Search waterheatertimer.org
/
all results
|
How
to wire GM40
GM40AV
GM40AVE WHQ series Including all brands of 40 amp DPDT timers/ each has indoor-outdoor Nema 3R enclosure Each rated 120-240-277 volt Applies to Intermatic, GE, Tork |
Larger image Permanent ON-OFF override |
GM40AV
40 amp 120V-208V-240V-277V Automatically detects voltage 24 hour, 15 minute intervals Power outage backup option Buy: GM40AV 120-208-240-277V at Amazon GM40AVQ w/ back-up battery at Amazon GM40 40 amp 120V-208V-240V-277V Dip switches to select voltage 7-day with 15 minute intervals or 24 hour with 1.75 hour intervals Buy Buy GM40 24 hour at Amazon WHQ4 120-208-240-277Volt 24-hour at Amazon Manuals/ Resource: GM40AV Manual GM40AV sell sheet GM40 instruction manual Sell sheet with model numbers How to set analog timers Intermatic timers and manuals |
Larger image
Permanent ON-OFF override |
GM40AVE digital 40 amp 120V-208V-240V-277V Automatically detects voltage 7-day programmable, 20 on 20 off set points Power outage backup Buy: GM40AVE 120-208-240-277Volt GM40AVE at Intermatic Manuals/Resources: GM40AVE manual GM40AVE sell sheet FM1D 20 setpoint programming FM2D 50 setpoint programming Intermatic timers and manuals |
Woods Wifi 30 amp Woods 50054 WiFi contactor Auto detect voltage/ 120, 208, 240, 277 volt WiOn contactor connects to app on phone How to wire wifi Buy DEWENWILS brand wifi Wifi power switch WiOn contactor from Amazon GE z-wave contactor Resource: How to wire WiOn for 120 volt and 240 volt GE z-wave manual |
|
GE timers and manuals |
GE 15135 40 amp 120V-208V-240V-277V Dip switches to select voltage 24 hour, 15 minute intervals Buy: Tork TU timer/ same features/ same wiring GE 15135 24-hour/ 40 amp/ outdoor box at Amazon If unavailable Replace with Tork TU timer Option 1: Use Intermatic GM40 / same features and wiring Option 2: Use Open frame relay How to wire open frame relay Option 3: Use mechanical 24-hour timer Mechanical timers Manuals/ Resources: GE 15207 manual How to wire GE indoor 15207 |
GE 15136 digital 40 amp 120V-208V-240V-277V Dip switches to select voltage 7-day programmable, 9 on 9 off set points, with countdown and random options3 month power outage back-up Buy: Tork DTU 7-day programmable timer/ same features, same wiring GE 15136/ 7 day/ 7 programs /40 amp/ outdoor metal box https://amzn.to/32zjema If unavailable: Option 1: Use DTU 40 / same features and wiring Option 2: Use Open frame relay How to wire open frame relay Option 3: Use mechanical timer Mechanical timers Resources: GE 15132 manual How to wire GE 15136 |
|
Larger image Permanent ON-OFF override |
Tork
TU series 40 amp 120V-208V-240V-277V Automatically detects voltage 24 hour 15 minute intervals Buy: Tork TU series DPDT/ 120-277V universal timer at Amazon Tork P1104FM 240V SPDT with fireman switch at Amazon Buy Tork DTU digital timer at Amazon Manuals/ Resources: Sell Sheet TU wiring manual TU instruction manual |
Larger image Permanent ON-OFF override |
Tork
DTU
digital
40 amp 120V-208V-240V-277V Automatically detects voltage Replaces the old Intermatic GM40E 7-day programmable, 7 on 7 off set points, with random option. Power outage back-up Buy: DTU40 At Amazon Manuals/ resources DTU40 instruction manual |
Larger image Permanent ON-OFF override |
Discontinued/
Replace with Tork TU timer Woods 59402 40 amp 120V-208V-240V-277V Select voltage using jumpers 24 hour, 15 minute intervals Buy: Tork TU series GE 15135 24-hour/ 40 amp/ outdoor box Woods 59402 timer at Amazon Manuals/ resources Woods 59401 and 59402 manual Woods timers and manuals |
24 hour mechanical timers Long lasting Skip-a-day option Repairable with widely available parts Resources: Intermatic 24 hour timers Tork box timers Compare all box timers |
240
Volt and 208 volt Wire GM40 for 240Volt water heater Basic 240Volt wiring Turns OFF both hot wires going to load Resource More ways to wire for 240Volt Figure volts amps watts for water heater Wire size charts |
|||||
Toggle between water heater and car charger Larger image This can be accomplished with simple 3-way 30 amp switch: .... your 240 volt line has 2 hot wires.... take one hot wire and run it to both the charge station and the water heater ... connect the second hot wire to the common or different-colored screw on the 3 way switch. Second wire to water heater connects to one of the other screws, and second wire to charge station connects to remaining screw. Buy: Tork TU timer 30 amp 3 way switch Buy: Eaton At Amazon Pass & Seymour At Amazon Car charger straight-blade Car charger L-blade Adapter: 3 prong dryer plug to electric car Electric connectors |
|||||
|
|||||
240
volt and 208 volt GM40 controls two 4500 watt 240Volt water heaters Turns off 1 hot wire to each water heater Use 50 amp breaker and 6 gauge wire to timer. 10 gauge ire to each water heater Timer not rated for controlling two 5500 watt water heaters Resource How water heaters work How to wire water heaters Figure volts amps watts for water heater Two water heaters Wire sizes |
|||||
240
volt and 208 volt GM40 controls two 4500 watt 240Volt water heaters using dry terminals Set dip switches for 240Volt Timer can control two different voltages, and two separate circuits. Both circuits turn ON-OFF at same time. Control any voltage with dry terminals that are separate from clock terminals Two separate wires from breaker box. Turns off 1 hot wire to each water heater Use two 30 amp breakers and 10 gauge wires when wiring two 240Volt water heaters with element wattage over 3800 watts. |
|||||
240 volt and 208 volt GM40 controls two 240Volt water heaters One or other water heater is ON. Both heaters not ON at same time Use 10 gauge wire Resource Two water heaters |
|||||
Larger image |
120-208-240
volt 3-phase Example: High leg delta GM40 3-phase timer 120 or 208 or 240Volt 3-phase line and timer must have fused disconnect Resources What is high leg delta See more 3-phase What is 3-phase |
||||
Larger image |
Toggle
between 30 amp Loads Sometimes there are not enough circuit breakers for new 240 volt 3 HP irrigation motor. Use timer to toggle between 240 volt loads, and set timer to schedule irrigation pump. When pump is off, the water heater receives power. 240Volt circuit can be cut off by turning off one hot wire. Put water heater on NC normally open terminal, so water heater is ON when pump is Off. Same can be accomplished using 30 amp 3-way switch Buy: DEWENWILS brand wifi Wifi power switch Leviton 3033-2 3-way switch at Amazon Leviton 3-way 30 amp switch Pass and Seymour 30 amp 3-way switch Dishwashers at Amazon Resource How to wire 240Volt outlets Motor resources Not enough circuit breakers |
||||
Always check pump voltage and wiring diagram located on nameplate Pump operates continuously. Install another timer on L2 Hot line to turn pump ON-OFF |
240
volt or 208 volt
2-speed pump Low speed is connected to NC terminal, and then pump operates continuously in low speed until timer turns ON. When timer turns ON, High speed turns ON. Diagram applies for both 120V and 240V 2-speed pool pumps. Other timers can be used for 2-speed pool pump: Resource T106 timer T1906 timer |
||||
|
|||||
277
volt Timers with automatic voltage detection do not have dip switches, and will detect 277 volt. GM 40: Set dip switches for 277Volt. Dip switches must be set before power is applied to timer Wiring is identical to 120Volt, with Hot and Neutral. 277 volt is a derative of some commercial 3-phase 440 volt services, and does not apply to residential 120-240 volt services. Resource How to wire 3-phase timer What is 277 volt |
|||||
277
volt Wire GM40 for two 277Volt loads Both loads turn ON-OFF at same time Do not exceed timer 40 amp rating Volts x Amps = Watts. Each electrical device has rating plate Resource Wire and breaker size charts |
|||||
Larger image |
277
volt 3-phase Wire GM40 controls 3-phase Use 277V Or 480V contactor Fused fused safety switch, or disconnect, is required on 3-phase line and timer in typical installation. Resource How to wire 3-phase timer See more 3-phase How to wire fused safety switch |
||||
120
volt Wire GM 40 for 120Volt water heater Set dip switches for 120Volt. Dip switches must be set before power is applied to timer |
|||||
120
volt 2 loads Both loads turn ON-OFF at same time Do not exceed timer 40 amp rating Volts x Amps = Watts. Each electrical device has rating plate |
|||||
Larger image |
120
volt 3-phase
Use GM40 to control 3-phase circuit Most buildings with 3-phase also have 120Volt outlets. Use 120volt to power timer. Wire timer as shown in illustration directly above. Timer opens-closes circuit to 3-pole contactor with 120Volt coil. Resource See more 3-phase |
||||
GM 40 timer is NOT rated
for DC voltage, but can switch 24 DC volt line Wire GM40 timer to control DC motor: Use same diagram to control any single-phase voltage. Buy: Omron-DC-Power-Relay Resource: DC relays Do not mix different gauge wires under same screws. Smaller wire comes loose, causing sparking and high heat and fire. Do not mix solid wire and stranded wire under same screw. |
|||||
Toggle between 120
volt or 240 Volt Off Peak Wire GM40 timer to toggle water heater between 120Volt and 240Volt. Wiring inside water heater is not changed Elements and thermostats will work with 120 or 240 This will not work for Whirlpool energy smart water heater, electronic water heaters, heat pumps, tankless, etc Use this technique for peak electric prices. When prices are peak, set water heater to operate at 120 volts for slower heating. Tank stays hot, but hot water does not recover quickly. Element rated for 4500 watts @ 240Volt, will consume 25% or 1125 watts @ 120Volt and heat water 1/4th as fast as 240 volt. When peak price ends, resume 240Volt operation for faster heat recovery inside tank. Resource Off-peak water heater options |
|||||
Turn
Load ON once every 10 minutes for 8 hours per day Set 120Volt cycle timer for chosen time duration. For example once per each 10 minutes. Or once each 5 seconds. The cycle timer dial rotates continually, and turns load ON-OFF for each cycle. To operate the cycle timer at different hours, install GM40 timer. GM40 timer can be installed on the Hot line before or after the cycle timer. Resource Read more CT2000 cycle timer |
|||||
Whole house surge Larger image |
Surge Resource Whole house surge protector How to wire whole house surge protector Digital timers should be protected from surge. Same with any water heater that is plugged into outlet. All new appliances and water heaters with digital controls are vulnerable to surge |
Larger image |
Control
2 water heaters using 2 EH40 timers Each water heater can have different 7-day schedule 10 gauge wire and 30 amp breaker run cooler. 30 amp circuit breaker and 10 gauge wire for water heater runs cooler with less energy loss. Breaker box lasts longer. Different wiring: For two 4500 watt water heaters, you can use one 40 amp breaker and 8 gauge wire to bring power from breaker box to the first timer. For two 5500 watt water heaters, you can use 50 amp breaker and 6 gauge wire Resource Water heater timers EH40 water heater timer Things you can do to increase amount of hot water 9 ways to save with water heater |
Buy
from my affiliate links every time/ thanks: Amazon ''As an Amazon Associate I earn from qualifying purchases'' Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |