Use only 600 volt wire. Lamp cord, extension cords are not rated 600 volt. Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional. 30 amp breaker use 10 gauge / 120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker. Orange/ #10 gauge wire, with ground ... 30 amp capacity. Safe maximum: 30 x 80% = 24 amps. Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp Southwire electric tools |
Yellow
12 gauge 20 amp 120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire. ... cannot be connected to 30-40 amp breaker. 1 Yellow/ #12 gauge wire, with ground ... 20 amp capacity. Safe maximum 16 amps. Buy: 12-2 gauge/ 20 amp 12-3/ 20 amp NMB is house wiring UF is underground Rolls of stranded wire HOOK UP Wires |
White
14 gauge 15 amp 120 volt 15 amp outlet, AFCI, GFCI, timer, switch etc can be installed on 15 or 20 amp breaker. Never connect 15 gauge wire to 20-30-40 amp breaker. White/ #14 gauge wire, with ground ... 15 amp capacity. Safe maximum 12 amps. Buy: 14-2 gauge/ 15 amp 14-3/ 15 amp NMB is house wiring UF is underground |
50-60
amp breaker use 6 gauge / 240 volt 50 outlet can be installed on 50 amp breaker only Buy: 6-2 wire Southwire electric tools NMB is house wiring UF is underground |
40-50
amp breaker use 8 gauge / 240 volt 40 amp outlet can be installed on 40 or 50 amp breaker only Buy: 8-2 wire Southwire electric tools NMB is house wiring UF is underground |
Copper ground wire. Every device, load, metal enclosure etc must be grounded. Ground wire must be continuous throughout installation, never switched on-off, never used as a Neutral wire. Generally ... use same size as other wire in circuit Buy: 12 gauge copper ground wire Ground wire Green ground wire Ground pigtails Ground rods/ ground clamps at Amazon |
Non metallic flexible cables must carry ground wire, but do not have hazard of short circuit causing injury from shock. Armored steel cable can be used as a grounded connection, and will protect wires from damage. Metal can be energized from an insulation failure. All conduit ...metal, plastic ... flexible and rigid ... must be attached to structure, and attached to enclosures, boxes. Movement, damage and deterioration are major cause of electrical failure. Buy: Non-metallic flexible conduit Power whip Armored cable Southwire armored cable cutter Pull boxes |
Electrical tools must be insulated. Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off. Buy: Electrician tools kits KLEIN TOOLS Tools kits IRWIN tools KNIPEX Telephone cable knife Low Voltage Mounting Bracket for Telephone |
600 volt 12 ga Stranded wire ot THHN wire is good for conduit with multiple wires ... but stranded cannot be installed under screw terminals on outlets, switches, timers etc without risk ... of heat causing splayed strands ....that come loose ... and begin to arc. Connect stranded to short piece of solid copper wire, and attach solid to screw terminal. Do not solder residential or commercial wiring. Project wire, extension cords, thermostat, bell and automotive wire are not rated for residential or commercial wiring. Only wire maked 600 volt can be used for permanent household wiring. Buy: Southwire 600 volt stranded wire Rolls of stranded wire HOOK UP Wires |
Protect wiring from damage Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. -Code says: Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon |
Electrically insulated tools When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistance and heat on wire and creates possible weak point. Buy tools: KLEIN TOOLS Wire strippers at Amazon Electric Wire Stripping Machine Linesman pliers Utility knife at Amazon |
Multimeters Voltage is tested across two separate wires. Ohms or resistance is tested across both ends of same wire. Amperage is tested along one or two points on same wire. Buy: Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line |
GFCI circuit breaker A GFCI circuit breaker will protect all boxes on circuit. Circuit must be grounded. Ground wire must be continuous and connected to each piece of equipment. White wire on circuit breaker must be connected to Neutral busbar inside the breaker panel. Buy GFCI circuit breakers |
Push down 1" wide Push down breaker Plug-in breaker Buy single-pole: Choose from 15 to 60 amp Eaton CL series Siemens 15-60 amp Single-pole tandem breaker Tandem breakers |
Push down 2" wide Push down breaker Plug-in breakers Buy double-pole: Choose from 15 to 125 amp Choose from 15 amp to 200 amp Eaton CL series circuit breaker Siemens circuit breaker Double pole GFCI |
T12404 control center Two timers for pool filter and clearner T10101R comes with two 120 volt T101 timers T10401 comes with two 240 volt T104 timers T10000R series/ without breaker slots/ One knockout on the right side for mounting switching device or GFCI. Two combination décor/toggle switch knockouts on the deadfront. Buy T104 replacement mechanism T104R201M replacement mechanism with fireman switch T12404R with T104201 and T104/ 208-240V with fireman switch Pentair pool Hayward pool Resources: Control centers and parts Digital control centers and parts Freeze control centers and parts |
T12404R with two T104 timers for
filter and cleaner Supply voltage is 240 volts that connects to Terminals 1 and 2 on Filter timer. Both timers have a clock motor that rotates the yellow dial once per day. The dial can have up to 12 sets of trippers for 12 ON-Off periods each day. Both clock motors are connected to terminals 1 and 2 on the Filter timer. The terminals on Cleaner timer receive no voltage unless the Filter timer is ON. This assures that pool cleaner can only run when the filter pump is ON. Filter pump must be ON so debris from the pool can be run through the sand filter. |
||
Each timer on different breaker/
2 circuit breakers Illustation shows a method for running the filter pump and cleaner on separate circuit breakers. This came from an email question from a fellow who was experiencing overload on 1 circuit breaker, and wanted to install second breaker to run the cleaner. The contactor turns ON when filter timer is ON. The contactor closes circuit so cleaner timer receives power. Whe cleaner turns ON, it is powered from the second circuit breaker. Buy: 40 amp 240Volt contactor Convert control center timers to either 120 Volt or 240 volt by changing clock motor Buy: 240 volt clock motor for T12402R 120 volt clock motor for T10101R Resources: Contactor wiring Match wire and breaker size |
||
Fireman switch is not wired with
voltage at timer Do NOT connect any voltage to wires on fireman switch. The fireman switch is connected to two wires or terminals on pool heater. The terminals at heater carry 24 volt that run to the fireman switch located on timer. As the timer dial rotates, the off tripper comes into contact with the fireman switch. This activates the switch, causing the heater to turn off approximately 20 minutes before the filter pump turns off. This prevents heater from running when the pump is off. But the heater does not require a timer with fireman switch. The heater has it's own control system and thermostat that operate completely independent of the Intermatic timer. The heater has a pressure switch that turns off automatically when water pressure in the water line drops. So when pump turns off, the water slows down, and heater turns off. In addition to the pressure switch, the heater also has high limit switch that automatically turns off heater if water inside pipe is too hot. The limit switch gives heater a back up system if the pressure switch or thermostat fail. However in some cases, you want the timer to turn off the heater before the pump turns off, so hot water is not left inside the pipe. Purpose of fireman switch is to turn off heater 15-20 minutes before the pump. That ensures maximum utilization of hot water, and ensures heater is not ON unless timer is ON. The fireman switch provides additional layer of fail safe for the heater. And then both pump and heater work together to maximum efficiency and protection. |
||
Resource: T10101R manual Match wire and breaker size |
||
|
||
Add a freeze thermostat to T12404R When temperatures drop below set point, the freeze override will send power to the Filter pump. Power is also on the cleaner timer. Buy PA102 mechanical thermostat and SPDT relay Freeze control Inline freeze switch/ 15 amp max Resources: How to wire PF1202T and PF1222TB Intermatic freeze controls and manuals Resource How to make a freeze outlet |
||
Troubleshoot
T12404R -Flip circuit breaker fully off and then back on. -Check that both clock motors are connected to terminals 1 and 2 on the Filter timer. -Observe if both clock dials are rotating 1 revolution per day. If dials are not rotating, then clock motor is bad, unit is not getting voltage, or is getting incorrect voltage. -Convert timer to either 120 Volt or 240 volt by changing clock motor Buy: 240 volt clock motor for T12402R 120 volt clock motor for T10101R -Check if each clock dial has ON and OFF trippers fastened to yellow dial. -Move both override levers to ON position. If Filter pump is OFF and Cleaner pump is OFF, then move both override levers to ON position. If Filter pump works and Cleaner pump works, then voltage is correct and wiring is correct. -If all the above steps function correctly, observe if the trippers push the override lever back and forth between ON position and OFF position. If the dial rotates tripper past the override lever, and override lever does not change position, then most likely problem is worn trippers need to be replaced. Buy: trippers 156T1978A set 2 156T1978A trippers PA115 - 25 sets -If the trippers are sliding past the override lever, and new trippers do not solve problem, then replace timer module. Buy: T101M 120 volt mechanism only T104M 240 volt mechaism - Undersized wire and breaker can cause malfunctions. - Check that motor load is working correctly. Look at rating plate on motor for voltage and amperage requirements. - Convert control center timers to either 120 Volt or 240 volt by changing clock motor Buy: 240 volt clock motor for T12402R 120 volt clock motor for T10101R -If the above steps check OK, then check terminal connections and wires. Max 2 wires under a terminals. Do not use stranded wire. Clean corroded wires with sandpaper, or use white vinegar to help dissolve build-up on terminals. Tighten screws very tight against copper wire. Use only copper wire. |
T104M201 mechanism with fireman switch Buy: T104M201 mechanism with fireman |
Larger image T104M Mechanism only Buy: T104M at Amazon |
Larger image Both wires MUST be same gauge Straighten each wire Tighten screw very tight against copper wire |
Larger image Connect stranded and solid with wire connector and run jumper to screw plate. Or add solder to stranded wire to make solid. See example image |
|
12 Ga |
10
gauge or 12 gauge? 10 gauge is larger/ for 30 amp breaker. 12 gauge is smaller/ for 20 amp breaker 10 gauge wire can have black-white or black-red 12 gauge will have black and white wires Buy short pieces 10 and 12 gauge wire at local box store Compare with your wire. Resource: Match color code and amp rating for wire |
|
Circuit
breaker resources Water heater is tripping breaker How to replace circuit breaker How to wire gfci Can AC breaker be used for DC breaker How to reset circuit breaker Not enough space for circuit breakers/ use tandem Circuit breakers How to install subpanel Why you need ground wire See inside breaker box How to wire safety switch How to wire whole house surge protector Figure volts amps and watts Figure correct wire and breaker Types of surge protection |
120 Volt Push down breaker Plug-in breakers Fit residential panels Buy single-pole: Siemens 15-60 amp Single-pole tandem breaker Resource: Replace circuit breaker Not enough space inside breaker box |
240 Volt Push down breaker Plug-in breakers Fits residential panels Buy double-pole: Siemens 15-125 amp Resource: See inside main breaker box |
Buy indoor/ outdoor subpanel: 120-240 Volt Subpanels at Amazon Use up to rated amps Resource: How to wire subpanel |
Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp NMB is house wiring UF is underground Resource: Match breaker and wire size |
Buy: 12-2 gauge/ 20 amp 12-3/ 20 amp NMB is house wiring UF is underground |
Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |