How
to set and wire Intermatic P1353ME and PE153 Plus manuals and resources Tech support options |
Use only 600 volt wire. Lamp cord, extension cords are not rated 600 volt. Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional. 30 amp breaker use 10 gauge / 120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker. Orange/ #10 gauge wire, with ground ... 30 amp capacity. Safe maximum: 30 x 80% = 24 amps. Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp Southwire electric tools |
Yellow
12 gauge 20 amp 120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire. ... cannot be connected to 30-40 amp breaker. 1 Yellow/ #12 gauge wire, with ground ... 20 amp capacity. Safe maximum 16 amps. Buy: 12-2 gauge/ 20 amp 12-3/ 20 amp NMB is house wiring UF is underground Rolls of stranded wire HOOK UP Wires |
White
14 gauge 15 amp 120 volt 15 amp outlet, AFCI, GFCI, timer, switch etc can be installed on 15 or 20 amp breaker. Never connect 15 gauge wire to 20-30-40 amp breaker. White/ #14 gauge wire, with ground ... 15 amp capacity. Safe maximum 12 amps. Buy: 14-2 gauge/ 15 amp 14-3/ 15 amp NMB is house wiring UF is underground |
Protect wiring from damage Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. -Code says: Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon |
Electrically insulated tools When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistance and heat on wire and creates possible weak point. Buy tools: KLEIN TOOLS Wire strippers at Amazon Electric Wire Stripping Machine Linesman pliers Utility knife at Amazon |
Multimeters Voltage is tested across two separate wires. Ohms or resistance is tested across both ends of same wire. Amperage is tested along one or two points on same wire. Buy: Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line |
PE153 with metal outdoor box |
Intermatic PE153 / with P1353ME 24 hour 17 amp 3-circuit timer/ Nema 3R indoor-outdoor metal or plastic enclosure. Default voltage 120V, use voltage selector on back to change to 240V. Buy: PE153 series 3-channel timer PE153P plastic enclosure/ at Amazon P153PF plastic enclosure/ with freeze PE153F metal enclosure/ with freeze / at Amazon PE153RC metal enclosure/ with wireless z-wave/ multi-wave remote control/ at Amazon Resource: P1353 wiring diagrams P153 sell sheet with model numbers PE153 parts sheet / pdf Old models: PE153WF 100' wired remote + freeze PE153P plastic outdoor box PE153W plastic box + 100' wired remote PE153WF plastic box + freeze + 100' wired remote , PE153P, PE153PF, PE153RC |
Intermatic P1353ME digital
3-channel timer If you have a 1 speed or 2 speed pool pump ... and pool lights or a fountain pump etc .... and want automated control ... then the P1353ME timer is correct choice. Buy from my affiliate links: P1353ME Resource: P1353 manual with wiring diagrams P1353ME is a 3-circuit, 24 hour programmable timer with 3 on-off events per day, per circuit, repeated each day. The 3 circuits can control 3 separate loads (pump, lights, spa etc) ... and control each with same or different schedule .... or the P1353ME can control 2-speed pool pump and 1 other load depending on which of the 6 modes is set. Has a Countdown feature. Use 3 white buttons on face of timer to manually override programming, such as switching on the pool pump. Each of the three 17 amp relays is rated for 1 Hp pump/motor at 120V AC, or 3 Hp at 240 volt AC. Resource Motor amp chart Buy PE153 Buy: P1353ME timer replacement |
Larger image Buy: P1353 Resource: P1353ME Manual Back of P1353ME The electronics are protected by a fuse located on back of timer. Default input voltage is 120V AC. Or use jumper on back to select 240 volt AC. This is the voltage that powers the timer at terminals 1 and 2. Example wiring The 3 relays at terminals 3 thru 8 are dry; They receive no voltage when terminals 1 and 2 are connected to power. Relays can control either 120V or 240V AC. Power must be off before any wiring is done or accessories added. There are accessory connections on back of timer for firemen's switch and Intermatic 178PA28A freeze sensor. See image of installation Firemen switch turns off gas heater 15-20 minutes before pump is scheduled to turn off. Freeze sensor will turn pump ON if temperatures drop near freezing. Buy: 178PA28A Has additional connection point for remote control via the 5-channel PE650ME tansceiver (antenna) that interfaces with hand held P953 controller. |
|
Manual .pdf |
Connect 120 or 240 VAC
power to Terminals 1 and 2. Default voltage is 120V... if tou have 240 volt, the change selector located back of timer BEFORE applying voltage to Terminals 1 and 2. Different Modes let you select option based on equipment. In Mode 1, the P1353 3-channel timer can 3 loads ... and control a single-speed pump plus 2 other loads, each with different schedule. Wiring is shown below. If you have 2-speed pump, then set to Mode 2, and wire as shown on left. The timer can be programmed to schedule 2-speed operation, and can be wired for 1 additional load on terminals 7-8. This load can be a blower, or pool light or spa pump, or fountain etc, and will operate with different schedule. |
More wiring diagrams |
More wiring diagrams |
More wiring diagrams |
More wiring diagrams |
Keep wires straight Use solid copper wire If wiring terminal or end of wire are covered with green, use emery board to clean terminal and sandpaper to clean wire. |
Larger image |
Both wires MUST be same gauge Straighten each wire If wire is corroded or overheated, clean the end with sandpaper and wipe with cloth. If wire has been melted, cut back and reattach, or replace wire. Tighten screw very tight against copper wire |
|
Use wire connector |
Use push-on wire connectors |
3 wires/ or different gauge wires Join wires with wire connector or push-on connector Run jumper to screw terminal. Buy: Push on wire connectors Red 3P connector (shown) for 10-14 gauge wire Connector assortment Resource: How to select and install wire connector |
Fire safety/ Do not put stranded
wire under screw plate Do not install stranded wire under screw. Problem1: picture shows 2 different gauge wires under screw plate Problem2: Stranded wire will expand and contract and come loose under screw plate, even if it is the only wire under the screw plate Attach stranded wire and solid wire with wire connector, and run solid copper jumper wire to screw terminal Take photo of wires before starting. Resources: Timer caught fire Load ratings for Intermatic timers/ pdf |
||
Larger image |
12 Ga |
10 gauge or 12 gauge? Compare your wire with short pieces of 10 and 12 gauge wire from local box store 10 gauge for 30 amp breaker. 10 gauge wire can have black-white and sometimes black-red 12 gauge for 20 amp breaker 12 gauge will have black and white wires Buy: Southwire romex cable Resources: Match color code and amp rating for wire Basic house wiring |
Add black tape when White wire
carries voltage (applies to 208 and 240V circuits) With 120 and 277 Volt circuits, White wire is Neutral, and Black is Hot With 208 and 240 circuits, both wires are Hot, and both wires carry voltage Black tape on White wire identifies wire is Hot and not Neutral |
Wiring for discontinued PE650 tranceiver antenna |
PE650 antenna receiver with
PA118
antenna/
Discontinued PE153RC all-in-one timer, remote and receiver Discontinued Control one or two three-circuit P1353ME timers -or- one or two P4243 valve/pump actuators -or one of each P1353ME and P4243 The main function of the discontinued PE650 Panel Mounted Transceiver is to take commands from the Wireless Hand Held Transceiver (PE953) and hand them off to two mechanisms (P1353ME and/or P4243ME). Buy PE650 transceiver Resource Wiring PE650 instruction manual Sell sheet Sell sheet Parts sheet Image of wiring PE953-PE650 remote transceiver instruction manual |
Discontinued For people wanting hand-held wireless control over pool functions (and zwave devices), Intermatic makes the versatile hand held PE953 remote control that can be used to control the P1353ME timer shown above. 1) Use the water
resistant, battery-operated hand-held PE953 remote
control to override the 3-channel P1353ME timer shown above.
Use buttons 1-2-3 on remote control to override each of the 3 timer relays. What to do: Drill 1-3/8" hole on top of control panel and install the discontinued PE650 transceiver antenna. Buy Tapered drill bit Then plug one of the tranceiver connection cables into back of the P1353 timer, and this lets you use hand held PE953 to override the 3-channel timer. Read more See images The hand held PE953 will only communicate with 1 transceiver .... but the transceiver antenna has two connection cables and 4 addtional wires, so it can be connected to two devices: either two P1353ME timers shown above, two P4043ME valve actuators shown below, or one timer and one actuator. The tranceiver has 4 additional wires to connect to pool heater firemen's switch and water temperature probe. See image Buy:: P953 hand held remote control PE650 tranceiver antenna Buy valve actuator |
Discontinued control centers Buy: P1353 timer Hole saw for metal PE950 receiver and antenna P953 remote control 178PA28A air temperature sensor PA122 water probe/ temperature sensor Intermatic Digital Control Centers have various configurations for controlling pool equipment, starting with the basic 3-channel P1353 timer shown above.. .... then adding the PE950 transceiver antenna on top of control center for remote override of the P1353 timer and P4243 valve actuator ... Lagrer image Resources Remote control manual Digital control centers and manuals |
Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook 713-306-0382 US-Canada only/ English language only/ no text message |