3 phase electricity
See inside main breaker box/ Single phase
What is 3-phase electric
Surge protection terminology
Home
Search all results
Search using Find button  
 Tweet button  
''Guidelines to consider when choosing a Surge Protection Device
1. Geographic location
a. Exposure to utility grid switching
b. Locations susceptible to brownouts or frequent utility power switching
2. Point of installation (also see types of SPD within definitions)
a. Protect equipment which is located near switching motors or transformers
b. Sensitive equipment: Computers, home theater systems, appliances which have sensitive electronics should be protected
System Voltage
The wiring diagrams characterize common voltage configurations available for the products. Refer to individual product pages for
models available in below configurations. Match the voltage configuration below with your voltage configuration at your service
entrance, distribution panel or panelboard location where you want protection.''
''Surge: A sudden and sharp increase of current or voltage within electric circuits.

SURGE PROTECTIVE DEVICE (SPD): A device used to limit a surge on equipment by diverting or limiting it. SPDs were previously
known as Transient Voltage Surge Suppressors or secondary surge arresters.

SHORT CIRCUIT CURRENT RATING (SCCR): The measurement of how much current the electrical system can supply during a fault
condition. This value determines where an SPD may be installed. (Listed on the product)

NOMINAL DISCHARGE CURRENT (In): Peak value of the current through the SPD having a current wave shape of 8/20 where the
SPD remains functional after 15 surges. (Listed on the product)

NOMINAL SYSTEM VOLTAGE: The voltage level at which a system normally operates.
Nominal system voltages include, but are not limited to, 120, 208, 240, 277, 347, 480, 600 VAC. (Listed on the product)

MODES OF PROTECTION: Electrical paths within a system which an SPD offers defense against surge events.
Examples of protection include, Line to Neutral (L-N), Line to Ground (L-G), Line to Line (L-L) and Neutral to Ground (N-G). (Listed
on the product)

VOLTAGE PROTECTION RATING (VPR): The value assigned by UL which specifies the measured limited voltage value of the SPD.
VPR rating is formally known as the “suppressed voltage rating”. (Listed on the product)

MAXIMUM CONTINUOUS OPERATING VOLTAGE: The maximum RMS voltage that may be applied to each mode of a surge
protection device. (Listed on the product)''

''Clamping Voltage (Also known as Let-Through Voltage)

The voltage at which a surge suppressor performs its suppression tasks such as diverting (shunt) the surge from line to ground or absorbing the excessive energy.

Common Mode

When relating to SPDs, common mode refers to surge protection components provided between L-G and N-G modes.

Maximum Continuous Operating Voltage (MCOV)

The maximum voltage that can be continuously applied to each mode of the SPD without degradation.

Maximum Surge Current Rating
The maximum 8x20us Surge Current Amps an SPD can withstand 1 time without performance degradation of more than 10%.

Nominal Discharge Current (IN)
The peak value of an 8/20 μs current waveform, selected by the manufacturer, for which an SPD (Type 1 or Type 2 only) remains functional after 15 surges - Type 1 devices require testing at 10 or 20 kA and Type 2 devices can be tested using a 3, 5, 10 or 20 kA.

Normal Mode
When relating to SPDs, normal mode refers to surge protection components provided between L-L and L-N modes.

Per Mode
A “mode” is a potential path for a surge to be diverted to (such as L-N, L-G, N-G).

Per Phase
The maximum amount of surge current a SPD can shunt to ground during a surge event on one phase.

Short Circuit Current Rating (SCCR)
The suitability of an SPD for use on an AC power circuit that is capable of delivering not more than a declared current at a declared voltage during a short circuit condition.

Surge
A short-duration overvoltage spike or disturbance on the ac power line, having duration of a few milliseconds or less.

Suppression Voltage Rating (SVR)
Term used to define the clamping voltage when subjected to the UL 1449 2nd Edition Measured Limited Voltage Test - this test has proven insufficient to adequately evaluate SPD performance, and has been replaced by the Voltage Protection Rating (VPR).

Temporary Overvoltage (TOV)
An overvoltage on the AC power line that is at a given location of relatively long duration (seconds, even minutes).

Type 1 Surge Protection Device
Permanently connected SPDs intended for installation between the secondary of the service transformer and the line side of the service equipment overcurrent device, as well as the load side, including watt-hour meter socket enclosures and intended to be installed without an external overcurrent protective device.

Type 2 Surge Protection Device
Permanently connected SPDs intended for installation on the load side of the service equipment over current device; including SPDs located at the branch panel.

Type 3 Surge Protection Device
Point of utilization SPDs, installed at a minimum conductor length of 10 meters (30 feet) from the electrical service panel to the point of utilization, for example cord connected, direct plug-in, receptacle type and SPDs installed at the utilization equipment being protected.

Type 4 Surge Protection Device
Component assembly consisting of one or more Type 5 components together with a disconnect (integral or external) or a means of complying with the limited current tests.

Type 5 Surge Protection Device
Discrete component surge suppressors, such as MOVs that may be mounted on a PWB, connected by its leads or provided within an enclosure with mounting means and wiring terminations.

Voltage Protection Rating (VPR)
The new terminology for what was previously known as clamping voltage, suppression voltage rating (SVR), or let-through voltage. It represents the clamping voltage when subjected to the UL 1449 3rd Edition Measured Limited Voltage Test. This newly modified test is performed at significantly higher currents (6kV @ 3000A vs 6kV 500A) to more accurately reflect real world performance.

Note: As with all SPDs, this standard only protects against surges that travel along the electrical pathway and does not protect against
direct lightning strikes traveling down non-electrical paths. For Type 2 SPDs, your SPD is only as useful as your weakest breaker. Make
sure sizing of breakers within the electrical panel are at least a 20 amp dual pole breakers to aid in preventing short circuits before the
SPD becomes functional. Type 1 SPDs are normally mounted before the panels which would not include a breaker.''
Surge protection devices
Intermatic IG1240RC3
Whole house surge
120-240V
Install at service panel or branch panel
Type 2 surge suppressor
Whole house surge will protect all 120Volt and 240Volt microwave, dishwasher, water heater, dryer, washing machine, water heater, timer,  breaker, wire etc.
Buy:
Whole house surge protectors
Intermatic Type 2 residential breaker box
Intermatic lower cost residential

Resource:
Intermatic IG1240RC3 .pdf
Intermatic IG1240RC3
Whole house surge
120-240V
Install at service panel or branch panel
Type 2 surge suppressor

Applies to all surge: Install as close to breaker as possible, Keep wires straight, no sharp angles, use sweeping bends, do not wrap extra wire, cut to length
Buy:
Leviton residential surge protector

Resources:
Leviton 5120-1 whole house surge protector/ pdf
surge protector
Best seller
Residential whole house. Type 2
Install at service panel or branch panel
Connect to breaker
12 gauge wire
120-240Vac
Nema 4X indoor-outdoor harsh environment.
Buy
Square D / HEPD80 at Amazon

Resource:
HEPD surge protection .pdf
Dimensions, mounting, wiring/ pdf
Intermatic AG3000
With 3 year $7500 warranty
Larger image
120-240 Vac with brown-out protection.
Home or commercial $7500 connected warranty/ includes electronic components.
Type 1-2 with 36" long, 10 gauge wire
Requires Neutral wire
Nema 3 indoor-outdoor
Buy:
AG3000 universal surge protection
PS3000 surge protector
Pool and spa surge protection
Resources:
AG3000 Surge protection manual
PS3000 surge protection manual
$7500 warranty/ pdf
Read about compressor defender
secondary surge arrestor
Secondary surge arrestor. Type 1
120-240V 150 VAC
Indoor/ outdoor can be located anywhere on electrical system
Type 1 surge arrestor 25,000 amp
Use for pumps, motors, service entrance
Locations more than 90' from service
Nema 4X harsh environment

Arrestor: when energy is large enough, it jumps the gap to ground or earth
Buy:
Square D secondary SDSA1175 3-wire

Resource:
SDSA1175 .pdf
Dimensions, mounting, wiring/ pdf
Homeline surge protector
120-240V
Type 2
500V clamping/ 27,000 amps
Install in breaker box, directly on busbar in place of a circuit breaker
Connect white wire to neutral busbar
Buy:
Square D push-on type residential surge protector at Amazon

Resource:
Plug on surge protection .pdf
Dimensions, mounting, wiring/ pdf

120-240V
Type 2
Install in breaker box, directly on busbar in place of a circuit breaker
Connect white wire to neutral busbar.
Buy:
HOM2175SB at Amazon
Whole house surge protectors
Siemens secondary surge protector and circuit breaker
QO type surge at Amazon

Snap-on breaker use Homeline QO2175SB for square D QO-type panels
Resource:
Plug on surge protection .pdf
Dimensions, mounting, wiring/ pdf
Intermatic surge protection
 Type 1 or Type 2, Nema4X rainproof.
Simple install vertical or horizontal etc
36" leads/ 12 gauge wire/ Cut to correct length, do not coil or wrap extra wire, avoid 90 degree bends, min 4" radius on bends, keep wires straight
Do not wrap extra wire. Cut to size.
Buy:
AG24013 Type 1 Type 2

Resource
AG series sell sheet/ pdf

phase monitor
Phase monitor or Voltage monitor
Is not surge protection.
Protects inductive loads (motors, pumps) from low voltage, or voltage differences between wires.

Buy:
Single phase 95-270 volt range
3-phase 80-300 volt range
ICM phase monitor<
Siemens monitoring relay

Resource:
How to wire phase monitor
co-ax surge protector
Co-ax surge
Type 3 surge protection
Connect to ground surge protectors
Redirects surge to ground rod
Arrestor: when energy is large enough, it jumps the gap to ground or earth.

Buy:    
Ethernet surge protector
Broadband cable lightning surge
Co-ax surge protector
Type 3 surge protection
Coax surge
Combine 4 telephone, 2 coax surge

Resources:
IG1300-surge /pdf

Buy:
24 Volt DC surge protector
Wall outlet surge protector   Outlet polarity
Image of back
Wall outlet surge suppression/ Type 3, redirects surge to ground wire. 120 volt point-of-use for electronics, gas water heaters/ tankless, microwave, machine tool, copier, cell phone charger etc. Indoor application. Meets standard for damper-type water heaters that plug into outlet.
Type 3/ Two surge-suppression outlets protects against voltage surge/
Single-event protection requires replacement.
Hot, neutral and ground wire needed/ can replace any ordinary outlet.
Buy:
15 amp surge suppressor receptacle
Leviton J-box surge protection kit
15 amp duplex surge protector
20 amp commercial surge protector
Resources
Surge protection sell sheet
Outlet surge suppression manual
Surge protection outlet manual
Guaranteed protection  ... backed by money from Intermatic
Intermatic compressor defender
$25,000 warranty/ 10 year
Intermatic compressor defender protects brown-out and surge.
Type 1 Type 2 single phase / / Nema 4X harsh environment
Surge protection PLUS brownout protection . In event of low voltage, the defender protects machinery and HVAC motors that can overheat when voltage is reduced by brownout.
Residential + light commercial
Buy:
Compressor defender at Amazon
Resources:
Read about compressor defender
Install video
Intermatic surge protection module
$25,000 warranty/ 10 year
Larger image    Another image
Intermatic modular surge protection/ replace module instead of hardwiring another device after surge event. Modules snap into place.
Type 1 Type 2 single phase / / Nema 4X harsh environment

No need for rewiring when surge is replaced > turn off circuit breaker > insert new module > turn on circuit breaker > job is done, and protection is guaranteed.
Buy
Whole house type 1 2 surge protection with 10 year warranty
Replacement module for type 1 and 2 with 1 year warranty

Resources:
Installation video
Sell sheet
Manual with wiring/ 10 gauge wire

Buy from my affiliate links every time/ thanks:
Amazon
As an Amazon Associate I earn from qualifying purchases
Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission

E-mail: geno03245w@gmail.com
My response might end up in spam folder, check email folders
Waterheatertimer on Twitter
Message thru facebook