T185 timer is same as T101 series timerWiring begins hereHome Applies to T185, T101, T101R, T101P, T101PCD82, T171, T171R, T171CR, T101R3, T101P3, T101R201, T101P201, T101M, T171M see all models and voltages |
Large image Indoor metal box Buy: T101 series at Amazon |
Larger image Indoor metal box/ day skipper Lets you skip one or more days per week Buy: T171 at Amazon |
Larger image Mechanism only Use thumb spring located top inside timer to remove old mechanism from enclosure Buy: T101M at Amazon |
Larger image Outdoor metal box Buy: T101R at Amazon |
Larger image Outdoor metal box/ day skipper Buy: T171R at Amazon T171RCR carry-over |
Larger image Outdoor plastic box Buy: T101P at Amazon Outdoor plastic box/ see thru door Buy: T101PCD82 |
T101R3 Outdoor metal box Buy: T101R3 at Amazon |
T101R201 Outdoor metal box/ With fireman switch Buy: T101R201 at Amazon |
T101P201 Outdoor plastic box/ With fireman switch Buy: T101P201 at Amazon |
Wiring for other models Resource: T104 & T174 wiring T103 & T173 wiring T101 & T171 wiring T101B wiring T102 & T172 wiring T105 & T175 wiring T106 & T176 wiring |
Wiring
for other T100 series timers |
|||
Detail below |
T-101
timer 120Volts Resource: T101 series T171 skip-a-day series T101R201 manual T101P201 manual Sell sheet with model numbers Replacement clock motor T100 series repair parts How to operate and set T101 timer How to find Hot wire Pool timers |
|||
T-101
timer 120Volts T-101 timer for 120 Volt water heaters T-101 SPST [single-pole single-throw] Black Hot wire must connect to pole 1. Neutral must go to pole A Black to Load goes to pole 2 White to Load goes to pole A |
||||
Larger image |
T-101
timer controls 3-phase Use T101 120Volt timer to control 3 phase loads. use wiring diagram above to control 3-pole contactor, or diagrams to left and right Neutrals connect to terminal A Hot from breaker connects to terminal 1 Hot to contactor connects to terminal 2 No fuse required on incoming line. Fused disconnect required on 3-phase line and timer in most commercial applications Resource: More 3-phase timers |
|||
Larger image |
||||
|
T-101
timer 240 Volts Convert T101 into T102 timer to control 240Volt load: Replace 120volt WG1570 clock motor with WG1573 clock motor. Connect new clock to same terminals A and 1. 240V: L1 Hot from breaker connects to terminal A; L2 Hot from breaker connects to terminal 1 240Volt wires going to Load connect to terminals A and 2. T-101 changed to 240 V (207-277) Buy: WG1573 for 60 Hz 208-277V Amazon |
|||
|
||||
T101 timer is fully repairable Resource: How to take apart and repair T100 series timers |
||||
T-101 clock motor 120 V Buy: WG1570 for 60 Hz 120 volt Amazon |
||||
T-101 clock motor 120 V Buy: WG1570 for 60 Hz 120 volt Amazon |
Change
T101 timer to different voltage by changing clock motor >>>>> |
T-101 changed
to 24 volt CW190-10 for 24 volt 60 Hz 24V at Intermatic |
||
T-101 changed to 240 V (207-277) Buy: WG1573 for 60 Hz 208-277V Amazon |
T101 changed to
60Hz to 50 Hz WG1571-10D motor for 50 Hz 120Volt |
|||
T-101 changed to 480 Volts Buy: WG1576 for 60 Hz 480V at Amazon |
How to replace Intermatic clock motor | |||
Trippers Dial can have 12 sets ON-OFF trippers Buy: 156T1978 trippers Amazon |
||||
Larger image |
Insulators -Keep insulator over screw terminals to prevent accidental electrocution hazard. Insulator pushes down over two knobs located on timer mechaism below the yellow dial. Translucent 124T1948 single pole T101, T102, T105 124T1948 single pole T171, T172, T175 Buy: 124T1948 at Amazon Black rigid 124T2411A rigid Buy: At Amazon |
|||
Convert
indoor timer into outdoor timer: Buy different enclosure. Use thumb spring located top inside timer to remove mechanism from enclosure Buy: 2T2502GA beige plastic Outdoor box at Amazon Resource More enclosures |
||||
Installation tips -Secure wire or conduit to enclosure. All wires, enclosures and conduit must be secured to structure. -Always use solid copper wire under timer screw terminals ... stranded wire can come loose and cause fires. -Keep enclosure door closed to prevent possible fire hazard from spreading. -Keep insulator over screw terminals to prevent accidental electrocution hazard. -Install enclosures away from hazards such as lawn mower or machinery. -Install outdoor boxes in sheltered area if possible and 12" above anticipated snowfall. -For safety, make sure Load is grounded correctly. People often forget to securely join the ground wires inside timer because wire sometimes gets a bit short. Buy extra length of wire from box store. Load must be grounded. Why you need ground wire |
||||
Use correct wire and breaker Oversized is OK, undersized is hazard Look at label on load to determind correct size wire and breaker Watts divided by volts = amps If Load is 120 volt, and watts is 1500 = 12.5 amps. Next calculate 80% safe maximum. 20 amp breaker x .80 = 16 amps safe maximum 15 amp breaker x .80 = 12 amps safe maximum The calculation shows that 4500 watt load requires 20 amp breaker and 12 gauge wire up to 150 feet. Longer distance, use larger wire and breaker. Buy from my affiliate links: Southwire cable and tools Resource: Figure volts amps watts |
||||
T101B
Wiring begins here Applies to T101B with separate wiring terminals |
||||
|
||||
You
can accomplish same wiring using T104 timer & change clock motor You can accomplish same wiring using T103 timer |
||||
T-101B clock motor 120 V Buy: WG1570 for 60 Hz 120 volt Amazon T-101B change to 208-277 Change T101B timer into 240 Volt Buy: WG1573 for 60 Hz 208-277V T-101B change to 480 Volts Change clock motor to WG1573 Buy: WG1576 for 60 Hz 480V at Amazon |
Change clock motor
voltage >>>>> |
T-101B change to 24 Volts CW190-10 for 24 volt 60 Hz 24V at Intermatic T-101B change from 60Hz to 50 Hz WG1571 motor for 50 Hz 120Volt at Intermatic |
Wiring for other T100 series timers |
T101B Wiring: How to wire T101B timer Applies to T101B with separate wiring terminals |
T103 Wiring: How to wire T103 and T173 series timers |
T104 Wiring: How to wire T104 timer Applies to T103, T103R, T103P, T103M, T103PCD82, T173, T173R T173M see all models |
How to wire Intermatic T102: How to wire T102 and T172 series timers |
How to wire Intermatic
T105: How to wire T105 timer Nema 1 indoor enclosure/ To convert to 208-277V operation, replace WG1570 clock motor with WG1573 clock motor |
How to wire Intermatic T106
timer: How to wire T106 timer Nema 3R indoor-outdoor enclosure To convert to 120V operation, replace WG1573 clock motor with WG1570 clock motor |
How to wire Intermatic pool timer: How to wire pool timers |
Control centers: Control centers: + manuals and parts All control centers and parts |
|
Intermatic/ Grasslin enclosures Metal and plastic enclosures |
|
Intermatic sprinkler timers and wiring | How to wire Sprinkler timers + rain sensor + manuals + buying options How to connect rain sensor when timer does not have rain terminals How to Set & Troubleshoot Intermatic sprinkler timer/ pdf |
Multi-function timers and wiring 40 amp Multi function timers and manuals |
|
T1906-5 T1975-6 heavy duty timers 20 amp Multi function timers and manuals |
|
ET
series digital timers/ 20-30 amp/ 120-277 volt/ multi-channel
(same timer controls two circuits with different programming) ET series timers |
|
Timer modules/ 16 amp/ 12-240 volt Timer modules/ 16 amp/ 12 to 240 volt |
Buy
from my affiliate links every time/ thanks: Amazon As an Amazon Associate I earn from qualifying purchases Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |