How
to wire Intermatic sprinkler and irrigation timers and manuals How to Set & Troubleshoot Intermatic sprinkler timer.pdf Sell sheet with model numbers/ pdf E-mail: geno03245w@gmail.com |
Use only 600 volt wire. Lamp cord, extension cords are not rated 600 volt. Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional. 30 amp breaker use 10 gauge / 120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker. Orange/ #10 gauge wire, with ground ... 30 amp capacity. Safe maximum: 30 x 80% = 24 amps. Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp Southwire electric tools |
Yellow
12 gauge 20 amp 120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire. ... cannot be connected to 30-40 amp breaker. Yellow/ #12 gauge wire, with ground ... 20 amp capacity. Safe maximum 16 amps. Buy: 12-2 gauge/ 20 amp 12-3/ 20 amp NMB is house wiring UF is underground Rolls of stranded wire |
White
14 gauge 15 amp 120 volt 15 amp outlet, AFCI, GFCI, timer, switch etc can be installed on 15 or 20 amp breaker. Never connect 15 gauge wire to 20-30-40 amp breaker. White/ #14 gauge wire, with ground ... 15 amp capacity. Safe maximum 12 amps. Buy: 14-2 gauge/ 15 amp 14-3/ 15 amp NMB is house wiring UF is underground |
Sprinkler timer Parts | |
Buy extra 15 minute trippers: 156T1950A trippers |
Buy clock motors for sprinkler timer: 240volt WG733 motor 125Volt WG730 motor 480Volt WG736 for R8800 series |
133T700A micro switch 133T700A Micro Switch/ jpg Buy 133T700A Micro Switch |
Transformer for T8845PV 120volt input, 24 volt 20 Watt output Buy replacement transformer: 119T86A Transformer Substitute different transformer 24 volt AC 40 watt 24 volt DC 200 watt |
124T2097 insulator Buy 124T2097 Resource How to install insulator |
107T73
Day wheel pin 107T119 Silver tripper for 12 midnite 143T139A relay for R8806P101 133T1115A toggle switch Resource Parts accessories/ pdf |
Electrical ratings |
Motor
HP
amps @
120V
amps @
240V
Generally 1/6 HP 3 amp -- Bathroom fan/ some pond pumps 1/4 HP 6amp 3amp Bathroom fan/ gable end vent /some whole house fans 1/2 HP 10amp 5amp Gable end vent / some whole house fans/ some pumps 1 HP 16amp 8amp Water well pump/ Pool pump/ Heater pump/ water well pump Horsepower = 746 watts ... watts = volts x amps Start amps for motor loads are higher for brief moment, because motors and pumps are 'inductive' loads that cause surge events, different from resistive loads like incandescent light bulb or oven element that draw both volts and amps in equal proportional. The higher amp draw from motor start-up mean that switches, timers, wire size, etc must be calculated using motor charts Motor amp charts See motor amp draw chart image Wattage consumption for motors/ pdf |
120v T8845PV / no rain sensor terminals | ||
T8845PV/
120volt
input / 24volt output/ Nema 3R weather resistant indoor-outdoor plastic enclosure Larger image no rain sensor terminals Timer has day skipper/ no rain sensor/ 1 year warranty/ up to 44 on-off operations per day/ has ON-OFF-AUTO switch 120 Volt AC Input: use max 20 amp breaker with 12 gauge wire. 24 Volt AC Output via 2 yellow wires: Connect yellow wires to 24Volt sprinkler head. Sprinkler head advances to next station each time Insert 156T1950A trippers on outer edge of yellow dial. Each tripper represents 15 minutes/ Set minimum 12 minutes- max 20 hours 45 minutes Insert four consecutive trippers for 1 hour of watering time. When 1 hour is over, then timer no longer sends 24Volts to sprinkler head, and sprinkler automatically advances to next watering station. When timer dial rotates around to the next tripper, water resumes at next watering station. Silver Pointer located on timer dial is stationary. To set current time, rotate dial until current time lines up with silver pointer. 14-day skipper wheel |
||
Larger image T8845PV ...same timer as above How to connect rain sensor to sprinkler timer that does not have rain sensor terminals For Timers without Rain sensor terminals Illustration shows how to connect Rain-Click (or any brand rain sensor) to a timer that does not have rain sensor connections. Rain click is simple on-off switch Wires on rain click are rated 24 volt AC Yellow wires from timer carry 24 volt AC Relay is ON when no rain.. Relay OFF when it has rained, so pump cannot activate when timer turns on
|
||
T8845PV
...same timer as above Finished sprinkler timer with
rain sensor Larger image Here is finished project using a rain sensor to override timer. Image shows the Dayton power relay inside a square rain-proof PVC enclosure (junction box). Small relays (or power relays etc) are rated 15 amp but have working maximum of 10 amp. Note, the sprinkler timer enclosure usually does not have enough extra space to add the relay pointer. 14-day skipper wheel Buy 1EJG9 relay Hubbell bell junction boxes 2-gang junction box 1/2" Flexible conduit For safety, all boxes must have a cover. |
||
T8845PV
same timer as above:
controls 120volt
load max 20 amp Or install 20 amp line fuse between incoming Hot wire and timer, and this will allow timer to control any voltage load The contactor requires a separate enclosure Larger image |
||
T8845PV
same timer as above Larger image If the motor load is lightweight (less than 1/2 HP), then use smaller Uxcell LY2 relay. Small relays are rated 15 amp but have working maximum of 10 amp. Contactor is best for loads that exceed 15 amp Connect. The relay needs a separate enclosure.
|
120v 15A 1/2 Hp / T8805P101/ no rain sensor terminals | |||||
Larger image |
T8805P101: 120Volt input/ 120Volt
output/ 15 amp/ 1/2 HP No rain sensor terminals T8805M101C mechanism only fits into any Intermatic enclosure No rain sensor terminals 14-day skipper wheel Buy T8805P101C 120V input 120V output timer T8805M101C mechanism-only Buy replacement parts Replacement 120V WG730 clock motor 480V WG736 clock motor Replacement 156T1950A trippers Resources: T8805P101C timer manual Sell sheet with model numbers/ pdf Sell sheet with wiring |
||||
Larger image
|
Heavy-duty relay Optional box and cover for Magnecraft Recommend this relay for motors exceeding 120 volt 1 HP/ 240 volt 2 HP Magnecraft relay with NO NC terminals 120 volt coil or 24 volt coil Buy from my affiliate links 24 Volt AC coil/ 40 amp contacts 120 volt coil/ 30 Amp DPDT relay 120 volt coil/ 40 Amp DPDT relay Magnecraft box and cover Siemens power relays Schneider W199 relay NTE open frame relays Packard DPDT fan relay Tyco open frame relay Contactors/ reliable for heavy amp loads 15 amp Relays for loads up to 10 amps |
208-240-277v 25A / 3Hp / T8806P101 no rain sensor terminals | |
Larger
image R8806P101: 208-240Volt input/ 208-240Volt output/ 20 amp/ no rain sensor terminals 14-day skipper wheel Buy R8806P101C 240V timer Buy replacement parts Replacement 208-240V WG733 clock motor 480V WG736 clock motor Replacement 156T1950A trippers Resources: R8806P101C timer manual Sell sheet with model numbers and wiring/ pdf |
120v 25A 1-1/2 HP / R8815P101C/ with rain sensor terminals | |
Larger image |
R8815P101C 120Volt input/ 120V output with rain sensor terminals Rain sensor connection: Rain sensor wires connect to two terminals on timer, located on left side. Do NOT connect household voltage wires to rain sensor terminals. On the timer, there is a switch: Set selector switch to Auto for operation of Load. Wiring the timer: There are 4 terminals for wiring. Connect Black Hot wire to terminal 1 and White neutral wire to terminal 3. Hot wire to Load connects to terminal 2 and Neutral wire to Load connects to terminal 4. 14-day skipper wheel Buy R8815P101C timer Rain Bird Wired Rain Sensor Hunter wired Rain Sensor Buy replacement parts Replacement 208-240V WG733 clock motor 480V WG736 clock motor Replacement 156T1950A trippers Manual and resources R8815P101C manual Sell sheet with model numbers and wiring |
208-240-277v / 25A 3Hp / R8816P101C/ with rain sensor terminals | |
Larger image Larger image |
R8816P101C
208-240Volt input/ 208-240V output with rain sensor terminals 208-240Volt Hot wires from circuit breaker connect to terminals 1 and 3 Wires going to Load connect to terminals 2 and 4 Ground wires connect to green ground screw. WG1573 clock motor wires are factory-connected to same terminals as both Hot wires from breaker. Rain sensor wires connect to terminals on timer. Do NOT connect household voltage wires to sensor terminals. Set selector switch to Auto for operation of Load. 14-day skipper wheel Buy R8816P101C timer Rain Bird Wired Rain Sensor Hunter wired Rain Sensor Buy replacement parts Replacement 208-240V WG733 clock motor 480V WG736 clock motor Replacement 156T1950A trippers Manual and Resources R8816P101C manual Sell sheet with wiring |
Wiring Tips | |
Keep wires straight Use solid copper, 600 volt wire (voltage printed on insulation sheathing of each wire. Never use extension cord for permanent residential or commercial wiring. Avoid stranded wire. All wire expands and contracts as power is turned on-off. Heat causes stranded wire to splay apart and get loose, eventually arcing and melting the terminal. Do not use solder on electrical connections. Solder melts with heat as power is turned on-off. If wiring terminals are corroded, try using a toothbrush and vinegar. If wiring terminals are rusted, try using WD-40 and/or fingernail sanding board. If wiring terminals are burned, try using bit of sandpaper or sanding board. If wiring terminals are melted, then timer is probably bad ... it is risky to connect wire to a damaged electrical device ... Keep timer door closed to prevent fire ... the closed door starves a fire from oxygen and extinguishes flame. |
Larger image |
|
Use wire connector |
Use push-on wire connectors |
Larger image |
|
Buy: Push on wire connectors at Amazon Red 3P connector (shown) for 10-14 gauge wire Connector assortment |
Buy
from my affiliate links every time/ thanks: Amazon ''As an Amazon Associate I earn from qualifying purchases'' Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |