Intermatic freeze controls/ and partsSearch Search using google with ads |
Buy Pentair pool Hayward pool Southwire Resources How to wire 2-speed pool pump |
PF1112T Larger image |
PF1112T/
freeze control / plus one
T104M 240Volt mechanism/ 3 Hp/ 40 amp timer Knock outs for GFCI outlet/ or switches Buy control center: PF1112T panel/ no breaker slots, 1 timer at Amazon Resources Sell sheet with dimensions/ pdf Sell sheet with models Parts sheet /pdf PF1112 manual Wiring illustration for PF1112T freeze control and T104 timer Buy parts Freeze replacement PF1102M 240Volt freeze replacement with relay Add fireman switch to timer Trippers156T1948A set (dial hold up to 12 on and 12 off trippers) Replace clock motor: WG1573 208-277V Buy T104M clock mechanism Buy T104M201 clock mechanism with fireman switch |
Large image of wiring |
How
to wire freeze thermostat PF1112T wiring How to wire PF1112T |
PF1202T Larger image |
PF1202T/
freeze control / plus two
T104M 240Volt mechanism/ 3 Hp/ 2-40 amp timers Knock outs for GFCI outlet/ or switches Buy control center: PF1202 freeze control panel / no breaker slots/ plus 2 timers At Amazon Resources Sell sheet with dimensions/ pdf Sell sheet with models Parts sheet /pdf Parts sheet 2 PF1202 manual PF1202T manual Intermatic pool parts catalog/ pdf |
PF122TB1 Larger image Pa102 |
PF1222TB1
freeze
control / plus two
T104M 240Volt mechanism / Fireman's switch or heater protection on one timer/ plus 4 breaker slots 100 amp/ 2-40 amp timers Two 240 Volt timers/ one timer has heater turn-off or fireman switch to turn off pool heater 20 minutes before pump turns off Control pool cleaner and pool pump/ wiring options ensure that pool cleaner will not turn on unless pool pump operating Freeze control automatically turns ON pool pump when air temperature drops below set point Knock out for GFCI outlet/ or switches Buy control center: PF1222TB1 panel with 4 breaker slots, 2 timers Buy parts PA102 thermostat and relay Freeze thermostat replacement Freeze control relay 143T135 Add fireman switch Trippers156T1948A set (dial hold up to 12 on and 12 off trippers) Replace clock motor: WG1573 208-277V Buy T104M clock mechanism Buy T104M201 clock mechanism with fireman switch Resources Sell sheet with dimensions/ pdf Sell sheet with models Parts sheet /pdf Parts sheet 2 PF1202 manual PF1202T manual Intermatic pool parts catalog/ pdf |
How to wire freeze thermostat PF1202T wiring PF1222TB wiring How to wire PF1202T and PF1222TB Your incoming 240 volt connects to terminals 1 and 3 on FILTER timer.... Clock motors for both timers MUST connect to live 240 volt. This means clock motor on CLEANER timer must connect to terminals 1 and 3 on FILTER timer, or to a team block where 240 volt arrives inside the control center. This wiring ensures that both clock motors are running at all times, and both yellow dials are rotating once per day. On a control center WITHOUT freeze override, terminals 1 and 3 on CLEANER timer connect to terminals 2 and 4 on FILTER timer .... this means CLEANER timer is only ON when FILTER timer is ON... On a control center WITH freeze override, terminals 1 and 3 on CLEANER timer connect to the freeze control as illustrated, and then connected to terminals 2 and 4 on FILTER timer .... this means CLEANER timer is only ON when FILTER timer is ON, same as control center without freeze. The freeze override will send power to the Cleaner timer when temperatures drop below thermostat set point |
Look for clock number Consumes 3 watts power |
Clock motor can
be replaced Star screws 3 watt consumption = 26,280 watts per year = 26.28 Kwh per year @ .12 = $3.15 operating cost 60 Hz for US market/ 60 Hz for Europe Asia Resource: How to replace Intermatic clock motor Adapt any timer above to different voltages: Applies to T104, T174, WH40, pool timers etc WG1573 for 60 Hz 208-277V WG1573 208-240Volt WG1570 for 60 Hz 120V WG1570 120Volt WG1576 for 60 Hz 480V WG1576 480Volt CW190-10 for 24 volt 60 Hz 24V at Intermatic America use 60 Hz power. Rest of world uses 50 Hz. 50 and 60 hertz devices are not compatible. Buy 50 HZ for europe etc WG1571 motor for 50 Hz 120Volt at Intermatic WG1574 motor for 50Hz 208-277V |
PE25300F
digital control panel with freeze control All digital panels with P1353 timer module can be connected to 178PA28A freeze sensor, and water temperature sensor etc Buy: PE25300 with P1353ME timer 178PA28A air thermostat for digital controls For digital control center Go to: Resource Digital control panels and manuals and parts and z-wave |
1" wide push
down
breakers Connect wire to breaker. Tighten screw very tight against solid copper wire Hook end of breaker on rail Push breaker down onto busbar Buy: Siemens circuit breakers Breaker bases: 124TP2608A 4 breaker spaces 124T2530A 8 breaker spaces Resource: How to wire Intermatic control center breaker busbar |
|
Install
wiring devices inside the enclosure First remove rectangular knock-out(s) in dead front. Remove front panel Remove hex head screws from enclosure and install 21T156A stand-offs in place of screws. 6-32 Attach deco-style wiring device to standoffs. Replace front panel Buy: 21T156A stand-offs pack 4 each / 21T166A stand-off 3" long / pack 2/ Resource: How to wire control center GFCI |
|
Install
GFCI on side of control panel Neutral is required for GFCI outlet or GFCI combo device Buy: Intermatic WP1100C weatherproof cover Weatherproof receptacle covers Resource: How to wire control center GFCI |
|
Larger image |
Control
panel must be bonded/ refer to local code Bonded means steel panel enclosure must be directly connected to local ground rod Buy: Ground rod and clamps Bonding lugs |
Stand alone freeze controls and
parts
|
|
SPST Mechanical thermostat
turns on before air temperature reaches freezing. Works with 12-24-120-240 Volt 15 amp max Buy 178T24 Thermostat 178T24 Resources: 178T24 wiring How to wire Resource How to make a freeze outlet |
This
part consists of a freeze thermostat and a relay You can make this DIY using Omron relay and a button thermostat... Buy replacement freeze control part For PF1202T and PF1222TB PA102 mechanical thermostat and SPDT relay Buy DIY Substitute Omron 120 volt coil/ contacts rated 12 amp @120 volt load Omron 240 volt coil/ with test button/ contacts rated 25 amp @ 240 volt load Omron relays Buy: Button type Freeze thermostat Resource: How to wire How to wire DIY |
240V Larger image |
|
|||
120V Larger image |
|
Buy 2T2502GA Nema 3R Outside: 9-3/8x 5-1/2 x 3-3/4 Plastic outdoor beige Buy: 2T2502GA beige |
2T2500GA Nema 3R Outside: 9-3/8x 5-1/2 x 3-3/4 Plastic outdoor gray Buy: 2T2500GA grey Square D |
||||||
Intermatic relay for freeze controls | |||||||
Timer with freeze control/ and parts | |||||||
240V
Larger image |
|
||||||
120V Larger image |
|
||||||
|
|||||||
Larger image |
PB300
series 8 on-off programs per day 24 hour and 7-day models Replace CR2032 battery located on back of timer Buy: 120Volt 24 hour 240Volt 24 hour 240Volt 24-hour 120Volt 7-day 240Volt 7-day CR2032 battery Resources: Manual and wiring PB300 Timer modules |
||||||
Replacement modules |
|
||||||
Trippers Buy P1000 series Buy 156PB10398A 156EB1945 |
|||||||
Relays
that fit inside
Intermatic freeze controls Buy: 1435T136 relay with 120 Volt AC coil 143T135 relay with 240 Volt AC coil Buy equal Substitute Omron 120 volt coil/ contacts rated 25 amp @ 220 volt load Omron 240 volt coil/ with test button/ contacts rated 25 amp @ 220 volt load Omron relays Resource: How to wire for Intermatic control center How to wire DIY |
|||||||
Used with digital control
centers Digital control centers and manuals Buy: DC 24V DC coil 143T145A with 24Vdc coil AC 24V AC coil PA120 relay 24Vac coil Resources: Sell sheet How to test if relay is working |
|||||||
Use protective shield to cover wire connections inside box. | |||||||
2T2502GA
Outdoor plastic box (Enclosure) More Intermatic / Grasslin enclosures Keep box closed to prevent fire. Buy |
|||||||
Freeze cube / Thermo cube Turns power ON when temperature below 45F Buy Freeze cube Heat tapes |
Freeze outlet Fig-1 shows bi-metal freeze thermostat connected to 120 volt outlet This bi-metal thermostat switch turns ON when temperature drops below 35°F and automatically resets to OFF when temperature rises above 45°F. To wire outlet so that one outlet is controlled by freeze thermostat, and other outlet has power at all times, then connect freeze thermostat as shown in Fig-1, and be sure to remove break-away fin (Fig-2) located between both brass (or black) screws. Buy: Freeze thermostat Resource: How to wire freeze outlet to GFCI How to wire DIY for Intermatic control center |
PF1102 parts are replaceable
Often, people forget the durability of Intermatic timers and parts Most other companies do NOT offer the same quality, nor repair parts as Intermatic. Remove mechanism from enclosure If timer is digital, then replace CR2032 battery located on back of timer Each part is replaceable Parts ARE SHOWN ABOVE AND INCLUDE TIMER, TRIPPERS, RELAY AND FREEZE DIAL. |
Larger image |
PF1100 series: T-104
timer 240Volts with Freeze thermostat Prevent pool pump and pipes from freezing Also use illustrations below for SPDT and SPST Buy control center: PF1112T panel/ no breaker slots, 1 timer PF1222TB1 panel with 4 breaker slots, 2 timers Resources: How to wire PF1100 series timers Intermatic freeze controls PF1112T manual PF1202T manual PF1102M freeze control pdf More control centers and wiring Parts manual |
Override
switch with 178T24 freeze control Up to 15 amp Freeze control override switch Buy: 40 amp switch with 32 amp safe max Motor switch MS302 30 amp 2-pole switch Buy: Leviton 3032 30 amp switch Leviton 30 amp switch 30 amp switches |
Sticks out 1" from wall Rough-in opening 8" x 10-1/4" Overall size 9" x 12" |
Wall
heater/ 120-240 Volt Hardwired 240 Volt unit / complete kit with thermostat and wall can 120 Volt unit / complete kit with thermostat and wall can 3 feet clearance in front/ 12" clearance top & bottom, and 6" each side Heaters are rated 2000 watts to 2500 watts 20 amp breaker with 12 gauge wire/ 80% safe maximum is 16 amp 16 amp x 120 volt = maximum 1920 watts 30 amp breaker with 10 gauge wire/ safe max 24 amps x 120 volt = 2880 watts Buy: 2000 watt / 208-240 volt/ 8.3 amp / electric heater 1000 watt / 120 volt/ 8.3 amp / electric heater 30 amp single-pole GFCI circuit breaker GFCI breakers Resource Cadet wall heater specification sheet Cadet wall heater installation Cadet wall heater safety tips/ pdf side Color code for wire/ match breaker and wire size How to wire GFCI single-pole breaker How to install subpanel |
Buy
from my affiliate links every time/ thanks: Amazon ''As an Amazon Associate I earn from qualifying purchases'' Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |