Intermatic
Defrost timers and manuals Time-Time /or/ Time-Pressure-Temperature How defrost timers work |
DTMV40/ 120V 208V 240V Time initiate/ pressure or temperature terminate Buy DTMV40 at Amazon Resources Manual More information |
DTAV40/ auto detect 120V 208V 240V Time initiate/ pressure or temperature terminate Buy DTAV40 at Amazon Resources Manual More information |
DTAV40E2/ auto detect 120V 208V 240V Time initiate/ pressure or temperature terminate Buy DTAV40E2 at Amazon Resources Manual More information |
Paragon 9145 universal defrost/ 1 NO 2 NC Time initiate/ pressure or temperature terminate Buy: 9145-00 at Amazon Resource Manual |
DTAV40E 50-60 cycle Buy DTAV40E Resources Manual More information |
DTSX also snaps into paragon enclosues Buy: True service DTSX at Amazon Resource Manual More information |
G8000 series/ 1-NO 1 NC Buy: 8045-00/ 120 volt 8045-20/ 240 volt 8145-00/ 120 volt 8145-20/ 240 volt Sell sheet with wiring More information below |
Paragon or Supco 8145-20/ 1 NO 1 NC 8045-20/ 1 NO 1 NC Time initiate/ pressure or temperature terminate Buy: Supco S8145-20 /240 volt Paragon 8145-20 / 240 volt 208-240V at Amazon Supco S8045-20/ 208-240V at Amazon 8045 series at Amazon Sell sheet with wiring |
Paragon 8141 Defrost timer Time initiate/ time terminate 2 NC 1 NO/ 3 loads/ 690 watt each Metal indoor enclosure Buy: Supco S8141-20/ 208-240V at Amazon Paragon 8141-00/ 120 volt At amazon 8141 series at Amazon Sell sheet |
Larger image Nema 1 metal indoor box Buy metal or plastic enclosures |
G8000
series/ Easy
3 step set/ Nema 1
Indoor metal box Matches model for model popular Paragon 8045-8145 defrost series Buy: 8045-00/ 120 volt 1-NO 1 NC terminals/ time initiate-time termination 8045-20/ 240 volt 1-NO 1 NC terminals/ time initiate-time termination 8145-00/ 120 volt 1-NO 1 NC terminals/ time initiate-pressure/temperature/time terminate 8145-20/ 240 volt 1-NO 1 NC terminals/ time initiate-pressure/temperature/time terminate Supco defrost timer at Amazon G8000 series Resources/ Manual Sell sheet Sell sheet Sell sheet with model numbers and wiring Instruction manual G8000 wiring terminals: terminal #4 NC/ terminal #3 NO |
Larger image Dip switches for voltage |
Intermatic
DTMV40 defrost timer/ Dip switch 120-208-240VAC / Nema 3R
plastic outdoor box 40 amp 120V 1HP 240V 2HP/ Up to 8 gauge wire Time initiated- temperature-pressure terminated DTQMV 40 has 7-day back-up battery 15 minute segment intervals 1-24 timing actions per day 15 to 180 minute defrost duration Indicator lights show defrost or refrigeration Buy: DTMV40 defrost timer at Amazon DTMV40 defrost timer at Amazon Grasslin DTMV at Amazon DTMV40 timer wiring Resources/ Manuals DTMV40 Instruction manual DTMV40 instruction manual 2 Defrost timer sell sheet New sell sheet How to wire DTMV40 as on-off timer See Paragon defrost timers with explanation of defrost cycle |
Larger image Dip switches for voltage |
DTMV40
M/ mechanism only/ dip switch voltage
selection (not same as DTAV40M shown below) Time initiated, temperature, pressure or time-terminated DTQMV with 7-day battery back up Buy: DTMV40-M at Amazon True Mfg 831994 at Amazon 831994 at Amazon DTQMMV40 with back-up battery at Amazon Bracket mounted DTMV40 at Amazon DTMV40-B mechanism with bracket at Amazon DT-B defrost timer bracket at Amazon Buy metal or plastic enclosures Resources Sell Sheet DTMV40 Instruction manual DTMV40 instruction manual 2 |
Mechanism
w bracket DTMV40-B defrost timer bracket mount DTQMV40-B with 7-day battery Buy: DT-B defrost timer bracket at Amazon |
|
Larger image |
GE-Grasslin-True
DTSX Maybe old version DTMV40 above DTSX-IM-120 = 120 volt DTSX-IM-240 = 240 volt No dip switches Buy: DTSX-IM-240 mechanism qand indoor box 240 volt DTSX-B-220 / 831994/ mechaims only 120 volt Resources Manual Wiring for 8145 time initiate, hot gas terminate Wiring for 8045 time initiate, time terminate Intermatic enclosures |
Larger image No dip switches for voltage MODE selection switch |
DTAV40
defrost timer/ DTAV40Q w/ carryover/ auto-detect voltage 120-208-240V/
Mode selection switch/ Nema 3R plastic outdoor box Time initiated- time terminated Time initiated- temperature-pressure terminated 15 minute tripper intervals Type 3R indoor-outdoor Nema 3R enclosure, DTAV40Q 7-day battery carryover Auto-voltage for 120V or 240Volt / 50,000 operations at full load Time Initiated, Temperature or Pressure or Time terminated No dip switches for voltage 40 amp 2 HP MODE selection switch Use Mode A to replace Paragon 8145, 8045, 8041, 8141, 8245 Use Mode B to replace Paragon 8047, 8143, 8247 Buy: DTAV40 defrost timer at Amazon DTAV40 defrost timer at Amazon Buy: Quartz with carry-over: DTAV40Q quartz battery carry-over defrost timer at Amazon Buy: mechanism only: DTAV40M defrost timer mechanism at Amazon DT-B defrost timer bracket at Amazon Resources/ Manual DTAV40 Sell sheet with model numbers DTAV40 Sell Sheet and wiring diagrams DTAV40 Installation and instruction manual Wiring changeover for Paragon Paragon defrost timers 8145-20 8045-20 8143 8041 8141 |
DTAV40M mechanism
only (not same as DTMV40-M shown above) Buy: DTAV40M defrost timer mechanism at Amazon DT-B defrost timer bracket at Amazon Buy metal or plastic enclosures Resources DTAV40 Sell sheet with model numbers DTAV40 Sell Sheet and wiring diagrams DTAV40 Installation and instruction manual |
|
DTMV40-B
defrost timer bracket mount DTQMV40-B with 7-day battery Buy: DT-B defrost timer bracket at Amazon |
|
Larger image |
DTAV40IM/ same as
above except metal indoor box instead of plastic indoor-outdoor box Time initiated- time terminated Time initiated- temperature-pressure terminated with remote switch Type 1 Metal indoor enclosure/ not raintight Buy: DTAV40IM at Amazon Intermatic DTAV40IM sellers at Amazon Resources DTAV40 Sell sheet with model numbers DTAV40 Sell Sheet and wiring diagrams DTAV40 Installation and instruction manual |
Larger image MODE selection switch |
DTAV40E2
defrost
timer/ 7-day or 24-hour programmable/ battery
back-up/ auto-detect voltage 120-208-240V/ Mode selection
switch to match competive models Time initiated- time terminated Time initiated- temperature-pressure terminated Type 3R indoor-outdoor Nema 3R Auto detect voltage 40 amp. 8 gauge wire 50-60 Hz MODE selection switch For example use Mode A to replace Paragon 8145, 8045, 8041, 8141, 8245, Precision 6045, 6041, 6145, 6141 Use Mode B to replace Paragon 8047, 8143, 8247 Buy: DTVAE2 at Amazon Intermatic DTAV40E2 sellers at Amazon Resources DTAV40E2 sell sheet/ pdf How to program 7-day DTAV40E2 timer module/ pdf Basic DTAV40 manual with wiring diagrams and competitive replacement chart/ pdf |
Larger image |
DTAV40E
defrost timer Time initiated- time terminated Time initiated- temperature-pressure terminated with remote switch Type 3R indoor-outdoor Nema 3R Auto detect voltage 120-240 20 ON-OFF setting per 7-day or 24-hour 40 amp. 8 gauge wire 50-60 Hz Buy DTAV40E Resources How to program 7-day timer module/ pdf Basic DTAV40 manual with wiring diagrams and competitive replacement chart/ pdf |
Contactors/ relays |
|
|
Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |