Pin timer modes |
AH3-3 delay timer and base 12-24-120-240 volt off delay timer/ 0-60 minutes Buy: 120 volt AH3-3 at Amazon Resources: How to wire AH3-3 timer How to wire H3CR timer |
ICM 102 on-delay timer 0 Hp Must use contactor 24/ 120-240 volt AC .03-10 minutes Buy: ICM 102 Dayton off delay timers Resource: Use off delay to control motors |
Off-delay timer/ 19-240 volt AC 15-300 seconds Buy Dayton off delay timers Resource: How to wire Dayton off delay timer |
12-24-120-240 volt digital twin timer 1 second to 99 minutes Buy Uxcell DH48S-S twin timer Resource: DH48S twin timer manual Override air conditioner with timer |
12-24-120-240 volt digital off delay/ twin timer .01 second to 99.99 hours Buy: Twin timers at Amazon Omron twin timers 24 volt twin timer Resource: How to wire twin timers |
Delay
on Make Application of input voltage to timer starts the time delay. At the end of the time delay the load is energized. To reset, remove input voltage from timer. Buy: Sestos relay timer Migro assorted timer |
|
Delay
on Break Input voltage is applied continuously. Upon closure of the initiate switch the load is energized and remains energized as long as the switch is closed. When the initiate switch opens, the load remains energized and the time delay is started. At the end of the time delay the load is de-energized and the timer is ready for another cycle. |
|
Single
Shot Input voltage is applied continuously. Upon closure of the initiate switch the load is energized and the time delay is started. At the end of the time delay the load is de-energized and the timer is ready for another cycle. Maintained closure of the initiate switch will not affect the time delay period. |
|
Interval
Replace the initiate switch with a permanent electrical connection between terminals 1 and 2. Application of input voltage to the timer energizes the load and starts the time delay. At the end of the time delay the load is de-energized. To reset, remove the input voltage from the timer. |
|
Resettable
Single Shot / Watchdog Power is applied and load turns on for specigfied time. When power is turned off and on, the load turns on gfor a specified time. Or Input voltage is applied continuously. Upon closure of the initiate switch the load is energized for a specified amount of time. Maintained closure of the initiate switch will not affect the time delay period. When the initiate switch is opened and re-closed while the load is energized the time delay is re-started. At the end of the time delay the load is de-energized and the timer is ready for another cycle. |
|
One
shot.... .... input
signal from switch or resistor-circuit turns timer On for specified
period of
time... you set period of time when timer turns Off. Timer awaits next
input signal, and then repeats same sequence. On delay.... input signal from switch or resistor-circuit activates delay period... when delay expires, timer turns ON... you set duration of delay. Timer awaits next input signal, and then repeats same sequence. Delay terminates when power is off. Off delay.... input signal from switch or resistor-circuit turns timer ON for duration of delay... when delay expires, timer turns Off... you set duration of delay. Timer awaits next input signal, and then repeats same sequence. If power is interrupted then reapplied, the the delay starts over. Twin timer or cycler ... continuous repeated cycle of on-off ... you set duration for On and duration for Off. On and Off periods can be different length. Once timer is set, then it repeats on-off cycle without variation. Timer can run continuously, or stopped when power to timer is switched Off. Pulse generator ... when power is applied, a wait period begins followed by load on for specified time. After specified time, the load turns off. |
|
Resources: How to wire AH3 How to wire off delay Woods-timers-and-manuals.html#Omron How-to-wire-pin-timers.html |
Buy Electronic parts Industrial supplies Tools and home improvement Home and garden Hayward pool Pentair pool Southwire electric |
|
Buy
Tools DEWALT Black and Decker Stanley SKIL Makita Porter-Cable Bosch Irwin Hand tools Klein hand tools Fluke electrical testing Dremel hobby tools Campbell Hausfeld air powered Tekton automotive Powerbuilt automotive Saws and saw blades |
|
Resource: Compare box timers DPDT timers Intermatic Control water heater w/ Z-wave |
|
Resource: Intermatic control centers: and parts Digital control centers and parts Tork control centers and parts Subpanels All control centers and parts Enclosures |
|
Resource: Programmable timers Countdown timers Off delay timers On delay timers Timer modules Din rail Twin & one-shot Woods Intermatic Tork |
|
Recirculation systems |
Enter Amazon from
my links Amazon E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter |