Multimeter Test for breaks in wire/ Test for voltage Most appliance require 80% rated voltage to function correctly Buy Analog multimeter Multimeters at Amazon Klein multimeter Electric testers at Amazon Clampmeter for testing amp flow on line Resource: How to test and replace element How to test thermocouple Element tests for 120 volts How to test wire |
Safety when testing wires: Never touch wet or previously flooded appliance. Never stand on wet surface when working on electric. Never stand on bare soil, put down dry boards. Tape tester leads to wood sticks to keep hands away from power. Use non-contact voltage tester before touching wires. Never touch or lean into any made of metal. Remove metal objects from pockets. Do not use oxygen or fuel accelerants in same room as electrical repairs Resource: Basic house wiring |
120 volt 15 amp devices
including GFCI, timers, switches, plugs, wifi controls etc can be
installed on 15 or 20
amp
breaker. 120 volt GFCI, outlet, receptacle that is rated 20 amp can be installed on 20 amp breaker only, but NOT on 15 amp breaker. Buy 15 amp GFCI 20 amp GFCI |
Use outlet tester to check for correct wiring on any 120 volt straight-blade outlet. Buy: Klein testers Outlet tester Circuit breaker finder Electric usage monitor |
Weatherproof
lever switch on outdoor lights Safely operate outdoor toggle switch Replaces outdoor cover Install over top of ordinary switch Works with single-pole, double-pole, 3PST, 3-way, 4-way switches etc Use weatherproof box for outdoor Can be used indoor or outdoor Buy: Cantex lever switch Leviton lever switch Outdoor lever switches at Amazon Resource Cantex-toggle-switch-covers.pdf Cantex-PVC-junction-boxes.pdf |
Electrical tools must be insulated. Always best to disconnect power, but insulation failure, lack of proper grounding, grounded neutral, lack of GFCI, out-of-code wiring, generator operating without transfer switch, and other problems still pose a risk to anyone working on electric power ... even when breaker is off. Buy: Electrician tools kits KLEIN TOOLS Tools kits IRWIN tools KNIPEX |
Use nipper instead of pliers or screwdriver for removing staples (and nails). Do not damage cable or wires inside cable. Code -Cable SHALL BE secured without damage to the outer covering. NEC sec. 336-15 Buy End cutting nippers at Amazon Wire strippers at Amazon Linesman pliers Pro linesman plier Needle nose pliers |
6" Pull box Junction boxes for conduit and wiring Buy: Bud industries 6x6x4 best value/ no KO Raco 6x6x4 metal pull box Wiegman 6x6x4 pull box Hoffman 6x6x4 pull box Adamax raintight enclosure Raintight 6x6x4 box Pull boxes Buy: Pull boxes Polycarbonite boxes Resource: Enclosures and boxes |
Electrical devices, boxes, wires, conduit etc must be attached firmly to structure, or as image shows, the Sonoff is attached to a din rail that is screwed into a plastic enclosure. Wires must be attached so they cannot move or be impacted by activity. Enclosing Sonoff inside a plastic box may impede wireless connection. Maybe using a simple wifi or zwave switch mounted inside ordinary switch box might be better solution, but not offer identical wiring options. Buy from my affiliate links: Sonoff 4 channel pro Sonoff |
Sonoff controls 2 Jandy actuators Buy from my affiliate links: Sonoff 4 channel pro Sonoff 24 VAC transformer Jandy actuator valve |
Sonoff controls Intermatic P4043ME Control 2 Intermatic PE24VA valve actuators Buy from my affiliate links: Intermatic PE24VA Sonoff 4 channel pro Sonoff Jandy actuator valve |
Sonoff controls 2 speed pump 40 amp relay & contactor = 5 Hp @ 240 volt Buy from my affiliate links: Buy 40 amp contactor with 120 volt coil 40 Amp DPDT relay at Amazon Magnecraft box and cover Magnecraft w199 relays Siemens power relays Schneider W199 relay NTE open frame relays Contactors/ reliable for heavy amp loads 15 amp Relays for loads up to 10 amps Resources: Wire size and amp charts for motors Information on contactors |
Larger image 9-3 ⁄8" x 5-1 ⁄2" x 3-5 ⁄8" Enclosures can be used for timers or for other electrical for electrical control center... Shown are several devices mounted to din rail. The din rail must be firmly attached to enclosure. Delay timers will fit if mounted directly to metal box, and not din rail. Note that the
LY2-LY3 15 amp relays are rated 10 amps for 2 and 3-pole relays. And 5
amps for LY4 4-pole relay.
Buy:2T511GA Nema3R enclosure at Amazon 10 amp Relays 10 amp LY2 relays LY3 relay 120 volt LY2 15 amp Din rail timer Din rail Fuseholder Resources: Din rail timers Off Delay timers On delay timers Build 3-phase astronomic timer Build 2-speed timer for pump, motor etc |
|
Larger image Another image Contactor, open-frame relay, and small relay with base will fit into Intermatic metal and plastic enclosures, but not the smaller Grasslin enclosures. Note that a 30 amp
power relay, or switch, or contactor has safe maximum
80% rated value, or 24 amps. For 30 amp circuit, must use 600 volt, 10
gauge solid copper wire. Never undersize wire or use extension cord for
permanent wiring.
Buy: 2T511GA Nema3R enclosure at Amazon Siemens 30 amp power relay 30-40 amp Contactors Resources: Contactors and relays How to wire open frame relay Build a 2-speed motor control |
Altelix Nema3R polycarbonate indoor-outdoor 1/2 3/4 KO on bottom of enclosure Buy: Altelix enclosures 12x8x4 Polycarbonate Polycarbonate enclosures Honeywell enclosures |
Fiberglass enclosures/ for durability/ indoor/outdoor With aluminum mounting plate Buy: Fiberglasss enclosures Tapered drill bit 1/4"-1-3/8 holes Fish bit Resources Delay timer wiring Contactors |
Use only 600 volt wire. Lamp cord, extension cords are not rated 600 volt. Use copper wire only. Aluminum wire is fire risk and should be avoided or installed by professional. 30 amp breaker use 10 gauge / 120-240 volt 30 amp outlet can be installed on 30 amp breaker only/ use 10 gauge wire ... cannot be connected to 15-20-40 amp breaker. Orange/ #10 gauge wire, with ground ... 30 amp capacity. Safe maximum: 30 x 80% = 24 amps. Buy: 10-2 gauge/ 30 amp 10-3/ 30 amp Southwire electric tools |
Yellow
12 gauge 20 amp 120 volt 20 amp outlet can be installed on 20 amp breaker, but not 15 amp breaker/ use 12 ga wire. ... cannot be connected to 30-40 amp breaker. 1 Yellow/ #12 gauge wire, with ground ... 20 amp capacity. Safe maximum 16 amps. Buy: 12-2 gauge/ 20 amp 12-3/ 20 amp NMB is house wiring UF is underground Rolls of stranded wire HOOK UP Wires |
50-60
amp breaker use 6 gauge / 240 volt 50 outlet can be installed on 50 amp breaker only Buy: 6-2 wire Southwire electric tools NMB is house wiring UF is underground |
40-50
amp breaker use 8 gauge / 240 volt 40 amp outlet can be installed on 40 or 50 amp breaker only Buy: 8-2 wire Southwire electric tools NMB is house wiring UF is underground |
GFCI circuit breaker A GFCI circuit breaker will protect all boxes on circuit. Circuit must be grounded. Ground wire must be continuous and connected to each piece of equipment. White wire on circuit breaker must be connected to Neutral busbar inside the breaker panel. Buy GFCI circuit breakers |
Push down 1" wide Push down breaker Plug-in breaker Buy single-pole: Choose from 15 to 60 amp Eaton CL series Siemens 15-60 amp Single-pole tandem breaker Tandem breakers 2" wide Push down breaker Plug-in breakers Buy double-pole: Choose from 15 to 125 amp Choose from 15 amp to 200 amp Eaton CL series circuit breaker Siemens circuit breaker Double pole GFCI |
Solid copper wire only Larger image Both wires MUST be same gauge Straighten each wire Tighten screw very tight against copper wire |
Larger image Connect stranded and solid with wire connector and run jumper to screw plate. See example image |
Buy
from my affiliate links every time/ thanks: Amazon ''As an Amazon Associate I earn from qualifying purchases'' Enter Amazon from any link on my site, fill cart with any item ... purchases pay small commission E-mail: geno03245w@gmail.com My response might end up in spam folder, check email folders Waterheatertimer on Twitter Message thru facebook |