re-programmed. However the scheduled programs are not affected by power outage and remain in memory forever until timer is manually reset.
3-way / Timer on Load side
Timer on Load side
Blue wire connects to wire that was connected to common screw
Timer black wire must always be connected to Hot
Blue wire must always go to Load
When power is applied to red wire, the timer programming reverses.

Remember, the remaining 3-way switch has to be rewired as if it was ordinary on-off switch using common screw and one traveller screw.
When the switch is turned ON-OFF, it reverses timer programming.
Wire EJ500 timer
Larger image
3-way / Timer on Line side
Timer on Line side
Black wire connects to screw that was connected to common screw
Timer black wire must always be connected to Hot
Blue wire must always go to Load
When power is applied to red wire, the timer programming reverses.

Remember, the remaining 3-way switch has to be rewired as if it was ordinary on-off switch using common screw and one traveller screw.
When the switch is turned ON-OFF, it reverses timer programming.
Resources
Basic house wiring
Color code for wire
ST01C timer controls 240Volt water heater Use ST01C or Ei600 to control any voltage Load
EJ500 is for incandescent oly.
Use ST01c for any type Load, and any voltage circuit
Example shows ST01C connected to 240Volt line
Buy:
Intermatic ST01c timer at Amazon
Intermatic ST01K combination timer
CR2 replacement battery at Amazon
CFL bulbs at Amazon
Manuals/ resources:
ST01C manual
Sell sheet with model numbers
How to program ST01c and Ei600 timers
How to wire ST01C and Ei600 timer diagrams
Control any 240volt load with ST01c or Ei600 timer
Contactors
GFCI 240Volt GFCI and T104 timer
How to wire GFCI
How to wire T104 timer
Intermatic timers and manuals

T104 timer
Support the economy:
Buy water heaters from my associate links:

50 gallon Gas water heaters at Amazon
40 gallon gas water heaters at Amazon
50 gallon Electric water heaters at Amazon
40 gallon electric water heaters at Amazon
Hybrid / heat pump/ water heaters at Amazon

Resources:
How to install gas water heater
How to install electric water heater
Troubleshoot gas water heater
Troubleshoot electric water heater
Point of use water heaters
Resources:
Troubleshoot Gas valves with manuals
Icon gas valve

How to replace water heater element Waste King disposal
How to wire tankless electric


Install point of use water heater
Titan tankless

Contactors/ relays
Type 1 and type 2 surge protection surge protection
Programmable timers

Woods timers
surge protection
Anode rods anode rods
Recirculation system

Tankless recirculation
Point of use water heater
Install and troubleshoot garbage disposal Waste King disposal
Buy
Electronic parts

Industrial supplies

Tools and home improvement

Home and garden

Hayward pool
Pentair pool

Southwire electric
Buy
Tools

DEWALT
Black and Decker
Stanley
SKIL
Makita
Porter-Cable
Bosch

Irwin Hand tools
Klein hand tools
Fluke electrical testing
Dremel hobby tools

Campbell Hausfeld air powered
Tekton automotive

Powerbuilt automotive
Saws and saw blades
box timers Resource:
Compare box timers
DPDT timers
Intermatic
Control water heater w/ Z-wave
Intermatic control centers Resource:
Intermatic control centers: and parts
Digital control centers and parts
Tork control centers and parts
Subpanels
All control centers and parts
Enclosures
programmable timer Resource:
Programmable timers
Countdown timers
Off delay timers
On delay timers
Timer modules
Din rail
Twin & one-shot
Woods
Intermatic
Tork
Low voltage power packs Recirculation systems
Buy from my affiliate links every time/ thanks:
Amazon
As an Amazon Associate I earn from qualifying purchases
Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission

E-mail: geno03245w@gmail.com
My response might end up in spam folder, check email folders
Waterheatertimer on Twitter
Message thru facebook