to wire Intermatic T10404R How to wire Intermatic T10101R How to troubleshoot Intermatic T10404R How to troubleshoot Intermatic T10101R Tech support options |
Multimeters Voltage is tested across two separate wires. Ohms or resistance is tested across both ends of same wire. Amperage is tested along one or two points on same wire. Buy: Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line |
Electrical tools must be insulated. Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off. Buy: 1000 volt Tool kit Electrician tools kits KLEIN TOOLS Tools kits IRWIN tools KNIPEX Telephone cable knife Low Voltage Mounting Bracket for Telephone |
Protect wiring from damage Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. -Code says: Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon |
Electrically insulated tools When removing insulation from wire, do NOT score or put cuts on surface of copper wire. Doing so increases resistance and heat on wire and creates possible weak point. Buy tools: KLEIN TOOLS Wire strippers at Amazon Electric Wire Stripping Machine Linesman pliers Utility knife at Amazon |
Weatherproof
lever switch on outdoor lights Safely operate outdoor toggle switch Replaces outdoor cover Install over top of ordinary switch Works with single-pole, double-pole, 3PST, 3-way, 4-way switches etc Use weatherproof box for outdoor Can be used indoor or outdoor Buy: Cantex lever switch Leviton lever switch Outdoor lever switches at Amazon Resource Cantex-toggle-switch-covers.pdf Cantex-PVC-junction-boxes.pdf |
Weatherproof wire connectorConnector cavity is full of siliconeBuilt-in cover keeps silicone in place Protect from water, dust etc Buy from my affiliate links Weatherproof size 14 to 6 Amazon Weatherproof size 22 to 8 Amazon Resource How to select and install connectors |
Multimeter Test for breaks in wire/ Test for voltage Most appliance require 80% rated voltage to function correctly Buy Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line Resource: How to test and replace element How to test thermocouple Element tests for 120 volts How to test wire |
Safety when testing wires: Never touch wet or previously flooded appliance. Never stand on wet surface when working on electric. Never stand on bare soil, put down dry boards. Tape tester leads to wood sticks to keep hands away from power. Use non-contact voltage tester before touching wires. Never touch or lean into any made of metal. Remove metal objects from pockets. Do not use oxygen or fuel accelerants in same room as electrical repairs Resource: Basic house wiring |
Weatherproof
outlet cover Safely use extension cord with weather resistant cover Buy: Outlet covers |
Weatherproof
box For adding outdoor wiring Drill through back of indoor box, and through wall to install new outdoor outlet. Buy Hubbell Bell PVC box Hubbell Bell aluminum box |
GFCI circuit breaker A GFCI circuit breaker will protect all boxes on circuit. Circuit must be grounded. Ground wire must be continuous and connected to each piece of equipment. White wire on circuit breaker must be connected to Neutral busbar inside the breaker panel. Buy GFCI circuit breakers |
Push down 1" and 2" wide Push down breaker Plug-in breaker Buy single-pole: Choose from 15 to 60 amp Eaton CL series Siemens 15-60 amp Single-pole tandem breaker Buy double-pole: Choose from 15 to 125 amp Choose from 15 amp to 200 amp Eaton CL series circuit breaker Siemens circuit breaker Double pole GFCI |
Intermatic T10404R and T10101R
control center Two timers for pool filter and learner T10101R comes with two 120 volt T101 timers T10401 comes with two 240 volt T104 timers Max 40 amp (safe max 32 amp). Rated for up to 5 Hp. Resource: See charts for motors: amp, distance, wire size T10000R series/ without breaker slots/ One knockout on the right side for mounting switching device or GFCI. Two combination décor/toggle switch knockouts on the deadfront. Numerous wiring knockouts located on bottom of panel. This control panel has no circuit breaker spaces, but can install surface mounted circuit breaker or a din-rail mounted fuseholder. Multiple fuses and breakers on single circuit are OK. Multiple surge protectors OK on single circuit. Caution: only 1 GFCI or AFCI per circuit. Read information how to install and wire for 120 volt outlet/ switch Buy: PE10000 enclosure/ no timer/ T10101R with 2x T101 /120V T10004R with one T104 /208-240V T10404R with 2x T104 / 208-240V T10604R with T106 and T104 /208-240V for 2-speed pumps T12404R with T104201 and T104/ 208-240V with fireman switch Resources and manuals T10000R series manual and sell sheet T10404R door label T10101R manual |
Replacement timer Use thumb spring located top inside timer to remove old mechanism from enclosure Buy: T101M 120 volt mechanism only T101 series 120 volt timers T104M 240 volt mechanism T104 series 240 volt timers T104M201 mechanism with fireman switch |
Larger image |
Step 1: Wire the control panel busbar 120 volt + 208-240 volt with breakers Use 10-3 with ground Breaker base with 8 spaces Breakers fit on either side of busbar Use single breaker for 120V, double breaker for 240 volt Resource More control panel wiring |
Household NM-B Wires are color-coded so inspectors/ electricians can easily identify which wire is used during construction Damp- wet locations: For direct burial underfoot, in contact with damp soil ... or for other damp locations ... use UF-B wire ... or use plastic conduit. UF-B wire can be difficult to strip back for wiring. |
Match
wire size and breaker amp rating If your home was wired by professional electrician who pulled permits, then circuit breaker and wire size will match. If manufactured home or travel trailer has not been altered by homeowner then breaker and wire size will match. Safe maximum of amp draw on a breaker is 80% rated value of breaker. Look at label on each load (TV, refrigerator, box fan etc). Add up total watt load on circuit. Divide the watts by the voltage on line = amps. Main breaker terminals are still Hot when main breaker is turned off. Absolute electrocution danger when removing cover off main panel. More information below. Use 600 volt solid copper wire only Do not use stranded wire inside main breaker box or any permanent box. Stranded wire can be used for connectors and plugs, but comes loose under screw terminals of breaker, switch, outlet, or timer etc when heat on wire causes expansion and contraction of wire. Do not use extension cord for permanent household wiring Extension cords are used for connectors and plugs only. Read about extension cord code Buy: Southwire at Amazon Resource: How to replace circuit breaker Ampacities source for TW and UF insulated wires: NEC table 310-16 |
Larger image |
Install GFCI
circuit breaker
inside main breaker panel? Outdoor circuits are always safer with GFCI protection, and GFCI installation might be required to meet local codes. Caution, only 1 GFCI per circuit. So if your are going to install 120 volt plugs inside the panel (as shown lower on page) then these will be automatically protected by the 240 volt GFCI breaker. Illustration shows 2-pole 240Volt GFCI. The ordinary 240Volt breaker does not have white wire The GFCI 240Volt breaker has white wire that connects to neutral busbar. Buy: 240 volt GFCI breaker GFCI circuit breakers |
T10404T with two
T104 timers for filter and cleaner Supply voltage is 240 volts that connects to Terminals 1 and 2 on Filter timer. Both timers have a clock motor that rotates the yellow dial once per day. The dial can have up to 12 sets of trippers for 12 ON-Off periods each day. Both clock motors are connected to terminals 1 and 2 on the Filter timer. The terminals on Cleaner timer receive no voltage unless the Filter timer is ON. This assures that pool cleaner can only run when the filter pump is ON. Filter pump must be ON so debris from the pool can be run through the sand filter. Fig 2 is same as Fig 1 shown above. Note that both the Filter Pump and Cleaner must be same voltage, either 120V or 240V. Timer clock voltage must match the Pump and Cleaner. The clock motors can be changed to either voltage Buy: 240 volt clock motor 120 volt clock motor Both clock motors must connect to terminals 1 and 3 on Filter Pump timer. The pool cleaner never operates unless the filter pump is running. The wiring is designed for that purpose, so that the debris picked up by cleaner gets sent through the sand filter. |
Each timer on different breaker/
2 circuit breakers Illustration shows a method for running the filter pump and cleaner on separate circuit breakers. This came from an email question from a fellow who was experiencing overload on 1 circuit breaker, and wanted to install second breaker to run the cleaner. The contactor turns ON when filter timer is ON. The contactor closes circuit so cleaner timer receives power. When cleaner turns ON, it is powered from the second circuit breaker. Buy: 40 amp 240Volt contactor Convert control center timers to either 120 Volt or 240 volt by changing clock motor Buy: 240 volt clock motor for T10404R 120 volt clock motor for T10101R Resources: Contactor wiring Match wire and breaker size |
Resource: T10101R manual Match wire and breaker size |
Add a freeze thermostat to T10404R When temperatures drop below set point, the freeze override will send power to the Filter pump. Power is also on the cleaner timer. Buy PA102 mechanical thermostat and SPDT relay Freeze control Inline freeze switch/ 15 amps max Resources: How to wire PF1202T and PF1222TB Intermatic freeze controls and manuals Resource How to make a freeze outlet |
T10101R 120
volt wiring This control center has same function as T10404R except for 120 volt installations. 240 volt motors run more efficiently than 120V. Most motors can be wired for either voltage. Look at rating plate on motor to select correct control center, wire size and breaker. Buy: T10101R control center with 2x T101 /120V Convert control center timers to either 120 Volt or 240 volt by changing clock motor Buy: 240 volt clock motor for T10404R 120 volt clock motor for T10101R Resource: T10101R manual Match wire and breaker size |
Troubleshoot
T10404 and T10101R -Flip circuit breaker fully off and then back on. -Check that both clock motors are connected to terminals 1 and 2 on the Filter timer. -Observe if both clock dials are rotating 1 revolution per day. If dials are not rotating, then clock motor is bad, unit is not getting voltage, or is getting incorrect voltage. -Convert timer to either 120 Volt or 240 volt by changing clock motor Buy: 240 volt clock motor for T10404R 120 volt clock motor for T10101R -Check if each clock dial has ON and OFF trippers fastened to yellow dial. -Move both override levers to ON position. If Filter pump is OFF and Cleaner pump is OFF, then move both override levers to ON position. If Filter pump works and Cleaner pump works, then voltage is correct and wiring is correct. -If all the above steps function correctly, observe if the trippers push the override lever back and forth between ON position and OFF position. If the dial rotates tripper past the override lever, and override lever does not change position, then most likely problem is worn trippers need to be replaced. Buy: trippers 156T1978A set 2 156T1978A trippers PA115 - 25 sets< -If the trippers are sliding past the override lever, and new trippers do not solve problem, then replace timer module. Buy: T101M 120 volt mechanism only T104M 240 volt mechanism - Undersized wire and breaker can cause malfunctions. - Check that motor load is working correctly. Look at rating plate on motor for voltage and amperage requirements. - Convert control center timers to either 120 Volt or 240 volt by changing clock motor Buy: 240 volt clock motor for T10404R 120 volt clock motor for T10101R -If the above steps check OK, then check terminal connections and wires. Max 2 wires under a terminals. Do not use stranded wire. Clean corroded wires with sandpaper, or use white vinegar to help dissolve build-up on terminals. Tighten screws very tight against copper wire. Use only copper wire. |
Install
wiring devices inside
the enclosure First remove rectangular knock-out(s) in dead front. Remove front panel Remove hex head screws from enclosure and install 21T156A stand-offs in place of screws. 6-32 Attach deco-style wiring device to standoffs. Replace front panel Buy: 21T156A stand-offs pack 4 each 21T166A stand-off 3" long / pack 2 Resource: How to wire control center GFCI Must bring 3 wire cable with 2 Hots, ground, Neutral from breaker box so the 120 volt outlets have Neutral wire. If circuit breaker is 30 amp or above, then install a line fuse to match amp rating of outlets. Buy: ANL fuseholder e2 fuseholder with platinum plating ANL fuses |
Wiring Tips | |
Keep wires straight Use solid copper wire If wiring terminal or end of wire are covered with green, use emery board to clean terminal and sandpaper to clean wire. |
Larger image |
Both wires MUST be same gauge Straighten each wire If wire is corroded or overheated, clean the end with sandpaper and wipe with cloth. If wire has been melted, cut back and reattach, or replace wire. Tighten screw very tight against copper wire |
|
Use wire connector Use push-on wire connectors |
3 wires/
or different gauge wires Join wires with wire connector or push-on connector Run jumper to screw terminal. Buy: Red 3P connector (shown) for 10-14 gauge wire Lever connectors for stranded wire |
Fire safety/ Do not put stranded
wire under screw plate Do not install stranded wire under screw. Problem1: picture shows 2 different gauge wires under screw plate Problem2: Stranded wire will expand and contract and come loose under screw plate, even if it is the only wire under the screw plate Attach stranded wire and solid wire with wire connector, and run solid copper jumper wire to screw terminal Take photo of wires before starting. Resources: Timer caught fire Load ratings for Intermatic timers/ pdf |
||
Larger image |
12 Ga |
10 gauge or 12 gauge? Compare your wire with short pieces of 10 and 12 gauge wire from local box store 10 gauge for 30 amp breaker. 10 gauge wire can have black-white and sometimes black-red 12 gauge for 20 amp breaker 12 gauge will have black and white wires Buy: Southwire romex cable Resources: Match color code and amp rating for wire Basic house wiring |
Add black tape when White wire
carries voltage (applies to 208 and 240V circuits) With 120 and 277 Volt circuits, White wire is Neutral, and Black is Hot With 208 and 240 circuits, both wires are Hot, and both wires carry voltage Black tape on White wire identifies wire is Hot and not Neutral |
Safe electric
practice for boxes/ enclosures For household 120-240 volt power: -Use only approved 600 volt cables, wires, enclosures, boxes, conduit etc for household 120-240 volt. -Extension cords are not rated 600 volt, and cannot be used for permanent in-wall wiring. Resources Extension cord code -Do not use makeshift, homemade boxes that are not rated for household voltage. -Correct box must be used for application ... a light fixture or fan requires round or octagon box ... cannot use switch box, or square junction box for light fixture ... cannot use round, octagon, or square junction box for switch and outlet. -All enclosures and boxes require a cover that is made to fit box, and must sit flat and tight against box. -Missing knockout holes must be filled. -Keep enclosure door or cover in place and closed to contain spark and potential fire hazard. -Box cannot have vent holes or heat fan installed where air supply can feed a potential fire. -Never solder household wiring connections. High heat from resistance, caused when amperage gets pushed through the wire by voltage, will melt solder and cause potential hazard. -Use only approved 600 volt wire connectors. Never reuse old wire connectors. -All enclosures, wiring, conduit etc must be attached firmly to structure, and located so cannot be damaged by lawn equipment etc. and best if located away from high heat, exposure to sun. Heat will cause deterioration of electrical installations. -Enclosures require ground wire to be present and connected to all devices, equipment etc. Metal boxes and enclosures require connection to ground wire. Plastic boxes do not require grounding. Resources: Safe electric wiring/ for boxes and enclosures Color code for wire Low-voltage structural wiring (doorbell, communication, TV etc): -Never include low-voltage 'structural wiring' inside same enclosure, conduit, raceway or box as household voltage. -Low voltage structural wiring and household wiring must be electrically separated to prevent insulation failure from energizing low voltage wires, cause fire and safety hazard. -Structural wiring can be run inside walls, does not require enclosure, box conduit etc except for installation convenience, weatherproofing, reliability, organization, access to splices and connections etc. -Household 120-240 volt wiring cannot be soldered ... but low-volt structural wires can be soldered when needed. Resource: troubleshoot low voltage doorbell |
Repair Parts/ clock motors | |
Look for clock number Consumes 3 watts power |
Clock motor can
be replaced Star screws 3 watt consumption = 26,280 watts per year = 26.28 Kwh per year @ .12 = $3.15 operating cost 60 Hz for US market/ 60 Hz for Europe Asia Resource: How to replace Intermatic clock motor Adapt any timer above to different voltages: Applies to T104, T174, WH40, pool timers etc WG1573 for 60 Hz 208-277V WG1573 208-240Volt WG1570 for 60 Hz 120V WG1570 120Volt WG1576 for 60 Hz 480V WG1576 480Volt CW190-10 for 24 volt 60 Hz 24V at Intermatic America use 60 Hz power. Rest of world uses 50 Hz. 50 and 60 hertz devices are not always compatible. WG1571 motor for 50 Hz 120Volt at Intermatic WG1574 motor for 50Hz 208-277V Amazon |
Buy trippers 156T1978A set 2 156T1978A trippers PA115 - 25 sets Intermatic mail-in order form Timer dial can hold 12 sets 1 on- 1 off for each 24 hour period |
Fireman switch turns off pool heater 10 minutes before pool pump turns off. Pool heater must have fireman connection. Do not connect power wires inside timer to fireman switch... the heater connects to fireman switch Can be installed on any T100 series timer. Resources Fireman's switch pdf How to wire fireman's switch Buy: 156T4042A Fireman switch Amazon |
156T6738A insulators Add Insulator to override switch for electric safety Buy: 124T1948 single pole for T101, T102, T105 124T1952 double-pole for T103, T104, T106 |
Buy
from my affiliate links every time/ thanks: Amazon ''As an Amazon Associate I earn from qualifying purchases'' Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |