How to wire
Intermatic T1906 T1905 T1976 T1975 20 amp timers 120 volt, 240 volt, 480 volt |
Use only 600 volt wire. Lamp cord, extension cords are not rated 600 volt. Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional. 30 amp breaker use 10 gauge / 120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker. ![]() Orange/ #10 gauge wire, with ground ... 30 amp capacity. Safe maximum: 30 x 80% = 24 amps. Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp Southwire electric tools |
Yellow
12 gauge 20 amp 120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire. ... cannot be connected to 30-40 amp breaker. 1 ![]() Yellow/ #12 gauge wire, with ground ... 20 amp capacity. Safe maximum 16 amps. Buy: 12-2 gauge/ 20 amp 12-3/ 20 amp NMB is house wiring UF is underground Rolls of stranded wire HOOK UP Wires |
White
14 gauge 15 amp 120 volt 15 amp outlet, AFCI, GFCI, timer, switch etc can be installed on 15 or 20 amp breaker. Never connect 15 gauge wire to 20-30-40 amp breaker. ![]() White/ #14 gauge wire, with ground ... 15 amp capacity. Safe maximum 12 amps. Buy: 14-2 gauge/ 15 amp 14-3/ 15 amp NMB is house wiring UF is underground |
50-60
amp breaker use 6 gauge / 240 volt 50 outlet can be installed on 50 amp breaker only ![]() Buy: 6-2 wire Southwire electric tools NMB is house wiring UF is underground |
40-50
amp breaker use 8 gauge / 240 volt 40 amp outlet can be installed on 40 or 50 amp breaker only ![]() Buy: 8-2 wire Southwire electric tools NMB is house wiring UF is underground |
![]() ![]() Copper ground wire. Every device, load, metal enclosure etc must be grounded. Ground wire must be continuous throughout installation, never switched on-off, never used as a Neutral wire. Generally ... use same size as other wire in circuit Buy: 12 gauge copper ground wire Ground wire Green ground wire Ground pigtails Ground rods/ ground clamps at Amazon |
![]() Non metallic flexible cables must carry ground wire, but do not have hazard of short circuit causing injury from shock. Armored steel cable can be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure. All conduit ...metal, plastic ... flexible and rigid ... must be attached to structure, and attached to enclosures, boxes. Movement, damage and deterioration are major cause of electrical failure. Buy: Non-metallic flexible conduit Power whip Armored cable Southwire armored cable cutter Pull boxes |
![]() Electrical tools must be insulated. Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off. Buy: Electrician tools kits KLEIN TOOLS Tools kits IRWIN tools KNIPEX Telephone cable knife Low Voltage Mounting Bracket for Telephone |
![]() 600 volt 12 ga Stranded wire ot THHN wire is good for conduit with multiple wires ... but stranded cannot be installed under screw terminals on outlets, switches, timers etc without risk ... of heat causing splayed strands ....that come loose ... and begin to arc. Connect stranded to short piece of solid copper wire, and attach solid to screw terminal. Do not solder residential or commercial wiring. Project wire, extension cords, thermostat, bell and automotive wire are not rated for residential or commercial wiring. Only wire maked 600 volt can be used for permanent household wiring. Buy: Southwire 600 volt stranded wire Rolls of stranded wire HOOK UP Wires |
![]() Protect wiring from damage Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. -Code says: Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon |
![]() ![]() Electrically insulated tools When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistance and heat on wire and creates possible weak point. Buy tools: KLEIN TOOLS Wire strippers at Amazon Electric Wire Stripping Machine Linesman pliers Utility knife at Amazon |
![]() Multimeters Voltage is tested across two separate wires. Ohms or resistance is tested across both ends of same wire. Amperage is tested along one or two points on same wire. Buy: Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line |
![]() GFCI circuit breaker A GFCI circuit breaker will protect all boxes on circuit. Circuit must be grounded. Ground wire must be continuous and connected to each piece of equipment. White wire on circuit breaker must be connected to Neutral busbar inside the breaker panel. Buy GFCI circuit breakers |
Push down![]() 1" wide Push down breaker Plug-in breaker Buy single-pole: Choose from 15 to 60 amp Eaton CL series Siemens 15-60 amp Single-pole tandem breaker Tandem breakers |
Push down![]() 2" wide Push down breaker Plug-in breakers Buy double-pole: Choose from 15 to 125 amp Choose from 15 amp to 200 amp Eaton CL series circuit breaker Siemens circuit breaker Double pole GFCI |
Wiring applies to both T1906
series timer and T1976 series timer
|
|
![]() |
Normally Open turns on with timer settings Normally Closed turns off with timer settings |
![]() Larger image |
208-240Volt/
or 480 Volt
T1906 and T1976 control 240Volt Load Same wiring applies to 208 thru 240Volt NO terminal is normally open. NO turns 'on' with timer settings. This terminal used for water heater circuit shown on left. NC terminal is normally closed. NC turns 'off' with timer settings. Use 12 gauge wire for 20 amp timer SPDT single pole, double throw. Only one Hot leg is turned off. |
![]() Larger image |
120 Volt Same wiring applies to T1905 timer and T1975 timer Only difference between these two timers is the day skipper wheel on T1975 NO terminal is normally open. NO turns 'on' with timer settings. This terminal used for water heater circuit shown on left. NC terminal is normally closed. NC turns 'off' with timer settings. Timer turns off Black hot wire, so 120V water heater has no electricity when timer is off. Wires at 120V water heater: Connect black-to-black and white-to-white wires at water heater. |
![]() |
120 Volt/
control 2 loads Same wiring applies to T1905 timer and T1975 timer Only difference between these two timers is the day skipper wheel on T1975 NO terminal is normally open. NO turns 'on' with timer settings. This terminal used for water heater circuit shown on left. NC terminal is normally closed. NC turns 'off' with timer settings. |
![]() For T1906 and T1975, White wire is Hot For T1905 and T1975, White wire is Neutral |
208-240V /
or 480V control Two
Loads T1906 and T1976 control two Loads Each Load is same voltage ranging from 208Volt to 277Volt Neither Load is turned ON at same time. Either NO Load or NC Load is active, but not both same time. Bare ground wires connect to green screw. When using White wire to carry Hot, then add black tape to tell next electrician that wire carries voltage. To control different voltages, use timer with dry terminals such as GM40. Resource: How to wire GM40 |
![]() Larger image |
208-240V/
control 2-speed pump Low speed is connected to NC terminal, and then pump operates continuously in low speed until timer turns ON. When timer turns ON, High speed turns ON. Diagram applies for both 120V and 240V 2-speed pool pumps. Always check pump voltage and wiring diagram located on nameplate Other timers can be used for 2-speed pool pump: Resource: Intermatic GM40, GE 15207 series, T106 timer, Tork DTU40 timer Pump operates continuously. Install another timer on White Hot-neutral line to turn pump ON-OFF |
![]() Larger image T1075EHD Larger image T1905HD |
T1905HD 125V heavy duty T1975EHD 480V heavy duty Wires same as shown above
Buy Timer: 1906HD heavy duty 125 volt T1975EDH heavy duty 480Volt with day skipper Resources: T1900HD series sell Sheet with wiring T1975EHD sell sheet Instruction manual Same wiring as T1905 and 1975 shown above Buy T1975EHD 480Volt heavy duty captive trippers with day skipper T1905 HD 120Volt heavy duty captive trippers with day skipper |
![]() |
Keep wires straight Use solid copper wire If wiring terminal or end of wire are covered with green, use emery board to clean terminal and sandpaper to clean wire. |
![]() |
![]() Larger image |
Both wires MUST be same
gauge Straighten each wire If wire is corroded or overheated, clean the end with sandpaper and wipe with cloth. If wire has been melted, cut back and reattach, or replace wire. Tighten screw very tight against copper wire |
![]() Use wire connector |
![]() Use push-on wire connectors |
3
wires/ or different gauge wires Join wires with wire connector or push-on connector Run jumper to screw terminal. Buy: Push on wire connectors at Amazon Red 3P connector (shown) for 10-14 gauge wire Connector assortment Resource: How to select and install wire connector |
![]() |
Fire safety/ Do not put stranded
wire under screw plate Do not install stranded wire under screw. Problem1: picture shows 2 different gauge wires under screw plate Problem2: Stranded wire will expand and contract and come loose under screw plate, even if it is the only wire under the screw plate Attach stranded wire and solid wire with wire connector, and run solid copper jumper wire to screw terminal Take photo of wires before starting. ![]() Resources: Timer caught fire Load ratings for Intermatic timers/ pdf |
|
![]() Larger image |
![]() ![]() |
10 gauge or 12 gauge? Compare your wire with short pieces of 10 and 12 gauge wire from local box store 10 gauge for 30 amp breaker. 10 gauge wire can have black-white and sometimes black-red 12 gauge for 20 amp breaker 12 gauge will have black and white wires . Resources: Match color code and amp rating for wire Basic house wiring |
![]() |
Add black tape when White wire
carries voltage (applies to 208 and 240V
circuits) With 120 and 277 Volt circuits, White wire is Neutral, and Black is Hot With 208 and 240 circuits, both wires are Hot, and both wires carry voltage Black tape on White wire identifies wire is Hot and not Neutral |
![]() Contactors/ relays |
|
|
![]() |
Buy Electronic parts Industrial supplies Tools and home improvement Home and garden Hayward pool Pentair pool Southwire electric |
![]() |
Buy
Tools DEWALT Black and Decker Stanley SKIL Makita Porter-Cable Bosch Irwin Hand tools Klein hand tools Fluke electrical testing Dremel hobby tools Campbell Hausfeld air powered Tekton automotive Powerbuilt automotive Saws and saw blades |
![]() |
Resource: Compare box timers DPDT timers Intermatic Control water heater w/ Z-wave |
![]() |
Resource: Intermatic control centers: and parts Digital control centers and parts Tork control centers and parts Subpanels All control centers and parts Enclosures |
![]() |
Resource: Programmable timers Countdown timers Off delay timers On delay timers Timer modules Din rail Twin & one-shot Woods Intermatic Tork |
![]() |
Recirculation systems |
![]() | Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |