Burned R1 Resistor


Multimeter

Test for breaks in wire/ Test for voltage
Most appliance require 80% rated voltage to function correctly
Buy
Multimeters at Amazon
Electric testers at Amazon
Resource:
How to test and replace element
How to test thermocouple
Element tests for 120 volts
How to test wire
Safety when testing wires:
Never touch wet or previously flooded appliance.
Never stand on wet surface when working on electric.
Never stand on bare soil, put down dry boards.
Tape tester leads to wood sticks to keep hands away from power.
Use non-contact voltage tester before touching wires.
Never touch or lean into any made of metal.
Remove metal objects from pockets.
Do not use oxygen or fuel accelerants in same room as electrical repairs

Resource:
Basic house wiring

Non-contact voltage tester

Test for power without touching connectors
NEVER assume power is OFF
Buy:
Non-contact voltage tester Amazon
Electric testers at Amazon
Resource:
How to test electric power is off
wire connector assortment

Twist-on wire connector assortments

Do not reuse old connectors
Buy:
Connector assortment at Amazon
Connector assortment at Amazon
Resource
How to select and install twist-on wire connectors
Weatherproof wire connector

Weatherproof wire connector

Connector cavity is full of silicone
Built-in cover keeps silicone in place
Protect from water, dust etc
Buy from my affiliate links
Weatherproof size 14 to 6 Amazon
Weatherproof size 22 to 8 Amazon

Resource
How to select and install connectors
Wire connector wrench
Wrench to apply wire connectors
Tighten connector

Buy:
Wire connector blaster
Twist connector wrenches at Amazon

Resources:
How to twist wire
How to select and install twist-on wire connectors

Buy:
Blue for 16-14 wire
Yellow for 12-10 wire

Resource:
How to install terminals
Treminals

Terminals

Buy:
Terminal kit
Blue for 16-14 wire
Yellow for 12-10 wire
Push on wire connectors

Push-on wire connectors in place of twist-on connectors

Buy:
Push on wire connectors Amazon
Red 3P connector for 10-14 gauge wire
Lever connectors for stranded wire at Amazon
remove cable staple
Buy
End cutting nippers at Amazon

 
linesman pliers
When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistances on wire and creates weak point.
Buy tools:
Wire strippers at Amazon
Linesman pliers
Utility knife at Amazon
End cutting nippers at Amazon

Use solid copper wire
Fire inside timer caused by stranded wire
Keep enclosure door closed at all times
Buy:
soldering guns
Resource

Timer caught fire
GE 15136 timer
Buy 24 hour:
GE 15135 24-hour/ 40 amp/ outdoor metal box

56922 plastic box at Amazon

Resources:
15207 Manual
Quick-start guide to wiring

More GE timers and manuals
GE 15136 timer
Buy 24 hour or 7-day:
GE 15136/ 7 day/ 7 programs /40 amp/ outdoor metal box

Resources:
GE 15132 manual
How to wire GE 15136
More GE timers and manuals
Woods 59402 timer
Buy 24 hour:
Woods 59402 timer

Resources:
59401 and 59402 manual
59402 sell sheet

More Woods timers
Tork DTU water heater timer
Larger image
Permanent ON-OFF override

Buy 24 hour/ or 7-day
DTU40 At Amazon

Resources:
DTU40 instruction manual
Sell sheet with model numbers
GM40 timer
GM40 series
7-day and 24 hour

Resources:
GM 40 series timers with same wiring
Compare all box timers
water heater timer
Resources:
Intermatic 24 hour timers
Tork box timers
Compare all box timers
R1 and R2 resistors are a failure point on the timers shown above.
You can identify the problem by looking at the base of the resistors located on upper left corner on front of timer circuit board.
There will be a slight burned spot at the point where these resistors are soldered.
When this point is burned, there is no recovery.
Test the relays. Some timer functions might still operate.
For example, one fellow discovered that one-of-the-two relays still worked.
Note: 240 volt can be turned on-off with one relay.
The relays K1 and K2 from the GM40 may have different coil resistances, affecting the transfer efficiency on R1 and R2, causing them to overheat, due to relay supplier.
R1 resistor
Larger image

Unburned R1 R2 resistors

Note there is no high-heat or burn residue at end of each part
burned resistor

Burned R1 resistor on timer

R1 resistor burned, R2 resistor burned

Look at burned spot where the resistor is soldered.
This is a problem as timer ages.

Normally if R1 or R2 are burned... look carefully and other nearby parts have signs of burning also.
R1-R2 are usually first place you see overheat problem
but you can see that 4 resistors located on left side of dial and 3 resistors on right side have evidence of burned point at the solder joint.

No prevention steps. Check that timer is receiving correct voltage and Load does not exceed rating.
Solutions:
Replace timer and Check if one of the relays function... sometimes a timer can be used with one relay.
In this case, it was an older-model defrost timer with several methods for wiring. We were able to get 1 relay to work, and the timer was used.

Frequently these timers with burned R1 are sold on ebay after they have been removed from service... simply because the timer looks good or repair seems simple.

Related solutions:
Use correct voltage to match timer
Do not exceed load rating on timer
Use correct wire and breaker


Resources:
Match breaker and wire size

Figure volts amps watts
Compare similar timers
Compare all box timers
GM series defrost timers
burned resistor on timer
Larger image
Keep wires straight
Use solid copper wire
If wiring terminal or end of wire are covered with green, use emery board to clean terminal and sandpaper to clean wire.
Insdulation under screw plate
Larger image
Both wires MUST be same gauge
Straighten each wire
If wire is corroded or overheated, clean the end with sandpaper and wipe with cloth.
If wire has been melted, cut back and reattach, or replace wire.
Tighten screw very tight against copper wire

Use wire connector  
Push on wire connectors
Use push-on wire connectors
3 wires/ or different gauge wires
Join wires with wire connector or push-on connector
Run jumper to screw terminal.
Buy:
Push on wire connectors at Amazon
Red 3P connector (shown) for 10-14 gauge wire
Connector assortment
Resource:
How to select and install wire connector
Fire safety/ Do not put stranded wire under screw plate
Do not install stranded wire under screw.
Problem1: picture shows 2 different gauge wires under screw plate
Problem2: Stranded wire will expand and contract and come loose under screw plate, even if it is the only wire under the screw plate
Attach stranded wire and solid wire with wire connector, and run solid copper jumper wire to screw terminal
Take photo of wires before starting.

Resources:
Timer caught fire
Load ratings for Intermatic timers/ pdf


Larger image
10-3-wire
10-3-wire  12 Ga
10 gauge or 12 gauge?
Compare your wire with short pieces of 10 and 12 gauge wire from local box store

10 gauge for 30 amp breaker.
10 gauge wire can have black-white and sometimes black-red

12 gauge for 20 amp breaker
12 gauge will have black and white wires
.
Resources:
Match color code and amp rating for wire
Basic house wiring
Add black tape when White wire carries voltage (applies to 208 and 240V circuits)
With 120 and 277 Volt circuits, White wire is Neutral, and Black is Hot
With 208 and 240 circuits, both wires are Hot, and both wires carry voltage
Black tape on White wire identifies wire is Hot and not Neutral
Support the economy:
Buy water heaters from my associate links:

50 gallon Gas water heaters at Amazon
40 gallon gas water heaters at Amazon
50 gallon Electric water heaters at Amazon
40 gallon electric water heaters at Amazon
Hybrid / heat pump/ water heaters at Amazon

Resources:
How to install gas water heater
How to install electric water heater
Troubleshoot gas water heater
Troubleshoot electric water heater
Point of use water heaters
Resources:
Troubleshoot Gas valves with manuals
Icon gas valve

How to replace water heater element Waste King disposal
How to wire tankless electric


Install point of use water heater
Titan tankless

Contactors/ relays
Type 1 and type 2 surge protection surge protection
Programmable timers

Woods timers
surge protection
Anode rods anode rods
Recirculation system

Tankless recirculation
Point of use water heater
Install and troubleshoot garbage disposal Waste King disposal
Buy
Electronic parts

Industrial supplies

Tools and home improvement

Home and garden

Hayward pool
Pentair pool

Southwire electric
Buy
Tools

DEWALT
Black and Decker
Stanley
SKIL
Makita
Porter-Cable
Bosch

Irwin Hand tools
Klein hand tools
Fluke electrical testing
Dremel hobby tools

Campbell Hausfeld air powered
Tekton automotive

Powerbuilt automotive
Saws and saw blades
box timers Resource:
Compare box timers
DPDT timers
Intermatic
Control water heater w/ Z-wave
Intermatic control centers Resource:
Intermatic control centers: and parts
Digital control centers and parts
Tork control centers and parts
Subpanels
All control centers and parts
Enclosures
programmable timer Resource:
Programmable timers
Countdown timers
Off delay timers
On delay timers
Timer modules
Din rail
Twin & one-shot
Woods
Intermatic
Tork
Low voltage power packs Recirculation systems
Enter Amazon from my links
Amazon

E-mail: geno03245w@gmail.com
My response might end up in spam folder, check email folders
Waterheatertimer on Twitter